Fujitsu Split Type Air Conditioner

CASSETTE type (50Hz)

Models

Indoor unit: AUY36TLB3W, AUY45TLB3W

Outdoor unit: AOY36TPB3L, AOY45TPB3L

CONTENTS

SPECIFICATIONS

TYPECooling & heatingAUY36TLB3WAUY45TLB3W
INAUY36TLB3WAUY45TLB3W
OUTAOY36TPB3LAOY45TPB3L
COOLING CAPACITY10.3 kW - 10.5 kW12.4 kW - 12.7 kW
HEATING CAPACITY10.8 kW - 11.0 kW14.0 kW - 14.3 kW
POWER SOURCE380 V - 415 V380 V - 415 V
3 / 50 Hz3 / 50 Hz
RUNNING CURRENTCOOL6.9 A - 6.8 A8.2 A - 8.4 A
HEAT6.5 A - 6.3 A9.0 A - 9.0 A
INPUT WATTSCOOL4.00 kW - 4.04 kW4.55 kW - 4.60 kW
HEAT3.68 kW - 3.65 kW5.05 kW - 5.05 kW
E.E.RCOOL2.58 - 2.60 kW/kW2.73 - 2.76 kW/kW
HEAT2.93 - 3.01 kW/kW2.77 - 2.83 kW/kW
MOISTURE REMOVAL5.0 L/h6.0 L/h

FAN

HIGHMEDLOWOUTDOOR UNIT
INDOOR FAN SPEED580 r.p.m.500 r.p.m.420 r.p.m.770 r.p.m.
OUTDOOR FAN SPEED770 r.p.m.
INDOOR AIR FLOW1,500 m3/h1,650 m3/h
OUTDOOR AIR FLOW6,000 m3/h5,600 m3/h

MEASUREMENT

INDOOR UNITOUTDOOR UNIT
DIMENSIONS H x W x D296 x 830 x 830 mm1,152 x 940 x 370 mm
GRILLE35 x 940 x 940 mm
WEIGHTINDOOR UNIT: 40 kgOUTDOOR UNIT: 53 kg
Net / GrossOUTDOOR UNIT: 100 kg / 114 kg110 kg / 124 kg

COMPRESSOR AND REFRIGERANT

TYPEDISCRIMINATIONSTANDARD REFRIGERANTREFRIGERANT
Hermetic type, 2 pole, Three phase, Induction motor, ScrollZR48K3E-TFD-501ZR61KCE-TFD-599
2,600 g3,500 gR407C
MAX PIPE LENGTH50 m50 m
MAX PIPE HEIGHT30 m30 m
FULL CHARGEPipe length20 m2,600 g3,500 g
30 m2,900 g3,800 g
40 m3,200 g4,100 g
50 m3,500 g4,400 g
ADDITIONAL CHARGE30 g/m30 g/m

OUTLINE AND DIMENSIONS

INDOOR UNIT (Unit: mm)

A diagram showing the dimensions of the indoor unit. Key dimensions include height (296 mm), width (830 mm), and depth (830 mm). The grille dimensions are 35 x 940 x 940 mm. Pipe connections for large and small pipes are indicated, along with drain pipe dimensions.

OUTDOOR UNIT (Unit: mm)

A diagram showing the dimensions of the outdoor unit. Key dimensions include height (1,152 mm), width (940 mm), and depth (370 mm). The diagram shows the front and side views of the unit.

REFRIGERANT SYSTEM DIAGRAM

Diagrams illustrating the refrigerant flow for both cooling and heating modes for the AUY36TLB3W / AOY36TPB3L and AUY45TLB3W / AOY45TPB3L models. The diagrams show the outdoor unit components (condenser, compressor, accumulator, dryer, expansion valve, strainer, muffler, 4-way valve, high pressure switch, charging valve) and the indoor unit component (evaporator). Refrigerant pipe sizes are indicated: $19.05$mm ($3/4"$) and $9.53$mm ($3/8"$).

CIRCUIT DIAGRAM

Circuit diagrams for both the indoor and outdoor units. These diagrams detail the electrical connections, including components like control boards, fan motors, compressors, thermistors, switches, and power supply connections.

INDOOR PCB CIRCUIT DIAGRAM

A detailed circuit diagram of the indoor unit's Printed Circuit Board (PCB). It shows the layout of components, integrated circuits (ICs), resistors, capacitors, transistors, and connectors, along with their respective part numbers and values.

OUTDOOR PCB CIRCUIT DIAGRAM

A detailed circuit diagram of the outdoor unit's Printed Circuit Board (PCB). Similar to the indoor PCB diagram, it illustrates the electronic components and their interconnections.

