TEMTOP AIRING-2000 Handheld Particle Counter Particulate Monitor

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-PRODUCT

Specifications:

  • Model: AIRING-2000
  • Dimensions: 228x115x70mm (9×4.5×2.8 in)
  • Battery Capacity: 3500mAh
  • Battery Life: 4 hours
  • Charging Output: DC5V, 2A
  • PM2.5 Detection Range: 0-999 μg/m³
  • PM10 Detection Range: 0-999 μg/m³
  • Humidity Detection Range: 0-100%

Product Usage Instructions

  1. Power ON
    Press and hold the power button for 2 seconds to turn on the detector. After initialization, the instrument enters the default interface without starting the measurement to save power.
  2. Start Detection
    Press the measure/wait button to start detection, displaying real-time data of all parameters. The instrument defaults to continuous sampling. Press the same button to pause sampling.
  3. Switch Measurement Items
    The default PM2.5 data is displayed in the main view box. Use the up or down buttons to switch between measurement items displayed in the main view box.
  4. Setting Menu
    Press the menu button to enter the menu screen. Use the up or down buttons to toggle between options, and then press the OK button to confirm your choice for viewing or changing settings.
  5. System Setting
    In the system setting interface, navigate to MENU->Setting to set time, sample, backlight adjustment, and language preferences. Use the up or down buttons to switch options and press OK to enter.”
    1. Time Setting
      In the time setting interface, use the buttons to adjust time settings. Press OK to save the settings when finished.
    2. Sample Setting
      In the sample setting interface, set Temperature Unit, Storage Interval, and Warning Settings as needed.

Introduction

The AIRING-2000 is a small, lightweight, battery-powered, multi-functional handheld particulate mass monitor. Three channels output counts of 0.3µm, 0.5µm, and 1.0µm, particulate matter. It also features PM2.5, PM10, TSP, temperature and humidity, and historical data.

The large screen display and seven-button operation are simple and efficient, making it suitable for quick tests in various scenarios. The built-in high-performance lithium battery allows the instrument to run continuously for at least 4 hours. Meanwhile, the AIRING-2000 has 32GB of built-in storage so that test data can be viewed directly on the display or use a USB stick to export to a PC via the USB port for viewing and analysis.

Important!

  • Do not expose the detector to heavily contaminated environments for long periods, as this can damage the sensor.
  • Do not come into contact with organic solvents, whichinclude silica gel and other adhesives, paintings, drugs, oil and high-concentration gases.
  • Do not use the detector in a humid environment to maintain detection accuracy.
  • Do not cover the air inlet/outlet when using the detector.
  • Do not dismantle the unit yourself. In the event of a defect, contact your dealer instead, who will liaise with the service center and, if necessary, send the device in for repair.
  • Children should only use this device under adult supervision. Keep packaging materials, such as plastic bags and plastic wrap, out of the reach of children as they present a choking hazard.

Overview

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (1)

  1. Temperature & Humidity Detection Channel
  2. LCD Screen
  3. Power Button
  4. Back Button
  5. OK Button
  6. Intake Duct
  7. USB Port
  8. TYPE-C Port
  9. Measure/Wait Button
  10. Menu Button
  11. Up Button
  12. Down Button
  13. Air Outlet
  14. Bracket Hooks

Specifications

Model AIRING-2000
Dimensions 228x115x70mm(9×4.5×2.8 in)
Battery Capacity 3500mAh
Battery Life >4h
Charging Output DC5V, 2A
 

PM2.5

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

 

PM10

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

 

TSP

Range: 0-9999.9µg/m3 Resolution: 0.1µg/m3 Accuracy: ±10µg/m3 (0-100µg/m3),

±10% (>100µg/m3)

0.3µm, 0.5µm, 1.0µm Range: 0-999999 P/L

Resolution: 1 P/L Accuracy: ±30%

Temperature Range: 0-50°C (32-122°F)

Resolution: 0.1°C Accuracy: ±0.5°C (±0.9°F)

Humidity Range: 0-90%RH

Resolution: 0.1% Accuracy: ±5%RH

Note: The above data are from Temtop Laboratory.

  • Range: 0-9999.9μg/m3 Resolution: 0.1μg/m3
  • Accuracy: ±10μg/m3 (0-100μg/m3), ±10% (>100μg/m3)
  • Range: 0-9999.9μg/m3 Resolution: 0.1μg/m3
  • Accuracy: ±10μg/m3 (0-100μg/m3), ±10% (>100μg/m3)

Warning!

  • Indoor use: Keep the room/area airtight for 10 minutes to obtain more accurate results.
  • If battery level shows , please charge the detector promptly to avoid effects during use (also chargeable when turned off). 76.5 °F 54.4%RH

Power ON

  • Press and holdTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (2) button for 2 seconds to turn on the detector.
  • After initialization, the instrument enters the default interface.
  • lt will not start the measurement by default to save the power (Fig.2).TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (3)
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (4) to start detection, and it will display the real-time data of all parameters. The instrument defaults to continuous sampling. During the sampling process, you can pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (4) to pause sampling (Fig.3).TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (5)
  • The instrument default PM2.5 data is displayed in the main view box, press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch the measurement items displayed in the main view box (Fig.4).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (8)

Setting Menu

  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to enter the menu screen, then pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to toggle between options.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to confirm your choice to view or change settings (Fig.5).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (11)

MENU options are as follows:

Menu Display as… Description
System Setting Setting Set system time, sampling, backlight, and language.
System Calibration Calibration Calibrate zero, and k-Factor.
Data History History Query, download and delete the data.
System Information Information Display system information.

