Aiphone IXGW-LC-RY20 Programming Guide
The IXGW-LC-RY20 is a relay adapter for the IXG Series IP multi-tenant system. This adapter provides a Form C dry contact closure used for door release when paired with an IXG-DM7-HID entrance station. The programmed relay output will activate when door release is activated on the paired IXG-DM7-HID entrance station. This relay will not pair with a standard IX Series door station. This document covers programming the IXGW-LC-RY20.
Registering and assigning outputs for the IXGW-LC-RY20
Open the IXG Support Tool, and open an existing system. Under View(V) change to Advanced.
1.1 - Select Advanced View
Click View(V) and click Advanced.
1.2 - Register Lift Control
Open Lift Control Settings and, click Registration.
Click the Enable check box for each IXGW-LC-RY20 that will be used. Station Name can be changed at this time.
1.3 - Assigning Relay Output
Click Pick Up Floor.
In the Filter section, select the Building Number / Building Name from the drop down. Then select the Adaptor Number / Name from the drop down.
The relay section will appear. Click the desired Relay Output Terminal check box for each IXG-DM7-HID station.
1.4 - Assign IP Address
Open Network Settings and, click IP Address.
Enter the IP Address and Subnet Mask. Then click Update.
1.5 - Associate Station
Open Connection and click Association Settings.
Select the Lift Control Adaptor from the Station Settings List and select the Lift Control Adaptor from the Station List. Then click Apply.
Repeat for remaining stations.
Note: After Associating, the stations will reboot. This could take between 3 and 5 minutes depending on the station.
1.6 - Upload Settings
Open Connection and click Upload Settings.
Select all stations by clicking their respective check box in the Select column. Click Settings.
The Status column will verify if the upload was successful.
Note: The Gateway Adaptor will restart when uploading the settings after changing the Maximum Simultaneous Calls. This may take up to 10 minutes to complete.