ERROR CONTENTS

1. REMOTE CONTROLLER

Instructions for diagnosing errors using the remote controller. When an error occurs, the "EE" indicator blinks. Pressing the "SET TIME" and "TEMP./DAY" buttons simultaneously for over three seconds initiates a self-diagnosis check, displaying error codes (E:00 to E:14) on the current time display.

Table 1: Error Codes

Error cordError contents
E:00Communication error (indoor unit → remote controller)
E:01Communication error (indoor unit → outdoor unit)
E:02Room temperature sensor open
E:03Room temperature sensor shortcircuited
E:04Indoor heat exchanger temperature sensor open
E:05Indoor heat exchanger temperature sensor shortcircuited
E:06Outdoor heat exchanger temperature sensor open
E:07Outdoor heat exchanger temperature sensor shortcircuited
E:08Power source connection error
E:09Float switch operated
E:0AOutdoor temperature sensor open
E:0BOutdoor temperature sensor shortcircuited
E:0CDischarge pipe temperature sensor open
E:0DDischarge pipe temperature sensor shortcircuited
E:0EOutdoor high pressure abnormal
E:0FDischarge pipe temperature abnormal
E:11Model abnormal
E:12Indoor fan abnormal
E:13Outdoor signal abnormal
E:14Outdoor EEPROM abnormal

Test Running: Press START/STOP to stop. Refer to the operating manual for operation checks. Ensure no abnormal sounds or vibrations during test running.

2. OUTDOOR UNIT

When outdoor temperature drops, outdoor unit fans may switch to low speed or stop intermittently.

ERROR: Heat & Cool model (Reverse cycle) only

LED lamps on the outdoor unit board indicate error status as per Table 2.

Table 2: Error LED Status

Error contentsLED1LED2LED3LED4LED5LED6
Signal abnormalXOXXOX
Indoor unit abnormalXXOXOX
Discharge pipe temperature abnormalXXXOXO
Outdoor heat exchanger temperature abnormalXXOOXO
Outdoor temperature abnormalXOXOXO
Power source connection errorOXXXOO
EEPROM abnormalOOOOOO
Outdoor high pressure abnormalO-----
Discharge pipe temperature abnormal-O----

LED Status Key:

When the fault is cleared, the LED lamp goes off. For discharge pipe temperature abnormal and high pressure abnormal, the LED lamp lights continuously for 24 hours as long as power is not turned off.

ERROR LED DISPLAY LAYOUT A diagram showing the layout of LEDs on the outdoor unit board.

DISASSEMBLY ILLUSTRATION

Exploded view diagrams illustrating the disassembly process for both the indoor and outdoor units. These diagrams show the various components and their assembly order, with reference numbers for each part.

PARTS LIST

Detailed parts lists for both the indoor and outdoor units. Each part is listed with its reference number, description, and corresponding part number.

Indoor Unit Parts List Excerpt:

Ref.DescriptionPart number
34Capacitor (Fan Motor)9703306068
47-1Rubber (Discha. Pipe)313194159807
61Decoration Plate9362787000
67Rubber (Vibration Proof)9362783002
71Grille Hook Holder9362782005
93Filter9362766005
117-3Hex. Nut w/Spring Washer301721180114
122Louver Support Holder9362799003
127Drain Hose9362784009
138Separate Wall9362737005
143-1Clamp NK-3N313361274700
143-3Clamp NK-9N313209399700
146-1Evaporator-A Assy9364804002
146-2Evaporator-B Assy9364805009
155Special Nut M69307615016
160Drain Pan Assy9362804004
164Fan Motor Assy-IN9600878019
168Cabinet-E9362735001
184-1Thermo. Spring-A313728262708
187Clamp No. 1219313361271706
195Clamp SKB-100313361275805
196Clamp SKB-150313035356905
197Wind Guide Board9363117004
223Control Box9362762007
226Motor Gear9362764001
234Thermistor Assy-Room9703299025
235Thermistor Assy-Pipe9703297014
236Controller PCB Assy (for 36)9704557421
236Controller PCB Assy (for 45)9704557438
240Remote Control Unit9371438016
244Pipe Cover9362748001
245Cable Clamp313714181904
337-1Reinforcement (Eva.)-A9362749008
337-2Reinforcement (Eva.)-B9362750004
338Motor Holder9362765008
381Locking Spacer313209391506
457Reinforcement (Drain Pan)9362757003
460-1Pump Cover-A9362775007
460-2Pump Cover-B9362776004
462Top Cover Plate9362806015
464Cabinet-A9362800013
465Cabinet-B9362801010
467Drain Port9362786003
468Special Nut-A (Large)313005446653
469Special Nut-B (Small)313005446759
472-1Grille Reinforcement-A9362738002
472-2Grille Reinforcement-B9362739009
472-3Grille Reinforcement-C9362740005
472-4Grille Reinforcement-D9362741002
472-5Grille Reinforcement-E9362742009
474Turbo Fan Assy9362803014
476-2Special Washer9362756006
477Bellmouth (B)9362774000
479Float Switch9703285004
481Insulation (Grill) A9362780001
481-1Insulation (Grill) B9362781008
482Pump Unit9703125010
484Hook9362736008
487Grille Hinge Wire9362754002
488Drain Pan Plug313005174654
514Control Box Cover9362763004
522Joint Gear9362772006
540Bypath Pipe-B9363152005
541Terminal Plate9363642001
542Panel Base9362759014
543Panel Frame Holder9362761017
544Panel Base Holder9362760010
545Panel Frame9362758017
563Insulation (Inner Box)9362768009
564Bypath Pipe-A Assy9363151008
565Evaporator Holder Assy9362802017
568Noise Insulation9363143003
628Locking Spacer-B313005446558
652-1Thermistor Holder Pipe313806262805
690Joint-A9362773003
692Joint Shaft9362771009
705Louver9362769013
710Intake Grille9362767019
735Distributor Assy9364795003
777-1Grille Hook-A9362779012
777-2Grille Hook-B9362778015
798Pump Hook Bracket9362753005
803Cabinet-D9362734004
814Cabinet-C9362733007
815-1Terminal 3P9306489052
815-2Terminal 3P9703345012
834-1Wire Cover-A9362789004
834-2Wire Cover-B9362788007
835Cushion Rubber (Pump)9362777001
847Louver Supporter9362770019
858Grille Spring9362755009
875Filter PCB Assy9704561091
876-2Step Motor9360307019
897Coupling Pipe-A Assy9363153002
898Coupling Pipe-B Assy9364806006
982-1Cord Clamp9356857009

