Digital Programmable Thermostat
Models: T105, T105RF
Introduction
The T105 / T105RF is a programmable, weekly regulator designed to control room temperature in heating or cooling systems. Before first use, please read this manual carefully. Use only AA 1.5V alkaline batteries. Do not use rechargeable batteries. Batteries are placed in the battery compartment located inside the thermostat.
Product Compliance
This product complies with the following EU Directives: Electromagnetic Compatibility 2004/108/CE, Low Voltage Directive 2006/95/EEC, Directive 93/68/EEC, and 99/5/EC. Full information is available on the website www.saluslegal.com.
Safety Information
Use in accordance with national and EU regulations. Use the device as intended, keeping it in a dry environment. The product is intended for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.
Technical Specifications
Wired Thermostat T105
Parameter | Specification |
---|---|
Power supply | 2 x AA batteries |
Rating max | 5 (3) A |
Outputs | Voltage-free NO/COM relay |
Temperature range | 7-30°C |
Wireless Thermostat T105RF
Parameter | Specification |
---|---|
Thermostat supply | 2 x AA batteries |
Receiver supply | 230 V AC 50 Hz |
Receiver rating max | 16 (5) A |
Receiver outputs | Voltage-free NO/COM relay |
Temperature range | 7-30°C |
Installation and Setup
Thermostat Placement
Choosing the appropriate location for the thermostat is crucial for accurate temperature readings and efficient system operation.
Diagram illustrating proper thermostat placement, showing a wall with a thermostat mounted at a typical height, with callouts indicating minimum clearance from corners and floor.
Opening the Case
To access internal settings and components, the thermostat cover needs to be opened.
Diagram showing a hand gently prying open the front cover of the thermostat to access internal components.
T105RF Wireless Communication
Changing the Communication Code
It is recommended to change the communication code to one other than the factory default to prevent interference from other wireless devices.
Method:
Use DIP switches numbered 1-5 located inside the thermostat.
Procedure:
Set DIP switches randomly, ensuring they are in the same position on both the receiver and the transmitter.
After changing communication codes, reset the regulator by pressing the [RESET button].
User Interface and Controls
LCD Icon Description
- 1. Day of the week indicator
- 2. Clock
- 3. Antifrost Mode indicator
- 4. Low battery indicator
- 5. Temperature unit (°C/°F)
- 6. Measured/Setpoint temperature display
- 7. Program timeline indicator
- 8. Current program number
- 9. Temporary override indicator
- 10. Eco Mode indicator
- 11. Comfort Mode indicator
- 12. Controlled device working status (e.g., boiler on/off)
Button Functions
- 13. [Decrease button]
- 14. [Increase button]
- 15. [Comfort/Economic temperature button]
- 16. [LCD Backlight button]
- 17. [Temperature setpoint button]
- 18. [Weekly programming button]
- 19. [Time set button]
- 20. [Restore factory settings button]
Wiring Diagrams
T105 Wiring Diagram
Diagram showing the wiring for the T105 thermostat. Shows connections to a heating/cooling system via COM and NO terminals, rated for 5(3)A. Power is supplied via AA batteries.
T105RF Wiring Diagram
Diagram showing the wiring for the T105RF wireless system. Shows the thermostat (T105RF) communicating wirelessly with a receiver (RXRT505). The receiver connects to the heating/cooling system via COM and NO terminals, rated for 16(5)A. The receiver is powered by 230V AC.
Operating Modes and Programming
Auto-adapt Function
The auto-adapt function adjusts the operation of the heating device to ensure the comfort temperature is reached at the specified time. This feature activates when the room temperature is lower than the comfort temperature in the upcoming program. The pre-heating duration depends on the current temperature difference; a larger difference means earlier activation. The minimum auto-adapt time is 10 minutes before the programmed program, and the maximum is 50 minutes.
Setting Time
- Press the [Time set button], then use the [Decrease button] or [Increase button] to set the day of the week.
- Press the [Time set button] again, then use the [Decrease button] or [Increase button] to set the hour.
- Press the [Time set button] again, then use the [Decrease button] or [Increase button] to set the minutes.
- Press the [Time set button] or wait 10 seconds to confirm the time setting.
Setting Economic/Comfort Temperature
- Press the [Comfort/Economic temperature button]. Use the [Decrease button] or [Increase button] to select the desired temperature.
- The display will show the currently set comfortable or economic temperature. To change this value, press the [Decrease button] or [Increase button].
- Press the [Comfort/Economic temperature button] or wait 10 seconds to confirm the temperature setting.
Programs
There are 9 programs available. Programs 1-6 are factory-set programs. Programs 7-9 can be defined by the user.
Selecting Factory Programs (1-6)
- Press the [Weekly programming button], then use the [Decrease button] or [Increase button] to choose the programming method for days of the week:
- Each day separately (1, 2, 3, 4, 5, 6 or 7)
- Business days and weekend (5+2)
- Whole week (7)
- Press the [Weekly programming button] again, then use the [Decrease button] or [Increase button] to select program 1-6 for the chosen days.
- Press the [Weekly programming button] to confirm the selection.
Choosing and Programming User Programs (7-9)
- Press the [Weekly programming button], then use the [Decrease button] or [Increase button] to choose the programming method for days of the week (same options as above).
- Press the [Weekly programming button] again, then use the [Decrease button] or [Increase button] to select program 7-9 for the chosen days.
- Press the [Weekly programming button]. Use the [Decrease button] or [Increase button] to adjust the hour, and the [Comfort/Economic temperature button] to assign the comfortable or economic temperature for the specified hour. Repeat for all desired hours.
- Press the [Weekly programming button] to finish defining the program.
Antifrost Mode
Activate Antifrost Mode by simultaneously holding down the [Decrease button] and [Increase button] keys. This mode sets the temperature to 7°C (for heating mode only) and remains active until the next program change. To exit Antifrost Mode, press any key on the thermostat.
Service Parameters
Service parameters can be changed using DIP switches numbered 1-3 located inside the thermostat.
Selecting Heating/Cooling Mode
This is changed by DIP switch #3. When the switch is in the upper position (ON), the thermostat operates in heating mode. When the switch is in the down position (OFF), it operates in cooling mode.
Setting Hysteresis (Span)
Hysteresis (Span) is set using DIP switches #1 and #2. The selectable hysteresis values are presented in the table below:
DIP Switch #1 | DIP Switch #2 | Span |
---|---|---|
ON | ON | 0.4°C |
OFF | ON | 0.8°C |
ON | OFF | 1.4°C |
OFF | OFF | 1.4°C |