Spesifikasi:

  • Model: AIRING-2000
  • ukuran: 228x115x70mm (9×4.5×2.8 in)
  • Kapasitas baterei: 3500mAh
  • Urip baterei: 4 jam
  • Output pengisian: DC5V, 2A
  • Range Deteksi PM2.5: 0-999 μg/m³
  • Range Deteksi PM10: 0-999 μg/m³
  • Range Deteksi Kelembapan: 0-100%

Pandhuan Panggunaan Produk

  1. Daya ON
    Pencet terus tombol daya nganti 2 detik kanggo nguripake detektor. Sawise inisialisasi, instrumen mlebu antarmuka standar tanpa miwiti pangukuran kanggo ngirit daya.
  2. Miwiti Deteksi
    Pencet tombol ukuran / ngenteni kanggo miwiti deteksi, nampilake data wektu nyata kabeh paramèter. Instrumen standar dadi s terusampling. Pencet tombol sing padha kanggo ngaso sampling
  3. Ngalih Item Pangukuran
    Data PM2.5 standar ditampilake ing utama view kothak. Gunakake tombol munggah utawa mudhun kanggo ngalih ing antarane item pangukuran sing ditampilake ing utama view kothak.
  4. Setelan Menu
    Pencet tombol menu kanggo ngetik layar menu. Gunakake tombol munggah utawa mudhun kanggo ngalih ing antarane pilihan, banjur pencet tombol OK kanggo konfirmasi pilihan sampeyan viewing utawa ngganti setelan.
  5. Setelan Sistem
    Ing antarmuka setelan sistem, navigasi menyang MENU-> Setelan kanggo nyetel wektu, sample, pangaturan lampu latar, lan pilihan basa. Gunakake tombol munggah utawa mudhun kanggo ngalih opsi lan penet OK kanggo ngetik.
    1. Setelan Wektu
      Ing antarmuka setelan wektu, gunakake tombol kanggo nyetel setelan wektu. Pencet OK kanggo nyimpen setelan yen wis rampung.
    2. Samplan Setelan
      Ing sampantarmuka setelan, nyetel Unit Suhu, Interval Panyimpenan, lan Setelan Warning yen perlu.

Pambuka

AIRING-2000 minangka monitor massa partikel genggam sing cilik, entheng, bertenaga baterei, multi-fungsi. Jumlah output telung saluran yaiku 0.3µm, 0.5µm, lan 1.0µm, partikel partikel. Uga nduweni fitur PM2.5, PM10, TSP, suhu lan kelembapan, lan data historis.

Tampilan layar gedhe lan operasi pitung tombol iku prasaja lan efisien, dadi cocok kanggo tes cepet ing macem-macem skenario. Baterei lithium kinerja dhuwur sing dibangun ngidini piranti bisa terus-terusan nganti paling sethithik 4 jam. Sauntara, AIRING-2000 duwe 32GB panyimpenan sing dibangun supaya data tes bisa viewed langsung ing tampilan utawa nggunakake USB kelet kanggo ngekspor menyang PC liwat port USB kanggo viewing lan analisis.

Penting!

  • Aja nyedhiyakake detektor ing lingkungan sing akeh kontaminasi kanggo wektu sing suwe, amarga bisa ngrusak sensor.
  • Aja teka menyang kontak karo pelarut organik, kang kalebu silika gel lan adhesives liyane, lukisan, obatan, lenga lan gas konsentrasi dhuwur.
  • Aja nggunakake detektor ing lingkungan sing lembab kanggo njaga akurasi deteksi.
  • Aja nutupi inlet/outlet udhara nalika nggunakake detektor.
  • Aja mbongkar unit dhewe. Yen ana cacat, hubungi dealer sampeyan, sing bakal sesambungan karo pusat layanan lan, yen perlu, ngirim piranti kanggo ndandani.
  • Anak mung kudu nggunakake piranti iki ing pengawasan wong diwasa. Simpen bahan kemasan, kayata tas plastik lan bungkus plastik, supaya ora bisa digayuh bocah amarga mbebayani.

