Schneider Electric TeSys Deca LC1D09M7 IEC Contactor
Product data sheet for the TeSys Deca LC1D09M7 IEC contactor.
Specifications
Product: IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open style
Device short name: LC1D
Contactor application: Motor control
Utilisation category: AC-4, AC-3, AC-1, AC-3e
Poles description: 3P
[Ue] rated operational voltage: Power circuit ≤ 690 V AC 25...400 Hz, Power circuit ≤ 300 V DC
[le] rated operational current: 9 A (at ≤ 60 °C) at ≤ 440 V AC AC-3 for power circuit, 25 A (at ≤ 60 °C) at ≤ 440 V AC AC-1 for power circuit, 9 A (at ≤ 60 °C) at ≤ 440 V AC AC-3e for power circuit
[Uc] control circuit voltage: 220 V AC 50/60 Hz
Complementary
Motor power kW: 2.2 kW at 220...230 V AC 50/60 Hz (AC-3), 4 kW at 380...400 V AC 50/60 Hz (AC-3), 4 kW at 415...440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660...690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4), 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e), 4 kW at 380...400 V AC 50/60 Hz (AC-3e), 4 kW at 415...440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating: 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility code: LC1D
Pole contact composition: 3 NO
Protective cover: With
[Ith] conventional free air thermal current: 25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for signalling circuit
Electrical Characteristics
Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 105 A at 40 °C - 10 s for power circuit, 210 A at 40 °C - 1 s for power circuit, 30 A at 40 °C - 10 min for power circuit, 61 A at 40 °C - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at ≤ 690 V coordination type 1 for power circuit, 20 A gG at ≤ 690 V coordination type 2 for power circuit
Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole: 1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e
[Ui] rated insulation voltage: Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 6 kV IEC 60947
Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability: 15 Mcycles
Electrical durability: 0.6 Mcycles 25 A AC-1 ≤ 440 V, 2 Mcycles 9 A AC-3 ≤ 440 V, 2 Mcycles 9 A AC-3e ≤ 440 V
Control circuit type: AC 50/60 Hz standard
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.3...0.6 Uc (drop-out AC 50/60 Hz), 0.8...1.1 Uc (operational AC 50 Hz), 0.85...1.1 Uc (operational AC 60 Hz), 1...1.1 Uc (operational AC 50/60 Hz)
Inrush power in VA: 70 VA 60 Hz cos φ 0.75 (at 20 °C), 70 VA 50 Hz cos φ 0.75 (at 20 °C)
Hold-in power consumption in VA: 7.5 VA 60 Hz cos φ 0.3 (at 20 °C), 7 VA 50 Hz cos φ 0.3 (at 20 °C)
Heat dissipation: 2...3 W at 50/60 Hz
Operating time: 12...22 ms closing, 4...19 ms opening
Maximum operating rate: 3600 cyc/h at 60 °C
Connections and Terminals
Connections - terminals:
- Power circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end
- Power circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end
- Power circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end
- Power circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end
- Power circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end
- Power circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end
- Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end
- Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end
- Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end
- Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end
- Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end
- Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end
Tightening torque: Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition: 1 NO + 1 NC
Auxiliary contacts type: Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency: 25...400 Hz
Minimum switching voltage: 17 V for signalling circuit
Minimum switching current: 5 mA for signalling circuit
Insulation resistance: > 10 MOhm for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact
Mounting Support: Plate, Rail
Environment
Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, IEC 60335-1:Clause 30.2, IEC 60335-2-40:Annex JJ, UL 60335-2-40:Annex JJ, CSA C22.2 No 60947-4-1
Product Certifications: UL, CCC, CSA, Marine, UKCA, EAC, CB Scheme
IP degree of protection: IP20 front face IEC 60529
Protective treatment: TH IEC 60068-2-30
Climatic withstand: IACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device: -40...140 °F (-40...60 °C), 140...158 °F (60...70 °C) with derating
Operating altitude: 0...9842.52 ft (0...3000 m)
Fire resistance: 1562 °F (850 °C) IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz), Vibrations contactor closed 4 Gn, 5...300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Dimensions
Height: 3.03 in (77 mm)
Width: 1.8 in (45 mm)
Depth: 3.4 in (86 mm)
Product Weight: 0.71 lb(US) (0.32 kg)
Dimensions Drawings:
A diagram showing the dimensions of the contactor with different configurations (e.g., with add-on blocks, with specific auxiliary contact modules). Key dimensions labeled as b, b1, c, c1, c2, c3.
Table of Dimensions (mm):
D09...D18 | D093...D123 | D099...D129 | |
b without add-on blocks | 77 | 80 | 88 |
b with LAD 4BB | 99 | 94 | 95.5 |
b1 with LA4 D.2 | 110(1) | 123(1) | 111.5(1) |
b1 with LA4 DF, DT | 119(1) | 132(1) | 120.5(1) |
b1 with LA4 DW, DL | 126(1) | 139(1) | 127.5(1) |
c without cover or add-on blocks | 84 | 84 | 84 |
c with cover, without add-on blocks | 86 | 86 | 86 |
c1 with LAD N or C (2 or 4 contacts) | 117 | 117 | 117 |
c2 with LA6 DK10, LAD 6K10 | 129 | 129 | 129 |
c3 with LAD T, R, S | 137 | 137 | 137 |
c3 with LAD T, R, S and sealing cover | 141 | 141 | 141 |
(1) Including LAD 4BB.
Assembly's dimensions: Diagram showing the overall dimensions of the contactor with AC and DC coils, indicating height, width, and depth in inches and millimeters.
Ordering and Shipping Details
Category: US1011222354
Discount Schedule: 0112
GTIN: 3389110348873
Returnability: Yes
Country of origin: SG
Packing Units:
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 1.97 in (5.000 cm)
Package 1 Width: 3.62 in (9.200 cm)
Package 1 Length: 4.53 in (11.500 cm)
Package 1 Weight: 12.346 oz (350.000 g)
Unit Type of Package 2: S02
Number of Units in Package 2: 20
Package 2 Height: 5.91 in (15.000 cm)
Package 2 Width: 11.81 in (30.000 cm)
Package 2 Length: 15.75 in (40.000 cm)
Package 2 Weight: 16.054 lb(US) (7.282 kg)
Unit Type of Package 3: P06
Number of Units in Package 3: 320
Package 3 Height: 29.53 in (75.000 cm)
Package 3 Width: 23.62 in (60.000 cm)
Package 3 Length: 31.50 in (80.000 cm)
Package 3 Weight: 272.271 lb(US) (123.500 kg)
Contractual warranty:
Warranty: 18 months
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via their ongoing "Use Better, Use Longer, Use Again" campaign to extend product lifetimes and recyclability.
Environmental footprint: Carbon footprint (kg CO2 eq, Total Life cycle): 18
Materials and Substances:
- Packaging made with recycled cardboard: Yes
- Packaging without single use plastic: Yes
- EU RoHS Directive: Compliant
- REACH Regulation: REACH Declaration
- California proposition 65: WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
- PVC free: Yes
Repack and remanufacture:
- Circularity Profile: End of Life Information
- Take-back: No
- WEEE: The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Benefits / Features
TeSys Deca Contactors
Rated operation current (AC3): 9A
Number of poles: 3P (3NO)
Auxiliary contact composition: 1 NO + 1 NC
Coil voltage: 220 V AC
Network frequency: 50/60Hz
Technical Illustration
Diagrams illustrating the physical dimensions and assembly of the LC1D09M7 contactor with both AC and DC coils.
Wiring Diagram
A schematic showing the wiring connections for the contactor, indicating terminal designations.