DS (DOUBLE SPEED) SERIES AIR-BLOWER USER MANUAL
MODEL: DS-1.25HP
VEVOR is committed to providing tools at competitive prices. The terms "Save Half" and "Half Price" represent an estimate of potential savings compared to major brands and may not apply to all product categories. Customers are advised to verify savings carefully when placing an order.
NEED HELP? CONTACT US!
Have product questions or need technical support? Please feel free to contact us:
Email: CustomerService@vevor.com
This is the original instruction manual. Please read all instructions carefully before operating. VEVOR reserves the right to interpret its user manual. The appearance of the product is subject to the item received. VEVOR will not provide further notification for technology or software updates on its products.
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should always be followed:
- [Information] Warning - To reduce the risk of injury, user must read instructions manual carefully.
- [Warning] This symbol, placed before a safety comment, indicates a kind of precaution, warning, or danger. Ignoring this warning may lead to an accident. To reduce the risk of injury, fire, or electrocution, please always follow the recommendation shown below.
- [AC] Alternating current
- [Recycling Symbol] Correct Disposal of this product: This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Use Only on GFCI Protected Receptacles
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. Prevent sharp and hard objects from dropping into and prevent liquid from flowing into the air-blower. Do not wash the air-blower with liquid; you must first unplug it from the power source and then wipe it with a wet cloth when you clean it. Do not draw and pull motor leads, and do not bump the air-blower. It is best to use the air-blower between -5 and 50 degrees centigrade. If the air-blower is exposed to high temperatures, the motor leads, enameled cables, and heating bodies will age and shorten its life.
Keep Children Away: Do not allow children to play with or around the unit in any way, which could result in injury.
DANGER: Improper installation of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal.
CAUTION: Use only in a 10A power circuit or more. Use only a separate circuit. Do not operate this item in the same circuit as other electrical equipment; it must have its own circuit. Do not modify the plug provided. If it does not fit the outlet, have the proper outlet installed by a qualified electrician. The appliance must be positioned so that the plug is accessible. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person to avoid a hazard.
Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
TECHNICAL PARAMETER
MODEL | DS-1.25HP |
---|---|
AMPS | 7.8A |
VOLT. & FREQ. | 115V~/60HZ |
OPERATION
Place the air-blower on a steady surface where children can be kept away. This product is for use on a nominal 115-volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A).
Sketch (A) Description: The diagram shows a standard three-prong grounding plug with a grounding pin, connected to a power cord, which plugs into a grounded outlet box.
Use only with inflatable products. Do not use as depicted in Sketch (A) in other cases. Make sure that the product is connected to an outlet having the same configuration as the plug.
Keep Unit Grounded: This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Conveyance: During conveying the air-blower, avoid collisions and severe shaking. Please prevent sour, alkali, oil, and water from entering the air-blower; the air-blower needs protection from moisture.
Storage: Please place it in a dry and ventilated position away from sour, alkali, or corrosive gases. After using it outdoors, store it in a dry and ventilated room promptly. Do not let water enter the air-blower.
MAINTENANCE
DANGER: Unplug or disconnect the appliance from the power supply before servicing. When the air-blower has run for about half a year, it needs maintenance. You should remove dust and dirt from the inlet, impeller, and volute. The source of electrical supply must be disconnected prior to the beginning of any such servicing or cleaning operation.
Clear Motor: Please replace lubricating oil on the bearing regularly. If the bearing has worn down, you may replace it.
TROUBLESHOOTING
PROBLEM | CAUSE |
---|---|
Motor won't run |
|
Motor runs but wheel makes a scraping noise |
|
Motor is unable to run normally |
|
Printed in China
SWITCH: LOW END—, OFF—O, HIGH END—||
Manufacturer: FOSHAN SHUNDE HUAWEI AIR-BLOWER MFG CO., LTD.
Address: No.1 Jusheng Road, Hongxing, Ronggui Shunde, Foshan, Guangdong, China
MADE IN CHINA