Swaraview

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (1)

  1. Saluran Deteksi Suhu & Kelembapan
  2. Layar LCD
  3. Tombol Daya
  4. Tombol mburi
  5. Tombol OK
  6. Saluran Intake
  7. Port USB
  8. JENIS-C Pelabuhan
  9. Tombol Ukur / Enteni
  10. Tombol Menu
  11. Tombol Munggah
  12. Tombol mudhun
  13. Outlet udara
  14. Bracket Hooks

Spesifikasi

Model AIRING-2000
ukuran 228x115x70mm(9×4.5×2.8 in)
Kapasitas baterei 3500mAh
Urip baterei > 4h
Output Pengisian DC5V, 2A
 

PM2.5

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

 

PM10

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

 

TSP

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

0.3µm, 0.5µm, 1.0µm Range: 0-999999 P/L

Resolusi: 1 P/L Akurasi: ± 30%

Suhu Range: 0-50°C (32-122°F)

Resolusi: 0.1°C Akurasi: ±0.5°C (±0.9°F)

Kelembapan Range: 0-90% RH

Resolusi: 0.1% Akurasi: ± 5% RH

Cathetan: Data ing nginggil menika saking Laboratorium Temtop.

  • Range: 0-9999.9μg/m3 Resolusi: 0.1μg/m3
  • Akurasi: ±10μg/m3 (0-100μg/m3), ±10% (>100μg/m3)
  • Range: 0-9999.9μg/m3 Resolusi: 0.1μg/m3
  • Akurasi: ±10μg/m3 (0-100μg/m3), ±10% (>100μg/m3)

Pènget!

  • Panggunaan njero ruangan: Tansah kedap udara ruangan / area sajrone 10 menit kanggo entuk asil sing luwih akurat.
  • Yen level baterei katon, mangga ngisi detektor kanthi cepet supaya ora ana efek nalika digunakake (uga bisa diisi daya nalika dipateni). 76.5 ° F 54.4% RH

Daya ON

  • Pencet terusTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (2) tombol kanggo 2 detik kanggo nguripake detector.
  • Sawise inisialisasi, instrumen mlebu ing antarmuka standar.
  • Ora bakal miwiti pangukuran kanthi standar kanggo ngirit daya (Fig.2).TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (3)
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (4) kanggo miwiti deteksi, lan bakal nampilake data wektu nyata kabeh paramèter. Instrumen standar dadi s terusampling. Sajrone sampproses ling, sampeyan bisa mencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (4) ngaso sampling (Gbr.3).TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (5)
  • Data PM2.5 standar instrument ditampilake ing utama view kothak, tekan TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih item pangukuran sing ditampilake ing utama view kothak (Fig.4).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (8)

Setelan Menu

  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngetik layar menu, banjur penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih ing antarane pilihan.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo konfirmasi pilihan kanggo view utawa ngganti setelan (Fig.5).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (11)

Pilihan MENU kaya ing ngisor iki:

Menu Tampilake minangka… Katrangan
Setelan Sistem Setelan Setel wektu sistem, sampling, lampu latar, lan basa.
Kalibrasi Sistem Kalibrasi Kalibrasi nul, lan k-Factor.
Riwayat Data Sajarah Njaluk, ngundhuh lan mbusak data.
Sistem Informasi Informasi Tampilan informasi sistem.

Setelan Sistem
Ing antarmuka setelan sistem MENU-> Setelan, sampeyan bisa nyetel wektu, sample, pangaturan lampu latar, lan basa. Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) kanggo ngalih pilihan (Fig.6) lan penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo mlebu.
TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (12)

Setelan Wektu
Tekan ing TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)tombol kanggo ngetik antarmuka setelan wektu, penet ingTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) tombol kanggo ngalih pilihan, penet ing TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) tombol kanggo nambah utawa nyuda nilai, ngalih menyang Simpen pilihan nalika setelan wis rampung, penet tombolTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)tombol kanggo nyimpen setelan (Fig. 7).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (13)

Samplan Setelan
Ing antarmuka setelan sistem MENU-> Setelan, penet utawa kanggo ngalih menyang tombol Sample Setelan, banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) kanggoTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) mlebu sampantarmuka setelan (Fig.8). Ing sampantarmuka setelan sampeyan bisa nyetel Unit Suhu, Interval Storage lan Setelan Warning.

