Salus RT510 / RT510RF Programmable Thermostat
Model: RT510 (Wired, electronic thermostat - programmable)
Model: RT510RF (Wireless, electronic thermostat - programmable)
Manufacturer: Salus Limited (a member of the Computime Group)
Importer: QL CONTROLS Sp. z o.o. Sp. k.
Website: www.salus-controls.eu
Introduction
The RT510 and RT510RF are programmable electronic room thermostats designed to control room temperature by activating the heating system. They achieve this by shorting terminal blocks, providing clear feedback on the LCD display. These thermostats offer various operating modes, including automatic (time schedules), manual, frost protection, and holiday mode. For optimal performance, please read this manual carefully before use. Only use AA 1.5 V alkaline batteries; do not use rechargeable batteries. Batteries are housed in a slot located under the cover.
Product Compliance and Safety Information
Product Compliance: This device complies with Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU, and RoHS 2011/65/EU. Full information is available at www.saluslegal.com.
Safety Information: Use the device in accordance with national and EU regulations. Ensure the device is used as intended and kept in dry conditions. This product is for indoor use only. Installation must be performed by a qualified person according to national and EU regulations.
Technical Specifications
Specification | RT510 Thermostat | RT510TX Thermostat | RXRT510 Receiver |
---|---|---|---|
Supply | 2 x AA alkaline batteries | 2 x AA alkaline batteries | 230 V AC |
Rating Max | 3 (1) A | - | 16 (5) A |
Outputs | Voltage free NO/COM/NC terminals | - | Voltage free NO/COM terminals |
Temperature Range | 5-35°C | 5-35°C | - |
Temperature Accuracy | 0.1°C or 0.5°C | 0.1°C or 0.5°C | - |
Control Algorithm | TPI or hysteresis ±0.25°C | TPI or hysteresis ±0.25°C | - |
Radio Frequency | - | 868 MHz | 868 MHz |
Dimension [mm] | 120x96x27 | 120x96x27 | 96x96x27 |
Button Functions
RT510/RT510TX Thermostat Buttons
- 1. Boost function: Activates a temporary higher temperature.
- 2. Manual Mode: Switches to manual temperature control.
- 3. Frost protection / Holiday Mode: Activates frost protection or holiday mode.
- 4. Increase button: Increases temperature setpoint or value.
- 5. Decrease button: Decreases temperature setpoint or value.
Receiver Operation Notes:
- 6. ON (in Manual Mode): Turns the boiler on.
- 7. OFF (in Manual Mode): Turns the boiler off.
- 8. Automatic Mode: Receiver operates according to thermostat settings.
- 9. On/Off Slide Switch: Controls the receiver output.
LCD Icon Description
Icon | Description |
---|---|
1️⃣ | Day of the week |
2️⃣ | Program number |
3️⃣ | Program indicator |
4️⃣ | Settings |
5️⃣ | Temperature measured / set |
6️⃣ | Boost function |
7️⃣ | Low battery status ? |
8️⃣ | Wireless connection with the receiver ? |
9️⃣ | Heating Mode On ? |
? | Manual Mode On ?️ |
1️⃣1️⃣ | Holiday Mode On ✈️ |
1️⃣2️⃣ | Frost Protection Mode On ❄️ |
1️⃣3️⃣ | Temperature unit (°C/°F) |
1️⃣4️⃣ | AM/PM |
1️⃣5️⃣ | Clock ⏰ |
Terminal Descriptions
RT510 Terminals
Terminal | Description |
---|---|
1 - COM | Common Terminal |
2 - NC | Switched Live OFF |
3 - NO | Switched Live ON |
RXRT510 Receiver Terminals
Terminal | Description |
---|---|
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
DIP Switch Settings
The DIP switches on the receiver control the thermostat's operation mode.
- Control Feature TPI: When TPI is selected on DIP switch № 2, DIP switch № 1 is functional. This allows selection between 6 Cycles Per Hour (CPH) for a lower comfort level or 9 CPH for a higher comfort level.
