Narwal Automatic Water Exchange Module User Manual

Narwal Automatic Water Exchange Module User's Manual

For Narwal Freo Robot Vacuum and Mop

Warnings

  • ⚠️ To avoid water leakage, please use a dedicated pipe cutter ✂️ and avoid bending the pipe.
  • ⚠️ To avoid electric shocks ⚡, please connect the water supply BEFORE connecting the electricity.
  • ✔️ Please ensure the self-test has been properly completed before using the module.

Product Components

The Automatic Water Exchange Module consists of the following main components:

  • Clean Water Tank
  • Dirty Water Tank
  • Base Station
  • Clean Water Inlet Pipe
  • Dirty Water Outlet Pipe

[Diagram description: A transparent view of the base station showing the clean and dirty water tanks, connected by inlet and outlet pipes to the base station.]

Package Contents

Main Unit

  • Automatic Water Exchange Module*1

Standard Accessories

  • Water Pipe Adapter*1
  • Clean Water T-joint*1
  • Clean Water Filter *1
  • Explosion-proof Pipe*1
  • Control Box*1
  • Clean Water Pipe*6m
  • Dirty Water Pipe*6m
  • Decorative Pipe*1
  • Wrench*1 ?
  • Cable organizer*1 ?
  • Pipe cutter*1 ?
  • Cable tie*1 ?️

[Diagram description: Illustrations of each component listed above, numbered 1 through 13.]

Installation Instructions

Installation Environment

Ensure the following conditions for optimal installation:

  • Pipeline distance between water supply and base station: ≤19.7ft.
  • Pipeline distance between dirty water outlet and base station: ≤19.7ft.
  • Height of the dirty water pipe from the ground: ≤2.6ft for smooth drainage.
  • Water supply connection: PT 1/2-14 thread is recommended. Use a compatible adapter if needed.
  • Water supply pressure: 0.14 MPa to 0.8 MPa. A booster pump or pressure relief valve may be required outside this range.
  • Avoid using pipe valves prone to rusting or leakage at the water source.

Installing the Water Pipeline

[Diagram description: An overview diagram showing the faucet ?, clean water T-joint, explosion-proof pipe, control box, solenoid valve cable, clean water pipe, and dirty water pipe connected to the base station and a water outlet ?.]

Step 1: Install Clean Water T-joint and Explosion-proof Pipe

  1. Turn off the water supply.
  2. Select the appropriate installation location based on specific conditions.
  3. Use the supplied wrench ? to remove the faucet, angle valve, or other water supply joints.
  4. Check and install the filter inside the T-joint.
  5. Install the T-joint onto the water supply joint, ensuring the filter is on the water inlet side.
  6. Use the socket wrench to tighten the explosion-proof pipe to the clean water T-joint.

[Diagram description: Detailed illustrations showing the connection of the clean water T-joint, filter, and explosion-proof pipe to a water supply faucet. Two connection options are illustrated: one connecting to the female thread end of the water supply, and another connecting to the outlet pipe of the faucet.]

Step 2: Install the Control Box

  1. Check that the filter is installed in the inlet pipe of the control box.
  2. Connect the other end of the explosion-proof pipe to the male thread end of the control box.
  3. Use the socket wrench to tighten the explosion-proof pipe clockwise.

[Diagram description: Illustration showing the control box with its filter and the connection of the explosion-proof pipe.]

Step 3: Install the Automatic Water Exchange Unit

  1. Open the top lid of the base station and remove the dirty water tank and clean water tank.
  2. Remove the pin and blowhole protection covers. [Visual cue: "Blowhole protection cover", "Pin protection cover"]
  3. Pry off the rear protection cover using your hand or a screwdriver ?.
  4. Insert a screwdriver into the inlet and outlet pipes of the base station until the inner protection cover is released. [Visual cue: "Protection cover"]
  5. Place the automatic water exchange module vertically into the base station along the rear panel.
  6. Store spare parts in the base station for future use.

[Diagram description: A sequence of illustrations showing the steps for accessing and installing the main unit into the base station, including removing covers and placing the module.]

