R. STAHL 8530/1-MCB-STA101-C16-500-2 Line Protection Circuit Breaker
Product Overview
The R. STAHL 8530/1-MCB-STA101-C16-500-2 is a line protection circuit breaker designed for system technology applications. It offers high current limitation for short circuits and a high switching capacity of 10, 15, or 25 kA, ensuring minimal load on lines and high selectivity to upstream fuses. The components are modular and available in 1 to 4 pole versions with nominal currents from 0.5–63 A. The maximum installation capacity is 4.5 partial units (UP).
Key Features
- Disconnecting function according to EN 60947-2
- Energy limitation class 3
- Easy replacement or extension of existing systems due to modular design
- Simple snap-on mounting on a DIN rail in Ex e enclosures
- Fixed thermal-magnetic releases
- Ergonomic control lever for safe operation and shutdown
- Padlock protection (accessories) prevents re-operation during maintenance
Technical Specifications
Explosion Protection
Characteristic | Value |
---|---|
Application area (zones) | 1, 2 |
Application area (zones) Avis | Usable in zone 21 / 22 with protection via Ex tb / tc enclosure |
IECEx gas certificate | IECEx FMG 19.0029U |
IECEx gas explosion protection | Ex db eb IIC Gb |
ATEX gas certificate | FM19ATEX0191U |
ATEX gas explosion protection | II 2G Ex db eb IIC Gb |
Certificates | ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM) |
Conformity certificate (ATEX) | Conformity certificate (ATEX) |
Electrical Characteristics
Characteristic | Value |
---|---|
Rated operational voltage AC | 230 V |
Rated service current | 16 A |
Frequency | 50/60 Hz |
Rated switching capacity | 10 kA |
Electrical service life | 2 x 10⁴ |
Mechanical service life | 2 x 10⁴ |
1st auxiliary function | Auxiliary contact: 1 changeover contact + 1 signal contact: 2 changeover contacts |
Voltage 1st auxiliary function AC | 230 V |
Max. current 1st auxiliary function | 2 A |
2nd auxiliary function | None |
Max. voltage 2nd auxiliary function DC | - |
Tripping characteristic | C |
Number of poles | 1 pole |
Ambient Conditions
Characteristic | Value |
---|---|
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 158 °F |
Ambient temperature | -40°F ... +158°F |
Ambient temperature Avis | Ambient temperatures different from current certificates, on request |
Mechanical Characteristics
Characteristic | Value |
---|---|
Degree of protection (IP) (IECI 60529) | IP2X |
Housing material | Thermoplastic |
Minimum connection terminal size | 1.5 mm² |
Maximum connection terminal size | 25 mm² |
Minimum AWG connection terminal size | 16 AWG |
Maximum AWG connection terminal size | 4 AWG |
Minimum connection terminal size 2 | 1.5 mm² |
Maximum connection terminal size 2 | 10 mm² |
AWG connection terminal size 2 min. | 16 AWG |
AWG connection terminal size 2 max. | 8 AWG |
Min. connection terminal for aux. contact | 0.5 mm² |
Max. connection terminal for aux. contact | 4 mm² |
Min. AWG connection terminal for aux. contact | 18 (unece.unit.AWG) |
Max. AWG connection terminal for aux. contact | 14 (unece.unit.AWG) |
Minimum tightening torque | 2 N·m |
Maximum tightening torque | 3 N·m |
Connection terminal note | Connection of 2 conductors (upper and lower chamber simultaneously): Upper and lower chamber max. 16 / 10 mm² (Connection can be made with a maximum section difference between the upper and lower chamber.) |
Width | 65 mm (2.56 in) |
Length | 165 mm (6.5 in) |
Mounting depth | 138.3 mm (5.44 in) |
Weight | 1 kg (2.205 lb) |
Mounting / Installation
Characteristic | Value |
---|---|
Tightening torque | 2–3 N·m (17.7 ... 26.6 lbf·in) |
Tightening torque for auxiliary contact | 0.4–0.6 Nm (3.5 ... 5.3 lbf·in) |
Technical Drawings
Tripping Characteristic Curve C
Diagram showing tripping time in seconds versus multiples of rated current (I/In) for AC and DC, with a curve labeled "limite à partir de l'état froid".
Outline Drawing
Diagrams showing the dimensions of the circuit breaker in millimeters and inches, including width, height, and depth.
Accessories
Quadruple locking device
A locking/unlocking system that allows individual locking of the component using up to 4 cylinder locks. Part No. 227232
Fixing Kit
A fixing kit to attach the component to the mounting plate without a DIN rail. Part No. 276618
Cylinder Lock
For locking (shackle Ø 3). Part No. 107115
Subject to technical modifications, dimensions, weights, construction types, and delivery possibilities. Figures are for illustrative purposes only.
R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG | Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com