DOD Gunslinger MOSFET Distortion
Model: [HRV]
A high-gain MOSFET distortion pedal designed for guitarists and bassists.
Product Overview
The DOD Gunslinger MOSFET Distortion is a versatile effects pedal designed to deliver powerful distortion tones. Its intuitive controls allow for precise shaping of gain, level, and EQ, making it suitable for a wide range of musical styles.
Controls and Features
The pedal features the following controls:
- 1. GAIN: Adjusts the amount of distortion applied to the signal.
- 2. LEVEL: Sets the overall output volume of the distorted signal.
- 3. LOW: Controls the amount of low frequencies in the distortion tone.
- 4. HIGH: Controls the amount of high frequencies in the distortion tone.
- 5. INPUT: Connect your instrument here.
- 6. FOOTSWITCH: Engages or disengages the effect.
- 7. LED: Indicates when the effect is active (illuminates).
- 8. OUTPUT: Connect to the input of your amplifier or the next effects pedal in your signal chain.
Specifications
- Input Impedance: 1/4" TS Unbalanced - 470 kΩ
- Output Impedance: 1/4" TS Unbalanced - 100 Ω
- Current Draw: 20 mA
- Bypass Type: True Bypass
- Power Requirements: 9VDC alkaline battery (not included) or a 9VDC/18VDC negative center tip power adapter (PS0913DC or compatible).
- Warranty: 1 Year
Usage Recommendations
Many guitarists and bassists prefer placing the Gunslinger at the beginning of their effects chain. A typical signal chain order often includes distortion effects first, followed by modulation effects (like Chorus, Flanger, Phaser, Tremolo), and finally time-based effects (like Delay and Reverb). Positioning the Gunslinger early in the chain helps preserve its unique character regardless of the pedals that follow. Experimenting with different positions in your setup is encouraged to find the optimal sound.
Safety and Compliance
Please read and follow all safety instructions to ensure safe operation and prevent damage.
- General Warnings: This unit is equipped with symbols indicating potential hazards. The lightning bolt symbol [Electrical Hazard Symbol] ⚡️ signifies dangerous voltages within the unit. The exclamation mark in a triangle [Warning Symbol] ⚠️ indicates that the user should consult the accompanying manual. The "Do Not Open" symbol [Do Not Open Symbol] ?? warns against opening the unit, as there are no user-serviceable parts inside. All servicing should be performed by qualified personnel. Opening the unit for any reason will void the manufacturer's warranty.
- Environmental Precautions: Do not expose the unit to rain or moisture. If liquid is spilled on the unit, unplug it immediately and seek service from your dealer. Unplug the unit during electrical storms to prevent damage. This product is intended for use at altitudes up to 2000 meters (approximately 6562 feet); do not use it above this altitude.
- Cleaning: Clean only with a dry cloth.
- Ventilation: Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
- Heat Sources: Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Accessories: Use only attachments and accessories specified by the manufacturer.
UK Mains Plug Safety
If your unit is equipped with a UK mains plug:
- Discard any cut-off UK mains plug; it is unsafe.
- Never insert a damaged or cut mains plug into a 13 Amp socket.
- Do not use the mains plug without its fuse cover. Replacement fuse covers can be obtained from your local dealer. Replacement fuses must be 13 Amp and ASTA approved to BS1362.
Disposal of Product
Do not mix this product with general household waste. There is a separate collection system for used electronic products in accordance with legislation requiring proper treatment, recovery, and recycling. Households in 25 EU member states, Switzerland, and Norway can return their used electronic products free of charge to designated collection points or to the retailer (if purchasing a similar new product). For countries not listed above, please contact your local authorities for the correct disposal method. This ensures that your waste product undergoes the necessary treatment, recovery, and recycling, thereby preventing potential negative effects on the environment and human health. [Recycling Symbol] ♻️
Electrical Safety and Wiring
Important Safety Instructions:
- Unplug this apparatus during electrical storms or when not in use for long periods.
- Do not disregard the safety purpose of a polarized or grounded plug. A polarized plug has two blades, one wider than the other. A grounded plug has two blades and a third grounding pin. The wide blade or third pin is for your safety. If the supplied plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power-supply cord from being walked on or pinched, especially at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When using a cart, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- The power switch used in this equipment does not disconnect the mains supply.
- For rack or permanent installation where the plug is inaccessible, a mains switch with a contact separation of at least 3 mm in all poles must be incorporated into the electrical installation of the rack or building.
- If connected to a 240V supply, an appropriate CSA/UL certified power cord must be used for this supply.
Mains Lead Wiring Code
NOTICE TO CUSTOMER IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.
WARNING: THIS APPARATUS MUST BE CONNECTED TO A MAINS SOCKET OUTLET WITH PROTECTIVE EARTHING.
The conductors in the mains lead are colored in accordance with the following code:
GREEN AND YELLOW – EARTH / BLUE – NEUTRAL / BROWN – LIVE
Because the colors of the conductors in the mains lead of this apparatus may not correspond with the colored markings identifying the terminals in your plug, proceed as follows:
- The conductor colored GREEN AND YELLOW must be connected to the terminal in the plug marked with the letter E ?, or by the earth symbol, or colored GREEN or GREEN AND YELLOW.
- The conductor colored BLUE must be connected to the terminal marked with the letter N or colored BLACK.
- The conductor colored BROWN must be connected to the terminal marked with the letter L or colored RED.
This equipment may require the use of a different type of mains lead, plug, or both, depending on the available power supply at the installation location. If a plug needs to be changed, have it replaced by qualified service personnel. The GREEN/YELLOW wire will be connected directly to the chassis of the unit.
CONDUCTOR | WIRE COLOR (Normal) | WIRE COLOR (Alt) |
---|---|---|
L (LIVE) | BROWN | BLACK |
N (NEUTRAL) | BLUE | WHITE |
E (EARTH GND) | GREEN/YEL | GREEN |
WARNING: IF PROPERLY GROUNDED, A FAULT IN THE UNIT OR SYSTEM TO WHICH IT IS CONNECTED MAY RESULT IN A VOLTAGE ON THE CHASSIS. SEVERE INJURY OR DEATH CAN OCCUR IF THE CHASSIS AND GROUND ARE TOUCHED SIMULTANEOUSLY.