BOT-R3X WiFi Wireless Boiler Thermostat Manual
Application
The wireless intelligent one-to-one digital thermostat is a temperature controller suitable for underfloor heating systems. By comparing the ambient temperature with the set temperature, it controls the working status of the gas wall mounted boiler and the electric valve in the underfloor heating system to achieve the goals of regulating ambient temperature, comfort, and energy conservation.
Electrical Specifications
Equipment power supply | 3x1.5V alkaline AAA batteries |
---|---|
Protection grade | IP20 |
Temperature sensor | NTC |
Temperature Accuracy | ±0.5°C (adjustable) |
Self consumption power | <170uA |
LOAD | 3A (resistive) |
Operating Instructions
Power On/Off: Press the power on/off button once to turn on the machine; press it again to turn off the machine, and simultaneously close all the valves.
Mode Conversion Key (M): When the device is powered on, press the M key to switch the working mode. The liquid crystal display indicates manual mode ⚙️, and indicates the "away from home" mode ?. (For the online version, you can set the automatic mode on your mobile device) The liquid crystal display indicates automatic mode ?.
Temporary Mode: When the device is powered on, click the [temp adjust] button. If it is in automatic mode, it will switch to the temporary mode. You can directly adjust the set temperature. The default temperature for the "away from home" mode is 16°C.
Adjustment Keys (▲/▼): When the device is turned on, press the ▲ or ▼ keys to adjust the temperature and other parameters.
Child Lock Function: Press and hold the ▲ and ▼ keys for 5 seconds while the device is turned on. When the panel enters the lock key state, a lock icon ? appears on the right side of the display screen, indicating that the lock key has been successfully pressed.
Unlock: Press and hold the ▲ and ▼ keys for 5 seconds to unlock the child lock on the panel.
Device Icon Description
The following icons may appear on the device display:
- ? WiFi icon
- 22.5 Real-time temperature display
- SET 22.5 Set temperature display
- ON/OFF Power on/off button
- M Mode key
- ? Leaving home mode icon
- ⚙️ Manual mode icon
- ? Automatic mode icon
- ? Child lock icon
- ? Heating icon
- ❄️ Cooling icon
- ? Device battery icon
Advanced Device Options Settings
When the device is powered off, press and hold the M key to enter the advanced option settings. After entering, press the M key to switch to the next item, and use the ▲ or ▼ keys to make adjustments.
Advanced parameter settings for equipment
Parameter | Default Value | Parameter Function |
---|---|---|
1. Temperature compensation | 0 | Temperature compensation range: -9.9~9.9°C |
2. Temperature display difference | 0.5 | Temperature difference startup range: 0.5~10°C |
3. Manual mode | ON | Turn on/off the device's antifreeze function |
4. Set the upper temperature limit value | 35°C | Adjustable range: 15°C~60°C |
5. Key sound | ON | Turn on/off device button sound |
6. Cooling/Heating | * Cooling/Heating * | Set to Cooling or Heating mode |
7. Restore device factory settings | --- | Press the M key to adjust the display to "---", then press the confirm key to restore factory settings. |
Low-temperature protection function
The thermostat is in the off state. When the indoor temperature drops below 5 degrees Celsius, the thermostat will automatically turn on the heating ? function. When the indoor temperature rises to 7 degrees Celsius, the thermostat will automatically turn off the heating.
Details of Daily Programming Mode
The network programming mode needs to be operated on the APP, working in six cycles per day. (Single machine version without programming function)
Serial Number | Time Slot | Set Temperature |
---|---|---|
1 | 06:00 | 20°C |
2 | 08:00 | 16°C |
3 | 11:30 | 16°C |
4 | 12:30 | 16°C |
5 | 17:00 | 22°C |
6 | 22:00 | 16°C |
Device code connection settings
1. In the power on state, long press the Code key on the receiving panel until its signal light starts flashing.
2. In the power on state, long press the ▲ key on the transmission panel until the signal light on the reception panel stops flashing.
3. When the device is in heating mode ?, adjust the set temperature to be higher than room temperature. At this time, all three indicator lights on the output signal receiving panel will light up and successfully match the code ✔️.
Device network connection settings
Open the Tuya Smart/Smart Life app ?. Find the temperature controller product (Bluetooth+WIFI model) in the (small household appliances) device list. Under the designated distribution mode, click the confirmation button on the page, select the 2.4 ghz WIFI that can connect to the Internet in the device work area and enter the WIFI password. Click Next, click "Connect" according to the page prompts, find the prompt content as instructed, click "Prompt content", and then return to the graffiti APP to enter the distribution process.
When the temperature controller transmitter panel is turned on, press and hold the ▲ key for 5 seconds until the ? icon flashes on the temperature controller display screen, and the temperature controller enters the connected state.
Wiring Diagram
Caution: Please do not connect wires with electricity, so do not expose the wire ends!
The diagram shows connections for an AC220V power plug cable and a wall-mounted boiler signal line. It indicates terminals L (Live), N (Neutral), M (Motor/Pump), NO (Normally Open), COM (Common), NC (Normally Closed), NO1, and NC1. The instructions specify connections for normally closed electric actuators (NO1 to N), normally open electric actuators (NC1 to N), and external circulation pumps (M to N). It also notes that distinction between positive and negative colors is not required for the boiler signal line. Installation must be carried out by professionals due to high voltage.
Wiring Terminal Instructions:
- NO1: Normally closed electric actuator - Connect NO1 and N
- NC1: Normally open electric actuator - Connect NC1 and N
- M: External circulation pump <5A - Connect M and N
Installation Steps
The installation involves several steps, visually represented by diagrams:
- Panel Preparation: Gently pry open the front panel.
- Backplate Installation: Install expansion screw sleeves (e.g., with a spacing of 59mm) on the wall. Place the backplate in the installation position and insert and tighten the screws.
- Connecting Plate: Insert the connecting plate into the square bracket.
- Wire Connection: Connect the wires according to the wiring diagram.
- Mounting the Transmitter: Insert the transmitter panel into the bracket.
- Final Assembly: Cover the panel and complete the installation. The device can then be placed on a desktop or other surface.
Diagrams show:
- Removing the front panel.
- Installing wall anchors and screwing the backplate.
- Connecting the transmitter panel to the bracket.
- Final placement of the device.