EZ-PD™ Protocol Analyzer CY4500-EPR
Quick Start Guide
Kit Contents
- CY4500-Extended power range (EPR)
- USB 2.0 Type-A to Micro-B cable
- Six jumper wires (five inches each)
- Quick start guide (this document)
Before You Start
Ensure that you have the following:
- A PC with at least one Type-A port
- A USB-PD source device
- A USB-PD sink device
Step 1: Connect the CY4500-EPR Kit
Connect the CY4500-EPR kit to the PC using the USB 2.0 Type-A to Micro-B cable. Observe that the LED1 blinks white continuously.
Image shows the CY4500-EPR device connected to a PC via a USB cable, with the LED indicator highlighted.
Step 2: Driver Installation and Enumeration
Wait for the installation of the driver for the protocol analyzer to complete. The board enumerates as Infineon EZ-PD™ Analyzer under Universal Serial Bus devices in Windows Device Manager.
Screenshot of Windows Device Manager showing the 'Infineon EZ-PD™ Analyzer' listed under 'Universal Serial Bus devices'.
Step 3: Launch EZ-PD™ Protocol Analyzer Utility
- Download and install the EZ-PD™ Protocol Analyzer Utility from the Infineon website.
- Start the EZ-PD™ Protocol Analyzer Utility.
- On the utility, click the start icon.
- Select Action > Start to capture the data.
- Once the capture starts, the LED1 on the CY4500-EPR turns green.
Screenshot of the EZ-PD™ Protocol Analyzer Utility interface, showing data capture in progress.
Step 4: Connect USB-PD Source and Sink
Connect the host and sink device to CY4500-EPR:
- Connect the Type-C plug/receptacle of the CY4500-EPR EZ-PD™ Protocol Analyzer to the host/sink device.
- Connect the other end of the Type-C plug/receptacle of the CY4500-EPR EZ-PD™ Protocol Analyzer to a power adapter or any other device (not provided with the analyzer). For more information, go to CY4500-EPR EZ-PD™ Protocol Analyzer.
Image shows the CY4500-EPR device connected to a USB-PD source and sink device via USB Type-C connections.
Step 5: Capture and Analyze Packets
Observe that the utility captures the USB Power Delivery packets sent on CC lines and displays them on the screen. Click a message in the main panel to view the detailed description on the right panel.
Screenshot of the EZ-PD™ Protocol Analyzer Utility software, showing decoded USB Power Delivery packets displayed on the screen, with detailed information in a side panel.
Notes
- The older CY4500 EZ-PD™ Protocol Analyzer is compatible with the newer application (even if the application prompts to download new firmware on the device, VBUS will be limited to SPR).
- Ensure that the Type-C host and the power adapter/device is connected to the CY4500-EPR board and does not exceed 5 V on CC lines.
Device Views
CY4500-EPR (Top View)
A top view of the CY4500-EPR circuit board. Key connectors are labeled: USB Micro-B connector (J7) and USB Type-C receptacle (J2). The PSoC™ LP silicon chip is also visible.
CY4500-EPR (Side View)
A side view of the CY4500-EPR device, indicating the location of the USB Type-C signals and message trigger header pins (J1, J8).
CY4500-EPR (Bottom View)
A bottom view of the CY4500-EPR circuit board, with pin labels clearly marked: CC1, CC2, SBU1, SBU2, VBUS, GND, SOM, EOM, MTR.
Contact and Further Information
Contact technical support to obtain the kit document and software examples. For additional details, see the kit guide available on the Infineon kit webpage: https://www.infineon.com/CY4500-EPR
Document number: 002-39541 Rev. **
Date: 05/2024