- Span: When Span is selected on DIP switch № 2, DIP switch № 1 is not functional. The SPAN value is fixed at ±0.25°C, recommended for heating devices.
DIP Switch 1: 9CPH / 6CPH (TPI) or ±0.25°C (Span)
DIP Switch 2: TPI / Span selection
Wiring Diagrams
RT510 Wiring Diagram (Wired Thermostat)
This diagram illustrates the connections for the wired RT510 thermostat. A 230V AC power supply (L and N) connects to the RXRT510 receiver's L and N terminals. The receiver's COM and NO terminals connect to the RT510 thermostat's COM and NO terminals, respectively, to control the heating system. The diagram shows the thermostat with its COM, NC, and NO terminals, and the receiver with its COM and NO terminals.
RT510RF Wiring Diagram (Wireless Thermostat)
This diagram shows the connections for the wireless RT510RF system. A 230V AC power supply (L and N) connects to the RXRT510 receiver's L and N terminals. The receiver's COM and NO terminals then connect to the heating system's boiler control terminals. The RT510RF thermostat communicates wirelessly with the receiver. The diagram depicts the RT510TX thermostat and the RXRT510 receiver, with the receiver connected to the 230V AC supply and its output terminals (COM, NO) ready to connect to the heating system.
Setting the Time
Follow these steps to set the current time and date on the thermostat:
- Press and hold the [SELECT] and [SET] buttons simultaneously for 3 seconds.
- Press the [SELECT] or [SET] button to choose the hour format (12-hour or 24-hour). Press [SELECT] to confirm.
- Press the [SELECT] or [SET] button to set the current hour. Press [SELECT] to confirm.
- Press the [SELECT] or [SET] button to set the current minutes. Press [SELECT] to confirm.
- Press the [SELECT] or [SET] button to set the day of the week. Press [SELECT] to confirm.
- Press [SET] to confirm all settings. The thermostat will return to the main screen.
Programming - Automatic Mode
In automatic mode, you can set custom temperature schedules for different times of the day and days of the week. You can choose between a 5-2 day program (different schedules for weekdays and weekends) or a 24-hour program (same schedule every day) via the installer parameter d04. Programmed schedules should cover all time periods.
To start programming:
- Press the [SET] button to enter programming mode.
- Use the [SELECT] or [SET] buttons to choose the day or days of the week from which you want to start programming. Press [SELECT] to confirm.
- Use the [SELECT] or [SET] buttons to set the hour for Program #1. Press [SELECT] to confirm.
- Use the [SELECT] or [SET] buttons to set the minutes for Program #1. Press [SELECT] to confirm.
- Use the [SELECT] or [SET] buttons to set the desired temperature for Program #1. Press [SELECT] to confirm.
- Follow steps 4-9 (setting hour, minutes, temperature) to define Programs #2 through #6.
- Press the [SET] button to finish programming and exit.
Temporary Override Mode
This mode is active only when the thermostat is in automatic (schedule) mode. If you set a new temperature, it will be maintained until the next scheduled time interval begins. The override is automatically cancelled when a new schedule is set.
- While in automatic mode, use the [SELECT] or [SET] buttons to set a new desired temperature.
- The thermostat will automatically return to the main screen and maintain the new setpoint.
To cancel the temporary override before the next scheduled change, you can set a new schedule or turn off the thermostat.
Manual Mode
In manual mode, the thermostat ignores the programmed schedule and maintains the temperature you manually set.
- Press the [Manual Mode] button (indicated by a hand icon ?️) to activate Manual Mode.
- Use the [SELECT] or [SET] buttons to set your desired temperature.
- Press [SET] to confirm. The thermostat will maintain this temperature.
To turn off Manual Mode and return to the programmed schedule, press the [Manual Mode] button again. The hand icon ?️ will disappear from the display.
Hourly Temperature Override Mode (+Hr)
This function allows you to temporarily change the setpoint temperature for a specific number of hours (up to 9 hours), available in both Automatic and Manual modes. After the specified time, the thermostat reverts to its previous mode.
