FSP180-AxxN3 Series 180W Adapter
Technical Datasheet
Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
Approvals include TÜV Rheinland, cULus, CE, FCC, and CCC. Tested to comply with FCC Standards for Home or Office Use.
Description
This product is an 180-watt AC to DC adapter intended for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications that have high wattage demands. This adapter operates at 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is designed for ITE applications.
Input Specifications
Input Voltage: | 90-264 VAC |
Input Frequency: | 47-63 Hz |
Input Current: | 100Vac, 240Vac / full load ≤ 1.2A |
No Load Power Consumption: | 115Vac, 230Vac ≤ 0.5W |
Touch Current: | 264Vac / 50Hz ≤ 0.25mA |
Input Performance
Power Factor: | 115Vac, 230Vac / full load ≥ 0.9. Provisions for harmonic reduction per EN 61000-3-2 must be present. |
Power Turn-on Time: | At 100Vac / full load, output voltage shall remain regulation ≤ 3 Sec |
Hold-up Time: | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10 ms |
Inrush Current: | 100Vac, 240Vac / full load: Shall be less than the rating of adapter critical component (including rectifiers, fuse, surge, and current limiting device). |
Operating Altitude: | 5000 meters above sea level |
Withstand Voltage: | Between AC input and secondary applied DC 4242V, test time 1 minute, cut-off current shall be less than 10mA |
MTBF: | 100Vac, 240Vac / full load: 300,000 hours at 25°C, standard SR332 |
Output Specifications
Total Output Power: | 180W |
Protection: |
|
Environment
Working Temp.: | 0~70°C (> 40°C de-rating) |
Storage Temp.: | -20~+80°C |
Working Humidity: | 20~80% RH non-condensing |
Storage Humidity: | 10~90% RH non-condensing |
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5, Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP180-AHAN3 | 12V | 15A | C14 | ≥88% | ≥89% | 19 Volts |
FSP180-AHBN3 | 12V | 15A | C6 | 19 Volts | ||
FSP180-AJAN3 | 19.5V | 9.23A | C14 | 29 Volts | ||
FSP180-AJBN3 | 19.5V | 9.23A | C6 | 29 Volts | ||
FSP180-AAAN3 | 24V | 7.5A | C14 | 35 Volts | ||
FSP180-AABN3 | 24V | 7.5A | C6 | 35 Volts | ||
FSP180-AWAN3 | 54V | 3.34A | C14 | 66 Volts | ||
FSP180-AWBN3 | 54V | 3.34A | C6 | 66 Volts |
Performance Curves
Input Voltage Derating Curve
This graph illustrates the adapter's output power capability across different input voltages. It shows that the adapter maintains 100% output power from 90 VAC to 264 VAC input.
Output Power Derating Curve
This graph shows how the adapter's maximum load capacity is affected by ambient temperature. The adapter operates at 100% load up to 40°C, with a gradual reduction in maximum load capacity as the temperature increases to 70°C.
EMC Performance
EN55032: | Class B conducted, Class B radiated |
FCC: | Class B conducted, Class B radiated |
VCCI: | Class B conducted, Class B radiated |
EN61000-3-2: | Meet Class D |
EN61000-3-3: | Meet regulation |
EN61000-4-2: | Air discharge: ±15 KV, contact discharge: ±8KV, meet criterion A |
EN61000-4-3: | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4: | Impulse: ±1kV applied to L, N, meet criterion A |
EN61000-4-5: | +1kV applied differential mode, ±2kV applied common mode, meet criterion A |
EN61000-4-6: | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A |
EN61000-4-8: | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11: | Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C; Voltage Interruptions: >95% reduction for 250 period, meet criterion C |
Power De-rating
100Vac or 240Vac, 0°C to 40°C: 100% load; 50°C: 85% load; 60°C: 70% load; 70°C: 55% load (Shall be less than the rating of adapter critical component, follow FSP specification (adapter)).
Mechanical Specifications
The FSP180-AxxN3 series adapters feature a low-profile design. The approximate dimensions are 177mm (Length) x 85.6mm (Width) x 40mm (Height). The units utilize a 4-pin molded connector for DC output, with cable lengths typically around 1800mm ± 50mm. The AC input connector varies by model, using either a C14 or C6 type. A steel wire cable tie, PE plated, is included.
FSP180-AxAN3 / FSP180-AHAN3: Detailed diagrams show the physical layout, including the 4-pin connector (PIN1: V+, PIN2: V+, PIN3: GND, PIN4: GND) and cable specifications (UL11352, #14 AWG for AHAN3). The connector is described as a 4-pin power molding with nickel plating.
FSP180-AxBN3: Similar mechanical specifications apply, with variations in AC input connector (C6 type). Diagrams illustrate the connector and cable details.
Connector Specifications
The DC output connector is a 4-pin molded type. For the FSP180-AHAN3, the pinout is specified as:
- PIN 1: V+ (RED)
- PIN 2: V+ (WHITE)
- PIN 3: GND (-) (BLACK)
- PIN 4: GND (-) (BLACK)
The DC output cable is typically 1800mm ± 50mm long and uses UL11352 wire. Heat-shrink tubing (H.S. TUBE) is used to insulate the connections, with red for positive and black for negative/ground.
Notes
*Volts express by order of 120-AHxN3/ABxN3/AAxN3/AFxN3/AWxN3