IMPORTANT
The air conditioner unit must always be stored and transported upright to prevent irreparable damage to the compressor. Allow at least 24 hours before operating after storage or transport.
SAFETY INFORMATION
- Read and keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use near water.
- Clean only with a damp cloth.
- Do not block ventilation openings. Install according to manufacturer instructions.
- Do not install near heat sources (radiators, stoves, etc.).
- Do not defeat the safety purpose of polarized or grounding-type plugs. Consult an electrician if the plug does not fit your outlet.
- Protect the power cord from being walked on or pinched.
- Do not attempt to modify or extend the power cord.
- Unplug during lightning storms or long periods of non-use.
- Ensure AC power matches voltage requirements.
- Do not handle the plug with wet hands.
- Unplug by holding the plug, never by pulling the cord.
- Do not turn the machine on/off by plugging/unplugging the cord.
- Turn off the machine before unplugging.
- Refer all servicing to qualified personnel.
- Do not expose to rain, moisture, dripping, or splashing. Do not place liquid-filled objects on top.
- Batteries should not be exposed to excessive heat.
CAUTION: Danger of explosion if batteries are incorrectly replaced. Replace only with the same or equivalent type.
Additional Precautions
- Intended for household use only.
- Use indoors in a dry location only.
- Do not place heavy objects on the machine.
- Wipe with a soft cloth; do not use wax, thinner, or irritating detergents.
- Do not allow children or pets to drink discharged water.
- Do not disassemble or attempt to repair yourself.
- Do not plug into an outlet with several other high electrical usage appliances.
- Keep away from heat sources and direct sunlight.
- If the machine makes loud noise, produces odor, or smoke, switch off, disconnect, and determine the cause.
- Do not place heavy objects on the power cord.
- Do not insert fingers or hard objects into air guide bars.
- If water is inside, turn off, unplug, and contact service personnel.
- Turn off and unplug before cleaning, moving, or servicing.
- Adult supervision is required for children or individuals with special needs.
- Place on a flat, upright surface for compressor operation.
- Do not use near gasoline or other flammable liquids.
- Do not use aerosol sprays or solvents nearby.
- Avoid restarting within three minutes of turning off to prevent compressor damage.
ELECTRICAL SAFETY
Integrated circuit breaker: The power cord features an integrated circuit breaker. Test and reset using buttons on the plug case. If the TEST button does not trip the breaker, or the RESET button does not stay engaged, unplug immediately and contact Insignia service.
Consult a qualified electrician if grounding instructions are unclear or if the outlet is not properly grounded.
This air conditioner requires a grounded 115V, 60Hz AC outlet protected by a 15 amp time-delay fuse or circuit breaker. Installation must comply with national wiring codes.
WARNING: ELECTRIC SHOCK HAZARD. Failure to follow these instructions can result in electric shock, fire, or death.
Preferred grounding method: Ensure a proper ground exists before use.
Temporary grounding: If an adapter plug is necessary, use only a UL-listed adapter (min. 120V ~ 60Hz, 13A, 1560W). Align the large slot of the adapter with the large slot in the outlet. Hold the adapter while plugging/unplugging to prevent damage to its ground terminal. Note: Attaching to a cover screw does not guarantee grounding unless the house wiring is properly grounded.
PACKAGE CONTENTS
- Portable Air Conditioner
- Remote control with batteries
- Exhaust nozzle
- Assembly hardware
- Drain hose
- Exhaust hose
- Hose adapter
- Sealing gaskets
- Window seal plate assembly
- Quick Setup Guide
FIND YOUR USER GUIDE ONLINE!
Visit www.insigniaproducts.com. Use the search bar for NS-AC8PWH9 or NS-AC8PWH9-C, then select Support & Downloads to find the User Guide in your desired language.
FEATURES
- 4,500 BTU DOE / 8,000 BTU ASHRAE rated cooling capacity
- 3-in-1 design: air conditioner, dehumidifier, and fan
- Auto On/Off timer
- Programmable timer and remote control
- Digital controls with LED display
- Multiple fan speeds with auto-control
PRODUCT OVERVIEW
Front View
The front of the unit features integrated handles at the top, a control panel with a digital LED display, mode and speed selection buttons, and adjustable louvers for directing airflow. Swiveling casters are located at the base for mobility.
