Waterdrop WD-G3P600 RO System - Multilingual Product Instruction Manual
1. Parts List
Inspect the package as parts list first. Identify and get familiar with all components for quick installation.
System Housing: 1 Set
WD-G3-CB Filter: X1
WD-G3-CF Filter: X1
WD-G3P600-RO Filter: X1
Smart Digital RO Faucet: x1
White 1/4" PE Tubing: X60" (Preinstalled)
Feed Water Adapter (3/8"-1/2"): 1 Set
White 3/8" PE Tubing: X60" (Preinstalled)
Drain Saddle (1/4"): 1 Set
Red 1/4" PE Tubing: X60"
Lock Clip: X5
Teflon Tape: X1
Power Adapter: 1 Set
Note: If any part is cracked or broken, please do not proceed with the installation and contact Waterdrop by Phone: 1-888-352-3558 (U.S.)
2. Sample Connection
FRONT VIEW:
- A Filter Life Indicator
- B Display Screen: TDS Reading, Flushing Status, Malfunction Code
- C Activated Carbon Filter (CB)
- D Pre-sediment and Carbon Block Filter (CF)
- E Reverse Osmosis Membrane Filter (RO)
- F "POWER" Port
Diagram Description: The diagram shows the RO system connected to a faucet and drain. Labeled components include: Input Water Tubing, Power Adapter, Filtered Water Tubing, Waste Water Tubing, Drain Saddle, Faucet, and the RO System Housing.
- G "FAUCET" connector
- H "INPUT" Water Port
- I "FILTERED" Water Port
- J "WASTE" Water Port
- K Feed Water Adapter
- L Preinstalled Filtered Water Tubing With Faucet
- M Drain Saddle
- N Power Socket
- O Faucet Power Cord
3. Quick Installation
Before installation, please note:
- The RO system must be connected to the COLD water supply only.
- Do not install the system in exposure to direct sunlight or harmful chemicals, nor any place where it may be damaged.
Step 1: Install the Feed Water Adapter (K)
- Turn off cold water supply valve.
- Connect the feed water adapter to your cold water supply pipe.
Step 2: Install the RO Faucet (Non-Air Gap Faucet)
- If your kitchen sink or countertop does not have an existing hole, you will have to drill one (1") referring to the Instruction Manual.
- Insert the faucet head into faucet body.
- Insert faucet stem and power cord into the hole on countertop.
- Under the sink, slip on other parts in the order as shown in the picture.
Step 3: Install the Drain Saddle (M)
- Choose a spot on the vertical drain pipe as high as possible and drill a 1/4" hole.
- Use the "WASTE" water tubing as a guide to position the drain saddle by tightening screws and nuts evenly.
Step 4: Position the RO System Housing
- An ample flat area is required to place the system housing. Position the front panel facing towards you for future indicator checking.
Step 5: Connect the Tubings
NOTE: Make sure each tubing is inserted firmly and fully until it reach the mark on the end of the tubing.
- Connect the "INPUT" water tubing from feed water adapter (K) to "INPUT" water port (H).
- Connect the "FILTERED" water tubing from RO faucet (L) to "FILTERED" water port (I).
- Connect the "WASTE" water tubing from drain saddle (M) to "WASTE" water port (J).
Step 6: Connect Power Cord
- Insert faucet power cord into "Faucet" connector (O-G).
- Connect Power Adapter to power port (F).
Step 7: Install the Filters
- Insert the filter into its corresponding hole.
- Rotate the filter clockwise 1/4 turn. You may hear a clicking sound when the filter is fitted into the place properly.
NOTE: Please do not connect power socket (N) now.
Step 8: Start Up the System
- Turn on cold water supply valve and feed water adapter, connect power adapter.
- Wait for 5 minutes, allowing the system to flush automatically.
- Turn on RO faucet, allow it to run 30 minutes until the display screen shows TDS reading.
4. Display Screen and Filter Life Reminder
The screen display and indicator lights will go off after 5 minutes when the system stops making water.
Section 1: Display Screen
- TDS Display: The built-in TDS sensor detects the water quality when the system begins to work, the front panel screen and RO faucet screen show above.
- Flushing Display: Every time the system flushes, the front panel screen and RO faucet screen show above.
- Malfunction Display: When the system is in fault, the front panel screen and RO faucet screen show E02, E03 and E04. Please see the Instruction Manual for detailed solutions.
Section 2: Filter Life Reminder
Indicator on System Housing:
- Good
- Replace Soon
- Replace Now
Indicator on RO Faucet:
- Good
- Replace Soon
- Replace Now
- Flushing (on RO Faucet)
- Malfunction (on RO Faucet)
There are filter life indicators on system housing and RO faucet that notify you to perform routine filter replacement by color change.
Faucet | Remaining Life (Day) | Remaining Capacity (G) | Status |
---|---|---|---|
White | >15 | >40 | Good |
Yellow | <15 | ≤40 | Replace Soon |
Red | ≤0 | ≤0 | Replace Now |
White flash (on RO Faucet) | / | / | Flushing |
Red Error (on RO Faucet) | / | / | Malfunction |
NOTE: The indicators notify in accordance with usage time or processing capacity of the filters, whichever comes first.