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (14)

Unit Suhu

  • Ing antarmuka setelan sistem MENU->Setelan->Sample.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo ngetik antarmuka Unit Suhu.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo milih °C utawa °F.
  • Banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)kanggo ngalih menyang Simpen banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo nyimpen (Fig.9).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (15)

Interval panyimpenan

  • Ing antarmuka setelan sistem MENU->Setelan->Sample.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih menyang Interval Storage, lan Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo mlebu.
  • Interval panyimpenan 1min, 2min, 5min, 10min, 15min, 30min lan 60min iku opsional.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)tombol kanggo ngalih interval panyimpenan.
  • Banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)kanggo ngalih menyang Simpen banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo nyimpen (Fig.10).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (16)

Setelan Warning

  • Ing antarmuka setelan sistem MENU->Setelan->Sample.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih menyang Setelan Warning, lan PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo mlebu. Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)kanggo milih ngalih weker urip utawa mati.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo milih PM2.5, PM10, TSP, 0.3μm, 0.5μm, lan 1.0μm, tekan TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo milih item modifikasi banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)kanggo ngowahi nilai sing diowahi, banjur penet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngowahi batesan weker.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih menyang Simpen nalika setelan wis rampung banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo nyimpen (Fig.11).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (17)

Cathetan: Setelan gawan pabrik produk bakal dibalèkaké nalika setelan gawan digawe.

Imbuhan Backlight

  • Ing antarmuka setelan sistem MENU-> Setelan.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih menyang Imbuhan Lampu Latar, banjur penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo mlebu.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)kanggo milih 1, 2 lan 3.
  • Banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngalih menyang Simpen banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo nyimpen (Fig.12).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (18)

Cathetan: Tingkat lampu latar layar standar pabrik yaiku 3.

Setelan Basa

  • Ing antarmuka setelan sistem MENU-> Setelan.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih menyang Setelan Basa, banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo mlebu.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)kanggo milih Inggris utawa 中文.
  • Banjur presTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)s kanggo ngalih menyang Simpen banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo nyimpen (Fig.13).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (19)

Kalibrasi Sistem

  • Ing antarmuka sistem kalibrasi MENU-> Kalibrasi, sampeyan bisa operate Zero Kalibrasi lan K-Factor Kalibrasi.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih pilihan banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo mlebu (Fig.14).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (20)

Kalibrasi Nol

  • Ing antarmuka Zero Calibration, penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo miwiti calibrating.
  • Butuh kira-kira 90 detik countdown. Sawise countdown rampung, tampilan njaluk pangeling kanggo konfirmasi kalibrasi rampung kasil lan bakal bali menyang antarmuka MENU-Kalibrasi otomatis (Fig. 15).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (21)

Kalibrasi K-Factor

  • Priksa manawa piranti kasebut ana ing lingkungan sing stabil.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo nindakake kalibrasi konsentrasi massa K-faktor. Produk bakal nguripake pompa lan ngumpulake data sajrone 60 detik, banjur nerusake menyang layar Kalibrasi Konsentrasi Massa Faktor K.
  • PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngoper kursor, penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo milih item modifikasi, banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngowahi nilai sing diowahi, banjur penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo nambah utawa nyuda regane.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih kanggo kalibrasi sawise setelan rampung, penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo kalibrasi (Fig.16).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (22)

Cathetan: Setelan gawan pabrik produk bakal dibalèkaké nalika setelan gawan digawe.

Riwayat Data

  • Ing antarmuka riwayat data MENU-> Sejarah, sampeyan bisa ngoperasikake Query Data, Ngundhuh Riwayat lan Pambusakan Sejarah.
  • Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih pilihan banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo mlebu (Fig.17).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (23)

Pitakonan Data

  • Ing antarmuka query, sampeyan bisa menet data sasi. PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngetik antarmuka pilihan sasi, kanthi standar sistem bakal kanthi otomatis menehi rekomendasi sasi saiki.
  • Yen sampeyan butuh data kanggo sasi liyane, sampeyan bisa mencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo nambah utawa nyuda regane. Yen wis rampung, pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngalih menyang pitakon banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo ngetik pitakonan (Fig.18).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (24)

Sajarah Download
Ing antarmuka Download History, lebokake piranti USB kayata USB flash drive utawa maca kertu menyang port USB ing monitor, Yen piranti USB kasil disambungake, penetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo ngundhuh data (Fig. 19).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (25)

Sawise ndownload data, copot piranti USB lan lebokake menyang komputer kanggo nemokake folder sing diawali karo nomer seri produk, contone.amplan, "TT1246070001-062120241754". Sampeyan bisa view lan analisis data saiki. Yen piranti USB gagal disambungake utawa ora ana piranti USB sing disambungake, tampilan bakal menehi pangeling. Mangga sambungake maneh utawa coba maneh mengko (Fig. 20).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (26)