Back View
The back of the unit shows the exhaust outlet for the hose, a removable filter and filter case, a drain plug, and the power cord.
REMOTE CONTROL
The remote control allows operation from a distance. It includes buttons for:
Item | Function |
---|---|
[Speed Button] | Press to raise or lower the fan speed. |
[Timer Button] | Press to set the air conditioner to turn on or off automatically. |
[Up Arrow Button] / [Down Arrow Button] | In cool mode, press to raise (▲) or lower (▼) the temperature setting. In timing mode, press to turn the timer on (▲) or off (▼). |
[Cool Mode Button] | Press to set the air conditioner to Cooling mode. |
[Dry Mode Button] | Press to set the air conditioner to Dry mode (runs both the fan and dehumidifier). |
[Fan Mode Button] | Press to turn on the fan only (no cooling). |
[Celsius/Fahrenheit Button] | Press to switch between Celsius and Fahrenheit. |
[Power Button] | Press to turn the air conditioner on or off. |
Battery Installation: Insert two AAA batteries (provided) into the remote control, ensuring correct polarity (+ and -).
SETTING UP YOUR PORTABLE AIR CONDITIONER
Before using
- Remove and store (optional) packing materials.
- Remove any shipping tape.
- Clean tape residue with liquid dish soap and a damp cloth. Avoid sharp tools, alcohol, thinners, or abrasive cleaners.
Placing your air conditioner
Place the unit on a flat, dry area near a window for venting. Maintain at least 20 inches (50 cm) of space around the unit for good air circulation and performance.
INSTALLING YOUR AIR CONDITIONER
- Screw the exhaust hose to the exhaust outlet on the back of the unit, then screw the hose adapter to the other end of the hose.
- Measure the window size.
- Install the window sealing plate in the window opening, adjusting its length to fit and locking it. This kit works with sliding windows.
- Insert the hose adapter into the vent panel and slide until it clicks into place.
- Optional: Install the security bracket with the type B screw.
- Optional: Apply the sealing gaskets to the edges of the window opening where the sealing plate is mounted to prevent warm air entry.
Note: For optimum performance, ensure the venting hose is not twisted or kinked. Shorten the hose if necessary by squeezing its sections together.
Caution: The exhaust duct is designed specifically for this air conditioner. Replacing or lengthening it could damage the unit.
Running in DRY mode: For continuous water drainage without manual tank emptying, refer to the online User Guide.
TURNING YOUR AIR CONDITIONER ON AND SELECTING THE MODE
- Press the [Power Button] to turn the unit on.
- Press the [Mode Button] repeatedly to select:
- Cool mode: Cools the room.
- Dry mode: Removes humidity (fan and dehumidifier run). Does not cool the room.
- Fan mode: Circulates air without cooling.
- In Cool or Fan mode, press the [Speed Button] to adjust fan speed. (Note: Fan speed cannot be changed in Dry mode).
Switching between Celsius and Fahrenheit: Press the [Celsius/Fahrenheit Button] on the remote control.
Setting a timer: Set the air conditioner to turn off or on after a delay of up to 24 hours using the [Timer Button] and [Up/Down Arrow Buttons]. The timer indicator lights up when set.
UNDERSTANDING LED DISPLAY MESSAGES
Item | Description |
---|---|
FL | The internal water tank is full and needs to be emptied. Refer to the online User Guide. |
E1 | Coil temperature sensor error. Turn off the unit and contact a qualified service technician. |
E2 | Indoor temperature sensor error. Turn off the unit and contact a qualified service technician. |
E4 | Anti-freezing protection. The unit has turned off automatically due to low coil temperature. It will reset when the temperature reaches 46.4°F (8°C). |
TROUBLESHOOTING
For detailed troubleshooting information, please refer to your online User Guide.
SPECIFICATIONS
For detailed specifications, please refer to your online User Guide.
ONE-YEAR LIMITED WARRANTY
Visit www.insigniaproducts.com for warranty details or see your online User Guide.
CONTACT INSIGNIA
For customer service, call 1-877-467-4289 (U.S. and Canada) or visit www.insigniaproducts.com.