R. STAHL 8530/1-MCB-STA101-C10-500-2 Line Protection Circuit Breaker
This document provides technical specifications for the R. STAHL 8530/1-MCB-STA101-C10-500-2 line protection circuit breaker.
Product Overview
The R. STAHL 8530 series circuit breakers offer excellent current limitation for short circuits and high switching capacities of 10, 15, or 25 kA. They are designed for minimal load on lines and high selectivity to upstream fuses. These components are modular and available in 1 to 4 pole versions with nominal currents from 0.5–63 A. The maximum installation capacity is 4.5 partial units (UP).
Key features include:
- Disconnecting function according to EN 60947-2
- Energy limitation class 3
- Easy replacement or system extension due to modular design
- Simple mounting by clipping onto a DIN rail in Ex e enclosures
- Fixed thermal-magnetic releases
- Ergonomic control lever for safe operation and shutdown
- Padlock protection (accessories) to prevent restarting during maintenance
Technical Characteristics
Explosion Protection
Characteristic | Value |
---|---|
Application area (zones) | 1, 2 |
Application area (zones) Avis | Usable in Zone 21 / 22 with protection by Ex tb / tc enclosure |
IECEx gas certificate | IECEX FMG 19.0029U |
IECEx protection against gas explosion | Ex db eb IIC Gb |
ATEX gas certificate | FM19ATEX0191U |
ATEX protection against gas explosion | II 2G Ex db eb IIC Gb |
Certificates | ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM) |
Certificate of conformity | Certificate of conformity (ATEX) |
Electrical Characteristics
Characteristic | Value |
---|---|
Rated operational voltage AC | 230 V |
Rated service current | 10 A |
Frequency | 50/60 Hz |
Rated switching capacity | 10 kA |
Electrical service life | 2 x 104 |
Mechanical service life | 2 x 104 |
1st auxiliary function | Auxiliary contact 1 changeover + signal contact 1 changeover |
Voltage 1st auxiliary function AC | 230 V |
Max. current 1st auxiliary function | 2 A |
2nd auxiliary function | none |
Max. voltage 2nd auxiliary function DC | - |
Tripping characteristic | C |
Number of poles | 1 pole |
Ambient Conditions
Characteristic | Value |
---|---|
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 158 °F |
Ambient temperature | -40°F ... +158°F |
Ambient temperature Avis | Ambient temperatures differing based on current certificates, on request |
Mechanical Characteristics
Characteristic | Value |
---|---|
Degree of protection (IP) (IECI 60529) | IP2X |
Enclosure material | Thermoplastic |
Connection terminal minimum cross-section | 1.5 mm² |
Connection terminal maximum cross-section | 25 mm² |
Connection terminal AWG min. cross-section | 16 AWG |
Connection terminal AWG max. cross-section | 4 AWG |
Connection terminal 2 min. cross-section | 1.5 mm² |
Connection terminal 2 max. cross-section | 10 mm² |
Connection terminal 2 AWG min. cross-section | 16 AWG |
Connection terminal 2 AWG max. cross-section | 8 AWG |
Auxiliary connection terminal min. cross-section | 0.5 mm² |
Auxiliary connection terminal max. cross-section | 4 mm² |
Auxiliary connection terminal AWG min. cross-section | 18 (unece.unit.AWG) |
Auxiliary connection terminal AWG max. cross-section | 14 (unece.unit.AWG) |
Minimum tightening torque | 2 N·m |
Maximum tightening torque | 3 N·m |
Connection terminal Avis | Connection of 2 conductors (upper and lower chamber simultaneously): Upper and lower chamber max. 16 / 10 mm² (Connection can be made with a maximum section difference between the upper and lower chamber.) |
Dimensions
Dimension | Value |
---|---|
Width | 65 mm |
Width in inches | 2.56 in |
Length | 165 mm |
Length in inches | 6.5 in |
Mounting depth | 138.3 mm |
Mounting depth in inches | 5.44 in |
Weight | 1 kg |
Weight | 2.205 lb |
Mounting / Installation
Characteristic | Value |
---|---|
Tightening torque | 2-3 N·m |
Tightening torque in lbf-in | 17.7 ... 26.6 lbf-in |
Auxiliary contact tightening torque | 0.4 – 0.6 Nm |
Auxiliary contact tightening torque in lbf-in | 3.5 ... 5.3 lbf-in |
Technical Drawings
Technical drawings and dimensions are provided, subject to modification.
- Tripping characteristic curve: A graph illustrating tripping behavior based on multiples of the rated current (In) for AC and DC.
- Dimensional drawing: Shows the overall dimensions of the circuit breaker, including width, length, and mounting depth, with both metric and imperial measurements.
Accessories
Available accessories enhance the functionality and installation of the circuit breaker.
- Quadruple locking device (Art. No. 227232): A locking/unlocking system that allows individual component locking using up to 4 cylinder locks.
- Fixing kit (Art. No. 276618): A kit for fixing the component onto a mounting plate without a DIN rail.
- Cylinder lock (Art. No. 107115): For locking (shackle Ø 3).
Note: Technical specifications, dimensions, weights, construction types, and delivery possibilities are subject to change. Figures are for illustrative purposes only.
For further information, contact R. STAHL Schaltgeräte GmbH.