FSP 180W Adapter FSP180-AxxN3 Series
Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approvals
The adapter is tested to comply with FCC Standards for home or office use. It holds approvals including UL Listed, CULUS Listed, TÜV Rheinland Certified, CE, FCC, and CCC.
Description
This product is an 180-watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications requiring high wattage. It operates with an input voltage range of 90 to 264 VAC. The unit complies with CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, making it suitable for ITE applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 1.2A |
No load power consumption | 115Vac, 230Vac ≤ 0.5W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Power factor | 115Vac, 230Vac / full load ≥ 0.9 |
Harmonic reduction | Provisions for adding harmonic reduction per EN 61000-3-2 must be present. |
Output Specifications
Parameter | Description |
---|---|
Output voltage/current | See rating chart |
Total output power | 180W |
Over voltage protection | The adapter enters shut down if over voltage occurs at the output terminal due to an internal fault. The output trip voltage shall not exceed 19/29/35/66* volts. Normal state is restored by AC reset. |
Short circuit & Over current protection | When an internal fault occurs or an external fault is applied to the power supply causing an overload or short circuit at the output, the power supply shall shut down and enter auto-recovery mode. |
Over temperature protection | The power supply enters shut down when abnormal thermal rise occurs. Normal state is restored by AC reset. |
Brown-out protection | Set at 60Vac~70Vac |
Power turn-on time | At 100Vac / full load, output voltage shall remain regulation ≤ 3 seconds. |
Hold-up time | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms. |
Inrush current | 100Vac, 240Vac / full load: Shall be less than the rating of adapter critical components (including rectifiers, fuse, surge and current limiting device). |
Operating altitude | 5000 meters above sea level |
Withstand voltage | Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current shall be less than 10mA. |
MTBF | 100Vac, 240Vac / full load, 300,000 hours at 25°C, standard SR332. |
EMC Performance
Standard | Performance |
---|---|
EN55032 | Class B conducted, class B radiated |
FCC | Class B conducted, class B radiated |
VCCI | Class B conducted, class B radiated |
EN61000-3-2 | Meet class D |
EN61000-3-3 | Meet regulation |
EN61000-4-2 | Air discharge: ±15 KV, contact discharge: ±8KV, meet criterion A |
EN61000-4-3 | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4 | Impulse: ±1kV applied to L, N, meet criterion A |
EN61000-4-5 | ±1kV applied differential mode, ±2kV applied common mode, meet criterion A |
EN61000-4-6 | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11 | Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C. Voltage Interruptions: >95% reduction for 250 period, meet criterion C. |
Environment
Parameter | Value |
---|---|
Working TEMP. | 0~70°C (> 40°C de-rating) |
Storage TEMP. | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Derating Curves
Input Voltage Derating Curve: A line graph showing the relationship between input voltage (X-axis, 90-264 VAC) and output power (Y-axis, % Output Power). The graph indicates that output power is maintained at 100% within a specific voltage range and then begins to derate as the voltage moves towards the extremes.
Output Power Derating Curve: A line graph illustrating the relationship between ambient temperature (X-axis, 0-70°C) and maximum load capacity (Y-axis, % Max Load). The graph shows that the maximum load capacity decreases as the temperature increases, with derating starting around 40°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5, Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP180-AHAN3 | 12V | 15A | C14 | ≥88% | ≥89% | 19 Volts |
FSP180-AHBN3 | 12V | 15A | C6 | 29 Volts | ||
FSP180-AJAN3 | 19.5V | 9.23A | C14 | 35 Volts | ||
FSP180-AJBN3 | 19.5V | 9.23A | C6 | 66 Volts | ||
FSP180-AAAN3 | 24V | 7.5A | C14 | 19 Volts | ||
FSP180-AABN3 | 24V | 7.5A | C6 | 29 Volts | ||
FSP180-AWAN3 | 54V | 3.34A | C14 | 35 Volts | ||
FSP180-AWBN3 | 54V | 3.34A | C6 | 66 Volts |
Mechanical Specifications
Mechanical specifications for the FSP180-AxAN3 and FSP180-AxBN3 series are provided, showing overall dimensions, cable lengths (e.g., 1800±50 mm), and connector types. The diagrams detail specific measurements for the unit and its associated cables and connectors, including plug type and cable tie details.
Mechanical specifications for the FSP180-AHAN3 model are presented, including overall dimensions, cable lengths (e.g., 1500±50 mm), and the 4-pin power molding connector type. Detailed measurements for the unit, cables, and connectors are illustrated.
Connector Specifications
Connector specifications for the FSP180-AHAN3 model detail the 4-pin power molding connector. Pin assignments are provided: Pin 1 (P1) is for V(+) and is red, Pin 2 (P2) is for Shield, Pin 3 (P3) is for GND(-) and is black, and Pin 4 (P4) is not specified but implied to be part of the connector. Heat-shrink tubing is indicated for cable protection.