VEVOR Macerator Pump User Manual

Model: FLO500-BE

Technical Support and E-Warranty Certificate: www.vevor.com/support

VEVOR is committed to providing tools at competitive prices. Phrases like "Save Half" or "Half Price" represent an estimated saving compared to major brands and do not guarantee savings across all product categories. Customers are advised to verify savings when placing an order.

Product Overview

The FLO500-BE is a macerator pump designed for indoor use, specifically for wall-row toilets with horizontal drain holes. It is intended for family use only and should not be used for business or industrial purposes. The pump automatically starts when sewage reaches a certain level.

Normal Application Area: Treatment of human wastage, toilet paper, and water.

Not Suitable For: Hygiene covers, cotton plugs, sanitary towels, cotton bars, other hygiene products, or any hard objects.

Specially Connects With:

FLO500-BE Specifications

ModelInputMax PowerMax FlowMax LiftWater InletWater Outlet
FLO500-BE (US)AC110-120V 60Hz0.7 HP29 GPM26 ftWC+31
FLO500-BE (EU)AC220-240V 50Hz500 W110 LPM8 mWC+31

WARNING: Only installations conforming to the above specifications are acceptable.

2. Installation

Diagram Description: A schematic showing the macerator pump connected to a toilet, sink, and shower. The pump is positioned below the toilet. Pipes from the toilet, sink, and shower lead to the pump's inlet. An outlet pipe from the pump ascends and then runs horizontally to a main drain. Indicators show the pump is below the toilet, with a minimum 15cm clearance noted. Pipe inclination indicators suggest a recommended slope.
Diagram Description: An illustration of the macerator pump unit with numbered parts: 1. Vent hole (carbon filter), 2. Inlet sanitary fixture, 3. Outlet discharge pipe, 4. Inlet toilet, 5. Inlet sanitary fixture, 6. Emergency outlet, 7. Inlet sanitary fixture, 8. Emergency outlet.

Follow installation and maintenance instructions in this manual for normal operation. Incorrect installation or maintenance may affect performance and safety.

3. Accessory List

The following accessories are included:

4. Connect Water Drainage Pipeline

Install the rubber ring (D) to connect the toilet to the water pump unit. Use clamps (G) (90-110mm) to secure the connection.

Install the check valve elbow (A-B) at the water drain hole and secure it with hoop (E) (32-50mm). The elbow allows for directional changes to meet installation requirements.

The elbow can connect to PVC hard pipelines or metal pipes with diameters of 22mm, 32mm, or 40mm. Avoid using flexible or soft pipes, as they may deform over time and cause leaks. Do not use water drainage pipelines exceeding 40mm in diameter, as this can impede drainage and affect the product's working life.

Important: Please ensure water drains upward for optimal performance, followed by horizontal drainage. If horizontal drainage is necessary, its length must not exceed 30cm.

Diagram Description: An illustration showing the correct outlet pipe connection. The pipe ascends, then runs horizontally with a note "Less than 12" or 30cm". It depicts correct (checkmark) and incorrect (cross) elbow configurations for the horizontal run, recommending a 135° elbow over a 90° elbow.

Ensure a 2%-3% incline for the water drainage pipe leading to the main pipeline to prevent sewage backflow. Use a 135° elbow, not a 90° elbow, for the PVC water pipe to maintain optimal range.

Ball Valve Recommendation

It is recommended to install a ball valve (not provided) near the water outlet position. This facilitates preventing sewage leakage during pump disassembly.

5. Second Method of Installing Water Drainage Check Valve

If the sewage pump is installed behind a wall, the toilet's water tank may not shield the drain hole. In this case, elbow (A-B) may not be necessary. Disassemble the black check valve from accessories (A-B) and install it into a soft pipe (C), as shown in the diagram.

Diagram Description: A diagram illustrating the second method of check valve installation, showing the check valve fitted directly into a soft pipe (C) connected to the pump's outlet.

6. Installation of Connect Pipe in Shower Room

For installation in a shower room, consider installing a wood rack, an iron shower base, or building a cement platform. This elevates the shower room floor, ensuring a 3% incline for the drainage pipe between the shower room and the sewage pump, allowing smooth sewage flow.

Diagram Description: A schematic showing the installation in a shower room. It depicts a raised shower base or platform with the macerator pump located beneath it. Pipes from the shower drain connect to the pump. A minimum 15cm height for the shower chassis is indicated, relative to the pump.

Attention: Ensure the shower room chassis is lifted by at least 15cm, considering the distance to the water pump.

6-2. Connecting Other Fixtures: If not connecting a toilet, use cover (J) to block the toilet inlet hole. Secure with hoop (G). Then, connect only the water groove, shower room, and washing machine.

7. Activated Carbon Deodorization Device

The product includes an activated carbon package for deodorization. The entire package or carbon powder can be used. It is advised to renew the activated carbon annually.

Image Description: A close-up view of activated carbon being placed into the deodorization compartment on top of the macerator pump.

8. Connection to Electrical Supply

All wiring must comply with applicable electrical codes in your territory. The macerating system requires a single-phase 110-120 volt supply.

When installed in a bathroom, the receptacle should be located 40 inches (1 meter) away (in a straight line) from a shower or bathtub. Connect only to a receptacle protected by a Ground Fault Circuit Interrupter (GFCI).

