Resistex Miks LED Downlight

Installation and Safety Guide

Product Overview

This document provides installation instructions for the Resistex Miks LED downlight. The Miks downlight is designed for low luminance applications and offers adjustable orientation.

Installation Instructions

Preparation

  • Never work on the luminaire when it is live (under voltage). ⚠️
  • The installation must be performed by a qualified professional electrician in compliance with standards and regulations for electrical installations.
  • Risk of electrostatic discharges (ESD Norm). Handle with precautions.
  • Please observe the notes and steps described in the mounting instructions.

Mounting Steps

  1. Step 1: Ceiling Cutout

    Create a circular cutout in the ceiling with a diameter of Ø69 mm (+/-1 mm).

  2. Step 2: Insert Fixture

    Insert the Resistex Miks LED downlight fixture into the prepared ceiling cutout from below. An upward arrow indicates the insertion direction.

  3. Step 3: Secure Fixture

    Rotate the fixture to secure it in place within the ceiling cutout.

  4. Step 4: Wire Connection (Connector)

    Open the integrated connector on the fixture. Insert the live (L), neutral (N), and earth wires into the appropriate terminals. Ensure wires are properly stripped and inserted.

  5. Step 5: Prepare Connector Closure

    Ensure all wires are correctly seated within the connector terminals.

  6. Step 6: Close Connector

    Close the connector securely. A click indicates it is properly latched.

  7. Step 7: Terminal Block Connections

    Connect the mains power supply wires to the fixture's terminal block: Live (L), Neutral (N), and Earth. The diagram shows the terminal layout.

  8. Step 8: Final Fixture Placement

    The fixture is now installed and wired. Ensure it is flush with the ceiling.

  9. Step 9: Wiring Verification

    Verify the wiring connections. A diagram shows correct (✔️) and incorrect (❌) connection methods, likely related to wire insulation or polarity.

  10. Step 10: Final Installation View

    The Resistex Miks downlight is fully installed in the ceiling.

Safety Notes

  • Never work on the luminaire when it is live (under voltage). ⚠️
  • The installation must be performed by a professional installer in compliance with standards and regulations for electrical installations.
  • Risk of electrostatic discharges (ESD Norm). Handle with precautions.
  • Please observe the notes and steps described in the mounting instructions.

Maintenance Instructions

  • Do not use chemical or abrasive products to clean the fixture. ?
  • Keep these instructions for dismantling or future maintenance.
  • Additional information about RESISTEX luminaires is available on the website www.resistex-sa.com.
  • RESISTEX cannot be responsible for any misuse of the product.

Certifications and Company Information

The product meets the following standards:

  • IP65: Protection against dust and water jets.
  • IK07: Protection against mechanical impacts.
  • Class II: Double or reinforced insulation.
  • RoHS Compliant: Restriction of Hazardous Substances.
  • CE Marked: Conforms to European standards.
  • Warranty: Information available.

Company: RESISTEX EXPLOITATION

Address: 11 Quai de la Banquière CS 80010, 06730 Saint-André-de-la-Roche, France

Contact: Tél. 04 93 276 276 - Fax 04 93 276 280 - contact@resistex-sa.com

Website: www.resistex-sa.com

APE 2740Z - Siret 487 593 477 00010 - SAS CAPITAL 649979 € - T.V.A. F.R. 73 487 593 477

Models: Miks 1283lm 4000K Ceiling Light, Miks, 1283lm 4000K Ceiling Light, 4000K Ceiling Light, Ceiling Light, Light

File Info : application/pdf, 2 Pages, 676.99KB

PDF preview unavailable. Download the PDF instead.

963266 NOT1

References

GPL Ghostscript 9.53.3

Related Documents

Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation, safety, and maintenance instructions for the Resistex Miks LED downlight, featuring adjustable and low luminance options. Includes wiring diagrams and company details.
Preview Resistex MIKS 1027lm CCT B.LUM Recessed Downlight - Technical Specifications
Detailed technical specifications for the Resistex MIKS 1027lm CCT B.LUM recessed downlight, including its features, dimensions, performance metrics, and compliance information.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation instructions for the Resistex Miks LED downlight, covering safety, maintenance, and step-by-step mounting procedures. Includes technical specifications and company information.
Preview Resistex Miks LED Downlight Installation Guide and Safety Instructions
Comprehensive installation guide for the Resistex Miks LED downlight, covering safety notes, maintenance, and step-by-step assembly instructions. Features adjustable and low-luminance options.
Preview Resistex Miks Recessed LED Downlight Installation Guide
Official installation instructions for the Resistex Miks recessed LED downlight. Learn how to safely and correctly install your Miks fixture, including safety precautions, maintenance tips, and step-by-step mounting guidance.
Preview Resistex Miks LED Downlight Installation Guide
Comprehensive installation instructions for the Resistex Miks LED downlight, detailing safety precautions, wiring, and mounting steps for professional installation.
Preview Resistex Miks LED Downlight Installation and Safety Guide
Comprehensive installation instructions and safety guidelines for the Resistex Miks LED downlight, detailing mounting, electrical connections, and maintenance. Includes technical specifications and certifications.
Preview Resistex 963266 MIKS Lighting Fixture - EU Declaration of Conformity
Official EU Declaration of Conformity for the Resistex 963266 MIKS lighting fixture, detailing compliance with relevant European directives and standards for safety, EMC, RoHS, and eco-design.