Outdoor Unit Parts List Excerpt:

Ref.DescriptionAOY36TPB3L Part No.AOY45TPB3L Part No.
2Fan Cover93521590159352159015
4Emblem-Rear9351355005---
5Cabinet-A, Painted93521460159352146015
6Cabinet-C, Painted93521490169352149016
9Cabinet-B, Painted93521470129352147012
12Base Assy, Painted93521360169352136016
15Dryer93699780439369978043
16-1Condenser-A Assy93683560029368409005
16-2Condenser-B Assy93683530019368536008
18Suction Pipe Assy93709480289364514000
20Discharge Pipe-A Assy9370950021---
21Discharge Pipe-B Assy93683470009368331009
26Compressor Cover-A93640880069364088006
29Separate Wall93552770139355277013
30Blower Cover, Painted93521510199352151019
32Control Box Metal93521340129352134012
34Capacitor (Fan Motor)93579650249357965024
36Cord Holder Metal93569340079356934007
39Propeller Fan Assy93663780139366378013
41Fan Motor Assy-Out96008320289600832028
45Bracket (Motor) Assy93681080079368108007
46Compressor Assy93707720129367376001
48Bracket (Coupler) Assy93552810109355281010
55Special Nut M8 (For Comp.)93550910089355091008
107Rubber Seat-A (For Comp.)93640840089364084008
108Sleeve-A (For Comp.)93640850059364085005
109Terminal Cover (For Comp.)93640870099364087009
111Terminal Packing93640860029364086002
182Clamp No.149313361271505313361271505
184-1Thermo. Spring-A313728262708313728262708
185Rubber Bushing313005066051313005066051
236Controller PCB Assy97047641199704764126
272Strainer Assy93683430029368343002
300Suction Pipe-C9368350000---
327Suction Pipe-A9368348007---
330Inlet Pipe (Cond.)-A9368334000---
333Accumulator93503630189350363018
333-2Accumulator (B)93684630079368463007
334Suction Pipe-B93625570099362557009
343Solenoid Coil93596161089359616108
3444-Way Valve9353055002---
344-24-Way Valve9353532008---
354Pressure Switch97036670089704045003
373Grip93521570049352157004
381Locking Spacer313209391506313209391506
405Clamp No.1763313816345304313816345304
407Clip (Cable) No.1259313739340109313739340109
450Discharge Pipe-A9368338008---
527Protection Net93521630129352163012
575Condensing Pipe-C93685350019368535001
620Inlet Pipe (Cond.) Assy93683550059362532006
628Locking Spacer313005446558313005446558
646Compressor Cover-B93640890039364089003
653-1Bolt (Fan Motor Fixing)93850890209385089020
734Cabinet Top Plate93521610189352161018
735Distributor Assy93683520049362533003
790-1Belt Heater-A93611400669361140042
791Magnetic Relay99000780109900078010
803Cabinet-D, Painted93521500129352150012
805Blower Cover Corner93521600119352160011
806Cond. Pass Pipe-A Assy9368351007---
807Cond. Pass Pipe-B9368360009---
808Inlet Pipe (Accumulator)-A93683490049368341008
809Ball Valve-A93717990189371799018
810Ball Valve-B93717990329371799032
813Cabinet Hook93521480029352148002
815-2Terminal-8P93632760229363276022
816Wire Clamp Metal313584219902313584219902
819Valve-A Coupl. Pipe93683420059368342005
821Joint Pipe (Valve-B)93640800009368340001
822Fan Cover Fixture-A93521580189352158018
825Expansion Valve Assy93683640079368363000
826Condensing Pipe-B93683540089368335007
842Cond. Pass Pipe-C9368361006---
857Inlet Pipe (Accumulator)-B---9368333003
862Valve-B Coupl. Pipe9368332006---
880-1Network97009870179700987017
918Thermistor Assy99001290199900129019
919Expansion Valve Coil93634670179363467017