Step 4: Install the Pipeline

  1. Firmly insert the clean water pipe into the quick connector of the control box until the marker line disappears. If the marker line is visible, the pipe is not installed properly.
  2. Determine the required length for the dirty water pipe based on the sewage outlet position. Cut off excess pipe length using the pipe cutter ?. (A pipe that is too long may affect sewage discharge.)
  3. Connect the other ends of the clean water pipe and dirty water pipe to their respective adapters. Insert the pipes until the marker line is no longer visible.
  4. Insert the water pipe adapter into the base station until it clicks. Check the O-ring condition before connecting; apply neutral cleaning liquid for lubrication if needed.
  5. Connect the solenoid valve cable of the control box to the back of the base station. Secure the dirty water pipe with a cable tie ?️ to prevent it from slipping out of the sewage outlet.
  6. Use the cable clip to organize the clean water pipe and dirty water pipe into the storage pipe, cutting off any excess. [Visual cue: "Decorative pipe"]

[Diagram description: Illustrations detailing the connection of the clean and dirty water pipes to the control box, adapters, and base station. Also shows cutting the dirty water pipe and securing it with a cable tie.]

Step 5: Installation Self-test

  1. Ensure the power supply is reliably connected and there is adequate space around the unit.
  2. On the robot's homepage, swipe down to access the drop-down setup menu.
  3. Swipe to the "Automatic Water Change Self-test" function and tap "Confirm" to start.
  4. Upon completion, the screen will display "Automatic Water Change Completed". If any abnormalities occur, follow the on-screen instructions for troubleshooting.

[Diagram description: Screenshots of the robot's interface showing the "Freo Mode", the drop-down menu, the self-test selection screen, and the completion message.]

Accessories Maintenance

Filter Maintenance

  1. Turn off the water supply. Use a socket wrench to unscrew the explosion-proof pipe.
  2. Remove the filter from the control box connector and rinse it with clean water.
  3. Reinstall the filter. Tighten the explosion-proof pipe with the socket wrench to ensure a secure connection. Open the clean water valve.

[Diagram description: Illustration showing the filter, socket wrench, and the connection point on the control box for filter maintenance.]

Duckbill Valve Maintenance

  1. Take out the drain cleaning stick located under the top lid of the automatic water exchange module.
  2. Press the button on the quick adapter to detach the water pipe adapter.
  3. Insert the drain cleaning stick into the outlet and move it in and out 3-5 times.
  4. Reinstall the quick connector and the drain cleaning stick.

[Diagram description: Illustration showing the water pipe adapter, drain outlet, and the drain cleaning stick being used for maintenance.]

Specifications

Model Dimensions Weight Color Maximum pressure of inlet water
YJMA002 335*110*260mm approx. 1.2 kg white 1.0 MPA

Error Codes and Prompts

If an error occurs with the automatic water exchange unit, consult the table below for troubleshooting.

Error Code Base Station Touchscreen Prompt Robot Voice Prompt Solution
3000 Automatic water exchange module error. Scan the code for help. Automatic water exchange module error. Scan the code for help. 1. Check if the water supply is turned off. 2. Check if the pipeline is damaged or leaking. 3. Check if the filter in the clean water tank is blocked.
3001 Automatic water exchange module error. Scan the code for help. Automatic water exchange module error. Scan the code for help. Please contact the after-sales service.
3002 Automatic water exchange module error. Scan the code for help. Automatic water exchange module error. Scan the code for help. 1. Check if the cleaning components are blocked. 2. Check if the dirty water duckbill valve is completed closed. 3. Check if the pipeline is blocked (difficult for the user to troubleshoot). 4. Check if the ventilation valve doesn't work. (Cannot be troubleshot by the user)
3003 Automatic water exchange module error. Scan the code for help. Automatic water exchange module error. Scan the code for help. Please contact the after-sales service.
3004 No waterpipe control module detected. Reinstall it properly. No waterpipe control module detected. Reinstall it properly. 1. Check if the waterpipe control module is correctly installed on the clean water pipe. 2. Check if all valves of the clean water pipe are opened and the house's water supply is enabled. 3. If the error persists, please contact the after-sales service.
3005 Water spray system error. Scan the code for help. Water spray system error. Scan the code for help. 1. Check if the clean water pipe is properly connected. 2. Check if all valves of the clean water pipe are opened and the house's water supply is enabled. 3. If the error persists, please contact the after-sales service.
3006 Automatic water exchange module error. Scan the code for help. Automatic water exchange module error. Scan the code for help. 1. Check if the cleaning components are blocked. 2. Check if the dirty water duckbill valve is completed closed. 3. Check if the pipeline is blocked (difficult for the user to troubleshoot). 4. Check if the ventilation valve doesn't work (cannot be troubleshot by the user).
3007 Pumping system error. Check the quick connector. Automatic water exchange module error. Scan the code for help. Please contact the after-sales service.
3008 Drainage system error. Check the dirty water pipe. Automatic water exchange module error. Scan the code for help. 1. Please check if the dirty water pipe is bent or pressed by a heavy object. 2. Use the drain cleaning stick to dredge the duckbill valve in the quick connector. 3. If the error persists, please contact the after-sales service.