Pambusakan Riwayat
Ing antarmuka Pambusakan Riwayat, data bisa dibusak miturut sasi utawa kabeh. Pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo ngalih opsi banjur pencet TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo mlebu (Fig. 21).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (27)

Miturut Wulan
Kanggo antarmuka Data Bulanan, sasi saiki bakal ditampilake kanthi otomatis kanthi gawan. Yen sampeyan kudu mbusak sasi liyane, pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) ngalih menyang opsi taun lan sasi, banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) kanggo nambah utawa nyuda regane. Sawise rampung, pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) kanggo ngalih menyang Busak banjur pencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)kanggo ngrampungake mbusak (Fig.22).
TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (28)Kabeh Data
Kanggo layar Kabeh Data, tampilan bakal njaluk 'Apa sampeyan yakin arep mbusak data?' PencetTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) kanggo konfirmasi pambusakan (Fig. 23). Ngenteni pambusakan rampung, yen data wis kasil dibusak tampilan bakal njaluk pangeling lan kanthi otomatis bali menyang layar Menu-History.

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (29)

Sistem Informasi
Antarmuka Sistem Informasi nuduhake informasi ing ngisor iki (Fig.24)

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (30)

Daya OFF
Pencet terusTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (2) kanggo 2 detik kanggo mateni monitor (Fig.25).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (31)

Apa Klebu

  • Detektor x 1
  • Kabel USB x 1
  • Manual pangguna x 1
  • Sertifikat Kalibrasi x 1
  • Pangisi daya baterei (Kalebu 4 adaptor)* x 1

Skema Pangisi daya baterei lan Operasi Example:

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (32)

Example:

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (33)

  1. Instalasi:
    Tahan "Snap Switch" ing tangan kiwa lan nguripake ing "KUNCI” arah karo tangan tengen.
  2. mbusak:
    Tahan "Snap Switch" ing tangan kiwa lan nguripake ing "BUKA” arah karo tangan tengen.

Ngatasi masalah

Gagal Kemungkinan Penyebab Solusi
 

rame

Alirane kakehan Kalibrasi aliran
Pompa rusak Kirim menyang pusat layanan
Ora bisa diuripake, ora ana tampilan Baterei kosong Ngisi daya baterei kanggo 3.5 h
Baterei rusak Kirim menyang pusat layanan
Tampilan urip, nanging pump ora mbukak Tingkat baterei sithik Ngisi daya baterei kanggo 3.5 h
Pompa rusak Kirim menyang pusat layanan
 

 

Nilai sing dideteksi ora bisa dipercaya

Penyimpangan aliran Kalibrasi aliran
Layar mlebu clogged Priksa layar mlebu
 

Kontaminasi ing njero monitor

Ganti unsur panyaring
Kirim menyang pusat layanan
Ora bisa ngisi daya batere Baterei rusak Kirim menyang pusat layanan
Gagal pangisi daya Hubungi pusat layanan

Garansi

Temtop njamin detektor sing kalebu sajrone 1 taun wiwit tanggal tuku asli. Item bisa diijolke utawa bali ing 30 dina yen cacat ora disebabake karusakan gawean.

Item Periode babar pisan
Detektor 1 taun klebu
Aksesoris N/A

Sadurunge bali utawa dikirim kanggo ndandani, priksa manawa barang √ ing ngisor iki wis siyap:

  Detektor &

Aksesoris

Paket Lengkap Bukti Pembelian* Hadiah (yen ana)
wangsul
Ijol-ijolan  
ndandani    

* Kalebu invoice, nomer pesenan lan liya-liyane.

Garansi Temtop ora kalebu:

  • Malfungsi utawa karusakan sing disebabake dening karusakan utawa modifikasi gawean.
  • Kerusakan liyane sing disengaja.
  • Kerusakan sing disebabake dening kedadeyan alam.

Elitech Teknologi, Inc

Elitech Brazil Ltda

Elitech (UK) Winates

Made In China

FAQ

P: Kepiye cara ngisi AIRING-2000?
A: AIRING-2000 bisa diisi daya nalika dipateni nggunakake pangisi daya DC5V, 2A liwat port TYPE-C.

P: Apa umur baterei AIRING-2000?
A: Kapasitas baterei AIRING-2000 yaiku 3500mAh, nyedhiyakake umur baterei kira-kira 4 jam.