STANDARD ACCESSORIES

This section lists the standard accessories included with the indoor and outdoor units, along with their part numbers.

INDOOR UNIT ACCESSORIES

Name and ShapePart No.
Coupler heat insulation9350716029
9352766015
Remote control unit cord clamp313714181904
Binder313035356905 (Large)
313361275805 (Small)
Screw(A) 301141134166
(B) 301141153027
Special nut A (large flange)313005446653
Special nut B (small flange)313005446759
Remote control unit9371438016
Template9363173000
Blower cover insulation9363265002
Hook wire9363168006

OUTDOOR UNIT ACCESSORIES

Name and ShapePart No.
Power cap9352173011
Auxiliary pipe assembly9355292016
Edge cover9352436000
Tapping screw301463040100
Binder313035356905
Putty303020200114
Coupler heat insulation313005074759
Pipe (drain)313728031005
Flexible tube313013042915
Cap (drain)313166024302
Models: AUY36TLB3W, AUY45TLB3W, AOY36TPB3L, AOY45TPB3L, AUY36TLB3W Split Type Air Conditioner, Split Type Air Conditioner, Type Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 20 Pages, 1.78MB

PDF preview unavailable. Download the PDF instead.

auy36tlb3w-aoy36tpb3l-auy45tlb3w-aoy45tpb3l-service-manual-fujitsu-general compr iLovePDF

Related Documents

Preview Fujitsu ASYA12LCC AOYR12LCC Split Type Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type, wall-mounted room air conditioners, models ASYA12LCC and AOYR12LCC. Includes specifications, diagrams, error codes, disassembly instructions, parts lists, and accessories.
Preview Fujitsu Split Type Air Conditioner Cassette Type Service Manual
Service manual for Fujitsu Split Type Air Conditioner, Cassette Type (50 Hz), including specifications, dimensions, refrigerant system, circuit diagrams, error codes, parts lists, and troubleshooting for indoor and outdoor units.
Preview Fujitsu Split Type Room Air Conditioner Service Manual - ABY45RBA3W, AOY45RPA3L
Comprehensive service manual for Fujitsu Split Type Room Air Conditioner, Ceiling type (50Hz), models ABY45RBA3W and AOY45RPA3L. Covers specifications, diagrams, error codes, disassembly procedures, parts lists, and standard accessories.
Preview Fujitsu ASYG14LECA Room Air Conditioner Service Manual
This service manual provides detailed specifications, dimensions, refrigerant system diagrams, circuit diagrams, error detection codes, and parts lists for the Fujitsu ASYG14LECA Room Air Conditioner (Wall Mounted Type).
Preview Fujitsu Split Type Room Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type room air conditioners, covering models ASYA14LCC, AOYR14LCC, ASYA14LCL, ASYA18LCC, AOYR18LCC, and AOYR18LCL. Includes specifications, diagrams, error codes, and parts lists.
Preview Fujitsu ASYA18LEC / AOYR18LEC Split Type Room Air Conditioner Service Manual
This service manual provides detailed specifications, diagrams, error codes, and parts lists for the Fujitsu ASYA18LEC indoor unit and AOYR18LEC outdoor unit, split-type room air conditioners.
Preview Fujitsu ASYG07LMCE/ASYG09LMCE Wall Mounted Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type wall-mounted air conditioners, models ASYG07LMCE and ASYG09LMCE. Includes specifications, dimensions, refrigerant system diagram, circuit diagrams, error detection codes, and detailed parts lists for both indoor and outdoor units.
Preview Fujitsu ASYG14LMCA / AOYG14LMCA Split Type Room Air Conditioner Service Manual
Comprehensive service manual for the Fujitsu ASYG14LMCA and AOYG14LMCA split type wall-mounted room air conditioners, covering specifications, diagrams, error detection, and parts.