1. Packing List
The following items are included with your JBC CLUP Senior Tip Cleaner:
- Senior Tip Cleaner with Non-Metal Brushes (1 unit)
- Non-Metal Brushes HMP for CLU & CLR (2 units, Ref. CLMU-P2 - brushes already installed inside the cleaner)
- AC Adapter (1 unit, Part No. 0022529)
- Manual (1 unit, Part No. 0027496)
Images show the Senior Tip Cleaner unit, two sets of Non-Metal Brushes HMP, an AC Adapter with interchangeable EU and US plugs, and the Instruction Manual.
2. Features and Connections
The CLUP Senior Tip Cleaner is designed for efficient tip cleaning and offers several key features:
- Splashguard: Protects the user from splashes.
- Window: The opening where the soldering iron tip is inserted for cleaning.
- Locking tab: Used to open the splashguard.
- Power cord socket: Connection point for the AC adapter.
- ESD safe connector: Ensures electrostatic discharge safety.
- USB-B connector: For software updates and connection to JBC Manager.
- Switch panel: Contains buttons for controlling the device.
- Sensors window: Detects the presence of the soldering iron tip.
- Feet for vertical access: Allows the unit to be placed upright.
Diagrams illustrate the location of the splashguard, window, locking tab, power cord socket, ESD safe connector, USB-B connector, switch panel, sensors window, and feet for vertical access on the CLUP unit.
3. Operation
The CLUP offers different operating modes:
- Continuous mode: For constant brush rotation.
- On / Off: Powers the device on or off.
- Sensor mode: Activates brushes automatically when a tip is detected.
LED Status Indicators:
- White: Off
- Blue: Standby
- Green: Brushes activated
- Blinking Red: Brushes jammed
For optimal cleaning results, it is recommended to place the soldering iron tip between the two brushes for approximately 1 second. Longer exposure may lead to dewetting of the tip surface, causing oxidation.
If excessive pressure is applied to the brushes with the tool, the cleaner will automatically stop to protect the motors. Removing the tool from the sensor detection area will reactivate the cleaner.
The CLUP automatically switches off if the splashguard is opened during operation.
A diagram shows a soldering iron tip being inserted into the CLUP cleaner between the rotating brushes.
4. Brush Replacement
Replacing the brushes is a simple process:
- Pull the locking tab to open the splashguard.
- To remove used brushes, pull them out of the cleaner by pressing their two opposite buttons.
- To insert new brushes, simply push them into place without pressing the buttons.
Illustrations demonstrate pulling the locking tab to open the splashguard and how to press buttons to remove used brushes, and insert new ones.
5. Collection Tray
The solder collection tray can be removed for disposal of solder waste. The tray can be removed without needing to disassemble the brushes.
An illustration shows the CLUP cleaner with the solder collection tray being removed from the bottom.
6. Brush Range
JBC offers a variety of brushes for the CLU & CLR models, categorized by material and core color:
Metal Brushes
Ref. | Type | Cleaning | Max. time use | Recommended time use | Life cycle* | Core** |
---|---|---|---|---|---|---|
CLMU-A8 | Metal | Intensive | 10 s | 1-2 s | Long | Black |
CLMU-A7 | Metal | Intensive | 10 s | 1-2 s | Long | Blue |
Non-Metal Brushes
Ref. | Type | Cleaning | Max. time use | Recommended time use | Life cycle* | Core** |
---|---|---|---|---|---|---|
CLMU-P1 | Non-metal | Gentle | 5 s | 1-2 s | Extended | Black |
CLMU-P7 | Non-metal | Gentle | 5 s | 1-2 s | Extended | Blue |
CLMU-P2 | Non-metal HMP | Gentle | 5 s | 1-2 s | Extended | Black |
CLMU-P8 | Non-metal HMP | Gentle | 5 s | 1-2 s | Extended | Blue |
⚠Important: Only use the non-metal Brushes when they are turning. Incorrect use will damage them.
* When used properly, non-metal brushes have a longer life than metal ones.
** The blue core distinguishes brushes for lead-free and leaded soldering.
Images display various brush types: Metal Brushes (Black/Blue core), Non-Metal Brushes (Black/Blue core), and Non-Metal Brushes HMP (Black/Blue core), each with their reference numbers.
7. Maintenance
Before performing any maintenance or storage, always unplug the equipment from the mains.
- Use a damp cloth to clean the splashguard and the inside of the unit.
- Periodically check that the sensors window is clean. Use a cotton bud with alcohol for cleaning.
- Keep the brushes and the solder collection tray clean.
- Replace any defective or damaged parts using original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
A close-up of the JBC CLUP Senior Tip Cleaner with an arrow pointing to the 'Sensor Window'.
8. USB Connector
Download the latest software from the JBC website to improve your CLUP's functionality.
JBC Updater
Update the cleaner software via USB connection:
Visit: www.jbctools.com/software.html
Diagram shows a USB AB Cable connecting a laptop running JBC Updater software to the CLUP cleaner.
JBC Manager
Manage and monitor multiple JBC stations from your PC using the JBC Manager. You can also export data to another PC.
Visit: www.jbctools.com/manager.html
Features of JBC Manager:
- Manager Settings: Change settings for a group of JBC stations simultaneously.
- Register Settings: Create real-time graphs of the soldering process, including power and temperature data.
Diagram shows multiple JBC stations connected via a USB Hub to a laptop running JBC Manager software.
9. Safety
⚠It is imperative to follow safety guidelines to prevent electric shock, injury, fire, or explosion.
- Do not use the appliance for any purpose other than tip cleaning; it is not a tool stand.
- The AC Adapter power supply must be plugged into approved bases.
- Do not leave the appliance unattended while it is running.
- When removing the power cord, hold the plug, not the wire.
- Avoid contact with moving parts.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves to avoid harm.
- This appliance can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning safe use and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
- Utmost care must be taken with liquid tin waste, which can cause burns.
- Be careful with fumes produced during soldering.
10. Specifications
AC Adapter: | Input: 100-240 V, 5/60 Hz Output: DC 24 V, 2 A |
Brush diameter: | 50 mm |
Weight: | 2.1 kg (4.63 lb) |
Dimensions: | 128 x 131 x 137 mm |
Ambient Operating Temp: | 10 to 40 °C / 50 TO 104 °F |
The unit complies with CE standards.
Features ESD protected housing with “skin effect” protection.
Warranty
JBC offers a 2-year warranty covering manufacturing defects, including replacement of defective parts and labor.
The warranty does not cover product wear or misuse.
To validate the warranty, the equipment must be returned, postage paid, to the dealer where it was purchased.
Get an extra 1-year JBC warranty by registering at: https://www.jbctools.com/productregistration within 30 days of purchase.
End-of-Life Disposal
This product should not be disposed of in general waste. In accordance with European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.