Key Functions
- ON/OFF
- Turns the light on or off. If the lamp is turned off before it's short-circuited, it will remain off after power-on again.
- Auto Mode
- Pressing the "Auto Mode" button activates the sensor, and all settings remain as they were before the light was switched on/off.
- Reset
-
- Pressing the "Reset" button sets the brightness to the maximum level.
- Pressing the "Reset" button with DIP switches will control the product via DIP switches. If not, all settings revert to initial values: 100% detection range, 5s hold time, no standby time, and disabled daylight threshold.
- +/- Buttons
-
- Adjusts brightness from 10-100% in on/off mode.
- Adjusts the highest brightness from 60-100% in sensor mode.
- Start
- Pressing "Start" allows users to customize scenes, including detection range, daylight threshold, hold time, standby dimming level, and standby period.
- Memory
-
- Pressing "Memory" saves all current settings.
- Settings are retained from the last use if not reset.
- Apply
-
- Pressing "Apply" delivers the saved setting.
- Pressing "Apply" without "Memory" will make all settings a one-time operation.
- Settings must be completed within 30 seconds, otherwise, the device exits memory mode.
Setting Parameters
The remote allows for adjustment of various parameters:
- Detection Area: Press to define detection area (100%/75%/50%/25%).
- Hold Time: Press to define hold time (5s/30s/1min/3min/5min/10min/20min/30min).
- Stand-by Dimming Level: Press to define standby dimming level (10%/20%/30%/50%).
- Stand-by Period: Press to define standby period (0s/10s/30s/1min/5min/10min/30min/+∞). Note: "0s" means no standby period; "+∞" means unlimited standby period.
- Daylight Threshold: Press to define daylight level (2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/Disable). Note: "Disable" means the light turns on with any movement, regardless of ambient light.
Test (2s): The "Test (2s)" button is for post-commissioning testing. Pressing it puts the sensor into test mode with a hold time of only 2 seconds.
HD03R Instruction
Memory & Apply Mode
- Press the "ON/OFF" button to turn the light on or off.
- To reset parameters, follow these steps:
- Press ON to turn on the light if it was off.
- Press "Start" to set the sensor correctly.
- Press the buttons for Detection range, Hold time, Stand-by dimming level, Stand-by period, and Daylight threshold sequentially.
- Press "Memory" to save the settings.
- To program other lights in an array with similar sensors:
- Press "ON" to the second sensor.
- Press "Apply".
Isolated Setting Mode
- Press the "ON/OFF" button to turn the light on or off. Press "Auto Mode" to activate settings saved previously or the factory default settings.
- To reset parameters, follow these steps:
- Press ON to turn on the light if it was off.
- Press any button among "Auto Mode", "Reset", "Test", and "Apply" to initiate the sensor detection mode.
- Press the buttons for Detection range, Hold time, Stand-by dimming level, Stand-by period, and Daylight threshold sequentially.
- Settings are saved automatically and remain active until a reset is performed.