- Press the [+Hr] button. Each press adds one hour to the override duration (up to 9 hours). The display will show the number of hours.
- Use the [SELECT] or [SET] buttons to set the desired override temperature.
- Press [SET] to confirm the override.
Turning off Hourly Override Mode Early: Press the [+Hr] button repeatedly until the number of hours displayed disappears, indicating the override is cancelled.
Frost Protection
This mode maintains a minimum temperature (default 5°C) to prevent pipes from freezing. The temperature can be adjusted in the Installer Mode (parameter d03).
- Press the [Frost Protection] button (indicated by a snowflake icon ❄️) to turn Frost Protection mode ON.
- To turn Frost Protection mode OFF, press the [Frost Protection] button again.
Sleep Mode
Sleep mode pauses all thermostat functions, allowing you to rest without temperature fluctuations.
- Hold the [Boost] and [Manual Mode] buttons simultaneously for 3 seconds to activate Sleep Mode.
- When Sleep Mode is active, all functions are paused.
- Press any button to deactivate Sleep Mode. The thermostat will return to its previous mode.
Holiday Mode
Holiday Mode maintains the frost protection temperature for a specified number of days.
- Hold down the [Holiday Mode] button (indicated by an airplane icon ✈️) for 3 seconds to activate Holiday Mode.
- Use the [SELECT] or [SET] buttons to set the number of days for Holiday Mode (up to 31 days).
- Press [SET] to confirm.
To turn off Holiday Mode, hold down the [Holiday Mode] button for 3 seconds. The airplane icon ✈️ will disappear from the display.
RT510TX Thermostat Pairing with Receiver
Note: If you purchased the RT510RF pack, the thermostat and receiver are pre-paired.
To re-pair a thermostat with a receiver:
- Ensure the receiver is disconnected from power. Set the receiver's switches to AUTO and ON.
- Connect the receiver to power. Wait for the red LED to light steadily.
- Quickly switch the receiver's switch to OFF and then back to ON. A flashing red LED indicates pairing mode has been entered.
- On the thermostat, press and hold the [TEST/PAIRING] button for 3 seconds to begin the pairing process. This may take up to 9 minutes.
- Once paired successfully, the receiver's LED will turn solid red.
- Press and hold the [TEST/PAIRING] button for 3 seconds to end the pairing process.
Testing the Pairing: Press the [TEST/PAIRING] button briefly to check the connection with the receiver. Press it again to return to the main screen.
Installer Mode
Installer mode allows advanced configuration of the thermostat settings.
- Press the [SELECT], [SET], and [TEST/PAIRING] buttons simultaneously for 3 seconds to enter Installer Mode.
- Use the [SELECT] button to cycle through the available parameters (d01, d02, d03, d04).
- Use the [SELECT] or [SET] buttons to set the desired value for the selected parameter.
- Press [SET] to confirm the value.
- To exit Installer Mode, wait 10 seconds without pressing any buttons; the thermostat will automatically return to the main screen.
Installer Parameters
Parameter (dxx) | Function | Setting Range | Default Value |
---|---|---|---|
d01 | Temperature display increments | 0.1°C or 0.5°C | 0.5°C |
d02 | Temperature offset | +/- 3.0°C | 0.0°C |
d03 | Frost Protection setpoint temperature | 5.0°C - 17.0°C | 5.0°C |
d04 | Programmer selection | 5/2 or 24 hr (7d) | 5/2 d |
Reset Procedures
Reset of the RT510 Thermostat
To reset the RT510 thermostat to its factory default settings, press the [RESET] button once. A paper clip can be used to press this button. The thermostat will restart automatically.
Reset of the RT510TX Thermostat
To reset the RT510TX thermostat:
- Remove the batteries without pressing any buttons.
- Wait for 2 minutes.
- Insert the batteries again. The device will restart.
Battery Replacement: The thermostat uses internal memory to back up settings during battery changes. You have approximately 30 seconds to replace the batteries before losing your settings.