R. STAHL 8530/1-MCB-STA101-C6-500-2 Circuit Breaker
Article Number: 293994
Product Overview
The R. STAHL 8530/1-MCB-STA101-C6-500-2 circuit breaker is part of the system technology components. It offers high current limitation in case of short circuits and a high breaking capacity of 10, 15, or 25 kA, resulting in reduced load on electrical lines and high selectivity with upstream fuses. The modular design allows for 1 to 4 pole configurations and nominal currents from 0.5–63 A. The maximum mounting width is 4.5 division units.
Key features include:
- Function as a separator according to EN 60947-2
- Energy limitation class 3
- Simple replacement or expansion of installations due to modular design
- Easy mounting via DIN rail in Ex e enclosures
- Adjustable thermal and magnetic tripping
- Ergonomic operating lever for safe connection and disconnection
- Protection against reclosing during maintenance using padlocks (Accessories)
Technical Data
Explosion Protection
- Applications (zones): 1, 2
- Applications (zones) Note: Can be used in zones 21/22 with Ex tb/tc enclosure protection
- IECEx Gas Approval: IECEX FMG 19.0029U
- IECEx Gas Explosion Protection: Ex db eb IIC Gb
- ATEX Gas Approval: FM19ATEX0191U
- ATEX Gas Explosion Protection: II 2 G Ex db eb IIC Gb
- Certifications: ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM)
- Certificate of Conformity: Certificate of Conformity (ATEX)
Electrical Data
- Rated operating voltage AC: 230 V
- Rated operating current: 6 A
- Frequency: 50/60 Hz
- Rated switching capacity: 10 kA
- Electrical service life: 2 x 10⁴
- Mechanical service life: 2 x 10⁴
- 1st Auxiliary function: Auxiliary contact 1 changeover contact + Error signal contact 1 changeover contact
- Voltage 1st Auxiliary function AC: 230 V
- Max. current 1st Auxiliary function: 2 A
- 2nd Auxiliary function: None
- Max. voltage 2nd Auxiliary function DC: --
- Tripping characteristic: C
- Number of poles: 1 pole
Environmental Conditions
- Ambient temperature: -40 °C ... 70 °C
- Ambient temperature (Fahrenheit): -40 °F ... 158 °F
- Ambient temperature Note: Divergent ambient temperatures based on valid certificates upon request
Mechanical Data
- Degree of protection (IP) (IEC 60529): IP2X
- Enclosure material: Thermoplastic
- Minimum connection cross-section: 1.5 mm²
- Maximum connection cross-section: 25 mm²
- Minimum AWG connection cross-section: 16 AWG
- Maximum AWG connection cross-section: 4 AWG
- Minimum connection cross-section 2: 1.5 mm²
- Maximum connection cross-section 2: 10 mm²
- Minimum AWG connection cross-section 2: 16 AWG
- Maximum AWG connection cross-section 2: 8 AWG
- Minimum HIKO connection cross-section: 0.5 mm²
- Maximum HIKO connection cross-section: 4 mm²
- Minimum HIKO AWG connection cross-section: 18 (unece.unit.AWG)
- Maximum HIKO AWG connection cross-section: 14 (unece.unit.AWG)
- Minimum torque: 2 N·m
- Maximum torque: 3 N·m
- Connection cross-section Note: 2 conductor connections (upper and lower chamber simultaneously): lower and upper chamber max. 16 / 10 mm² (only one cross-sectional difference between the upper and lower chamber can be connected). Permitted connection cross-section combinations are listed in the operating instructions.
- Width: 65 mm (2.56 in)
- Mounting width in inches: 2.56 in
- Length: 165 mm (6.5 in)
- Length inches: 6.5 in
- Installation depth: 138.3 mm (5.44 in)
- Installation depth inches: 5.44 in
- Weight: 1 kg (2.205 lb)
- Weight (lb): 2.205 lb
Mounting / Installation
- Torque: 2-3 N·m (17.7 ... 26.6 lbf-in)
- Torque for auxiliary contact: 0.4-0.6 Nm (3.5 ... 5.3 lbf in)
Technical Diagrams
Tripping Characteristic C: A graph illustrating the tripping characteristic 'C' for AC and DC, showing the multiple of rated current versus time to trip. It indicates the time delay for tripping based on the current level.
Measurement Diagram: A dimensional drawing of the circuit breaker, showing various measurements in millimeters and inches. It includes the overall dimensions, mounting dimensions, and details of the connection chambers.
Accessories
-
Cylinder Lock
For locking (Ø 3 shackle): Article No. 107115
-
Quadruple immobilization device
Locking/tagging scissors for individual component locking using up to 4 cylinder locks: Article No. 227232
-
Fixing Kit
A fixing set for mounting the component on the mounting plate without a top hat rail: Article No. 276618
Disclaimer