Warranty Policy Summary

Narwal Limited Warranty

This Limited Warranty applies to Narwal products purchased in the United States and Canada. It warrants products against defects in material and workmanship under normal use for a period of one (1) year from the date of delivery (the "Warranty Period").

How to Obtain Warranty Service: Contact support@narwal.com or submit a request via Narwal.com, providing the product serial number and proof of purchase.

What Narwal Will Do: Narwal will, at its option, repair the product using new or refurbished parts, or exchange the product with a new or refurbished equivalent.

What's Not Covered: This warranty does not cover normal wear and tear (including batteries), damage from misuse, accidents, neglect, unauthorized modifications, use of non-recommended parts, or external causes beyond reasonable control. Consumable items are also excluded.

Limitation of Liability: Narwal's sole and exclusive remedy is repair or replacement. Narwal's liability is limited to the purchase value of the product, except in cases of gross negligence or intentional misconduct.

For full details, please refer to the official Narwal website.

Product Warranty Card & Maintenance Records

This section provides fields to record user information, product details, and maintenance history.

Product Warranty Card Fields:

  • User Name
  • Address
  • Phone No.
  • Product Name and Model Model
  • Serial Number
  • Purchase Date

Maintenance Records Table:

Maintenance Date Fault Description and part Replacement Maintenance Center Maintenance Engineer
[Record 1]
[Record 2]
[Record 3]

Manufacturer Information

Manufacturer: Yunjing Intelligence Innovation (Shenzhen) Co., Ltd.

Address: Room A2901, Yunzhongcheng, Building 1, Vanke Yuncheng VI, Dashi 2nd Road, Xili Community, Xili Street, Nanshan District, Shenzhen, Guangdong, China

Email: support.au@narwal.com

Website: www.narwal.com

PDF preview unavailable. Download the PDF instead.

Automatic Water Exchange System User Manual Adobe InDesign 16.1 (Windows) Adobe PDF Library 15.0

Related Documents

Preview Narwal Freo Z Ultra Robot Vacuum and Mop User Manual
Comprehensive user manual for the Narwal Freo Z Ultra Robot Vacuum and Mop, covering setup, operation, cleaning modes, maintenance, and technical specifications. Learn how to get the most out of your device.
Preview Narwal Automatic Water Exchange Module User Manual
Comprehensive user manual for the Narwal Automatic Water Exchange Module, designed for the Narwal Freo Robot Vacuum and Mop. Covers installation, product components, package contents, maintenance, specifications, error codes, and warranty information.
Preview Narwal Freo X Ultra Robot Vacuum and Mop User Manual
Comprehensive user manual for the Narwal Freo X Ultra Robot Vacuum and Mop (Model YJCC015), detailing setup, operation, maintenance, safety instructions, specifications, and warranty information.
Preview Narwal Freo X Ultra Robot Vacuum and Mop User Manual
Comprehensive user manual for the Narwal Freo X Ultra Robot Vacuum and Mop (Model YJCC015), covering setup, operation, maintenance, safety instructions, and warranty information.
Preview Narwal Freo Z Ultra Robot Vacuum and Mop User Manual
Comprehensive user manual for the Narwal Freo Z Ultra Robot Vacuum and Mop Combo (Model YJCC017). Learn about product features, setup, operation, maintenance, and specifications.
Preview Narwal Freo Z Ultra Robot Vacuum and Mop User Manual - Model YJCC017
Comprehensive user manual for the Narwal Freo Z Ultra Robot Vacuum and Mop (Model YJCC017). Learn about setup, operation, cleaning modes, maintenance, and specifications for optimal performance.
Preview Narwal YJCC032 Robot Vacuum and Mop: Instruction Manual and User Guide
Comprehensive instruction manual for the Narwal YJCC032 robot vacuum and mop. Covers setup, operation, safety, maintenance, specifications, and warranty information.
Preview Narwal YJCC019 Robot Vacuum and Mop User Manual
User manual for the Narwal YJCC019 Robot Vacuum and Mop, detailing setup, operation, features, maintenance, and troubleshooting for efficient home cleaning.