Warning: Risk of electric shock. This pump is supplied with a grounding conductor and a grounding-type attachment plug. Ensure it is connected only to a properly grounded receptacle.

9. Cautionary Notes

9-1. Application Scope: The normal application for FLOLUXURY macerating units is the disposal of human waste, toilet paper, and water. The FLOLUXURY-500 is designed for family use only and cannot handle sanitary items like condoms, tampons, sanitary pads, or cotton swabs.

9-2. Prohibited Discharges: Do not discharge acids, alkaloids, solvents, painting materials, paint strippers, food waste, plastic bags, metal objects (nails, hairpins), wood, building materials, kitty litter, or any items that could clog, damage, or corrode the unit. Disregarding these warnings may damage the unit.

Do not hang bleach blocks or hydrochloride cleaners in the toilet tank, as these can deteriorate plastic and neoprene components, potentially causing leaks.

Power Loss: During a power outage, do not use the toilet or any connected sanitary fixtures, as the unit will not function until power is restored.

Maintenance: The toilet operates like a conventional flushing toilet and requires no regular maintenance. However, cleaning the macerating unit once a year is recommended. Avoid using bleach, and be careful not to let water enter the electrical cord opening.

Operation: The macerating unit automatically starts when the toilet is flushed or when other connected fixtures (bath, shower, hand basin) discharge. It stops automatically once the contents have been pumped away.

Long Periods of Non-Use: For extended periods of non-use (vacation, power failure, maintenance), turn off the water supply to the tank and flush the unit to empty it. Ensure no leakage into the bowl from the tank.

Winterization: In areas prone to freezing, the entire system must be properly winterized. This includes draining all pipes, the toilet tank, and the macerating tank. To winterize, pour a jug of plumber's anti-freeze into the tank and flush the toilet. This activates the unit and replaces remaining water with anti-freeze. VEVOR is not liable for breakdowns due to freezing.

Ensure no faucets are left open. Dripping water can fill the pump, leading to repeated start-stops that may overheat the motor and cause a flood.

10. Disassembly for Minor Intervention

Before removing the unit, ensure the following steps are completed:

The FloLuxury-500 features an emergency drain hole for maintenance. This allows for complete drainage of sewage from the pump, facilitating disassembly. This design ensures the toilet room remains functional during pump maintenance.

Diagram Description: A close-up view of the macerator pump highlighting the "Emergency drain hole" located on its side.

FCC Information

[FCC logo] CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment!

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This product may cause harmful interference.
  2. This product must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the product.

Note: This product has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This product generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this product causes harmful interference to radio or television reception (which can be determined by turning the product off and on), the user is encouraged to try to correct the interference by one or more of the following measures:

Correct Disposal

[recycling symbol] This product is subject to European Directive 2012/19/EU. The symbol of a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste but must be taken to a collection point for recycling electrical and electronic devices.

PDF preview unavailable. Download the PDF instead.

(美、欧规)SKU1-2浸渍泵说明书-源燊-20241111 1732010591161 iLovePDF Adobe Illustrator 26.0 (Windows)

Related Documents

PreviewVEVOR FLO500 Sewage Pump Installation Instructions
Installation instructions for the VEVOR FLO500 Sewage Pump, including specifications, accessories, functions, installation guidelines, and troubleshooting.
PreviewVEVOR FLO500-DE Pro Macerator Pump User Manual & Technical Guide
Comprehensive user manual for the VEVOR FLO500-DE Pro Macerator Pump, covering specifications, installation, operation, troubleshooting, and safety guidelines. Visit www.vevor.com/support for technical assistance.
PreviewVEVOR FLO500 Sewage Pump Installation Instructions
Comprehensive installation guide for the VEVOR FLO500 Sewage Pump, detailing setup, specifications, functions, warnings, and troubleshooting for effective wastewater management.
PreviewVEVOR FLO900 Macerator Pump User Manual and Installation Guide
Comprehensive user manual for the VEVOR FLO900 Macerator Pump, detailing installation, specifications, troubleshooting, and safety guidelines for indoor use.
PreviewVEVOR Household Macerating Pump FL0700-C-M Installation Instructions
Comprehensive installation guide for the VEVOR Household Macerating Pump, Model FL0700-C-M. Learn how to properly install, connect, and maintain this powerful and reliable sewage pump for toilets, showers, sinks, and washing machines.
PreviewVEVOR FLO700 Sewage Pump Installation Instructions
This guide provides essential installation instructions for the VEVOR FLO700 Sewage Pump. Learn about its specifications, features, and proper setup for residential wastewater management. Includes troubleshooting and support details.
PreviewVEVOR RV Macerator Pump Operating Instructions
Comprehensive operating instructions for the VEVOR RV Macerator Pump, Model NMMP12-G120-12-1. Includes features, specifications, product list, wiring diagram, detailed composition, operating instructions, electrical instructions, and troubleshooting.
PreviewVEVOR FLO700 Sewage Pump Installation Instructions and Guide
Comprehensive installation instructions, specifications, warnings, and troubleshooting for the VEVOR FLO700 Sewage Pump. Learn how to properly install and maintain your macerator pump for optimal performance.