Fixture Diagram
The fixture diagram illustrates the assembly components. Key parts labeled are: [A] Mounting Strap, [B] Outlet Box, [C] Mounting Screws, [D] Canopy, [E] Strap Mounting Screws, and [F] Lockup Knobs. Wires are shown connecting from the outlet box to the fixture.
Parts List
- [A] Mounting Strap
- [B] Outlet Box
- [C] Mounting Screws
- [D] Canopy
- [E] Strap Mounting Screws
- [F] Lockup Knobs
Cautions
- CAUTION – RISK OF SHOCK: Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
- WARNING: This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.
Installation Instructions
- Find the appropriate threaded holes on mounting strap[A] that align with hole distance in canopy[D]. Thread mounting screws[C] into threaded holes starting from outlet box[B] side.
- Attach mounting strap[A] to outlet box[B] using the strap mounting screws[E]. The mounting strap can be adjusted to suit the position of the fixture.
- Grounding instructions:
- a) On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap the ground wire from the outlet box around the green ground screw, and thread it into the hole.
- b) On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread it into the mounting strap.
Diagram Description (Grounding Method a): Outlet box ground wire wraps around the green ground screw on a mounting strap with dimples.
Diagram Description (Grounding Method b): Outlet box ground wire is placed under a cupped washer and green ground screw on the mounting strap.
Diagram Description (Wire Connector): Illustrates a wire connector joining electrical wires.
- Make wire connections. Reference the chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to: Connect White Supply Wire to: Black White *Parallel cord (round & smooth) *Parallel cord (square & ridged) Clear, Brown, Gold or Black without Tracer Clear, Brown, Gold or Black with Tracer Insulated wire (other than green) with copper conductor Insulated wire (other than green) with silver conductor Note: When parallel wire (SPT 1 & SPT 2) is used, the neutral wire is square shaped or ridged, and the other wire will be round in shape or smooth. (See illustration).
Diagram Description (Neutral Wire Identification): Illustrates parallel wires, showing one wire as square-shaped or ridged (neutral) and the other as round or smooth.
- Push the fixture to the wall, carefully aligning the mounting screws with the holes in the canopy. Ensure all wires are inside the canopy and do not get pinched between the canopy and the wall.
- Thread lockup knobs[F] onto the mounting screws and tighten to secure the fixture to the wall.
- Insert recommended bulbs (not supplied).
Cleaning
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
For warranty information please visit: kichler.com/warranty