System Setting
In the system setting interface MENU->Setting, you can set time, sample, backlight adjustment, and language. Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) to switch the options (Fig.6) and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter.
TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (12)

Time Setting
Press the TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)key to enter the time setting interface, press theTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) key to switch the option, press the TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) key to increase or decrease the value, switch to the Save option when the setting is completed, press theTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)key to save the setting (Fig. 7).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (13)

Sample Setting
In the system setting interface MENU->Setting, press or to switch to the Sample Setting, and then pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) toTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) enter the sample setting interface (Fig.8). In the sample setting interface you can set the Temperature Unit, Storage Interval and Warning Setting.

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (14)

Temperature Unit

  • In the system setting interface MENU->Setting->Sample.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to enter the Temperature Unit interface.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to select °C or °F.
  • Then press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)to switch to Save and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to save (Fig.9).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (15)

Storage Interval

  • In the system setting interface MENU->Setting->Sample.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to the Storage Interval, and Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to enter.
  • The storage interval 1min, 2min, 5min, 10min, 15min, 30min and 60min is optional.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)key to switch the storage interval.
  • Then press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)to switch to Save and press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to save (Fig.10).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (16)

Warning Setting

  • In the system setting interface MENU->Setting->Sample.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to the Warning Setting, and PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter. Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)to select the on or off alarm switch.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to select PM2.5, PM10, TSP, 0.3μm, 0.5μm, and 1.0μm, press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to select the modification item and press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)to toggle the modified value, then press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to modify the alarm threshold.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to Save when the setting is complete and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to save (Fig.11).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (17)

Note: The product factory default settings will be restored when the default settings are made.

Backlight Adjustment

  • In the system setting interface MENU->Setting.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to the Backlight Adjustment, and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)to select 1, 2 and 3.
  • Then pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to switch to Save and press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to save (Fig.12).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (18)

Note: The factory default screen backlight level is 3.

Language Setting

  • In the system setting interface MENU->Setting.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to the Language Setting, and press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to enter.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) or TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7)to select English or 中文.
  • Then presTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9)s to switch to Save and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to save (Fig.13).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (19)

System Calibration

  • In the system calibration interface MENU->Calibration, you can operate Zero Calibration and K-Factor Calibration.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch the option and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter (Fig.14).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (20)

Zero Calibration

  • Under the Zero Calibration interface, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to start calibrating.
  • It takes about 90 seconds countdown. After the countdown finishes, the display prompts a reminder to confirm the calibration finishes successfully and will return to the MENU-Calibration interface automatically (Fig. 15).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (21)

K-Factor Calibration

  • Make sure the instrument is in a stable environment.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to perform a K-factor mass concentration calibration. The product will turn on the pump and collect data for 60 seconds, then proceed to the K Factor Mass Concentration Calibration screen.
  • PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch the cursor, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to select the modification item, and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to toggle the modified value, then pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to increase or decrease the value.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch to calibrate after the setting is completed, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to calibrate (Fig.16).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (22)

Note: The product factory default settings will be restored when the default settings are made.

Data History

  • In the data history interface MENU->History, you can operate Data Query, History Download and History Deletion.
  • Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch the option and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter (Fig.17).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (23)

Data Query

  • In the query interface, you can press month data. PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to enter the month selection interface, by default the system will automatically recommend the current month.
  • If you need data for other months, you can pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to increase or decrease the value. When finished, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to switch to the query and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to enter the query (Fig.18).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (24)

History Download
In the History Download interface, insert a USB device such as a USB flash drive or card reader into the USB port of the monitor, If the USB device is successfully connected, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to download the data (Fig. 19).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (25)

After downloading the data, unplug the USB device and insert it into the computer to find a folder prefixed with the product serial number, for example, “TT1246070001-062120241754”. You can view and analyze the data now. If the USB device fails to connect or there is no USB device connected, the display will prompt a reminder. Please reconnect it or try again later (Fig. 20).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (26)

History Deletion
In the History Deletion interface, data can be deleted by month or all. Press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6)orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to switch options and press TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to enter (Fig. 21).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (27)

By Month
For the Monthly Data interface, the current month will auto display by default. lf you need to delete other months, please pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) switching to the year and month options, then pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (6) orTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (7) to increase or decrease the value. After complete, pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (9) to switch to Delete and pressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10)to complete the delete(Fig.22).
TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (28)All Data
For the All Data screen, the display will prompt ‘Are you sure you want to delete the data?’ PressTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (10) to confirm the deletion (Fig. 23). Wait for the deletion to complete, if the data has been successfully deleted the display will prompt a reminder and automatically return to the Menu-History screen.

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (29)

System Infomation
The System Infomation interface shows the following information (Fig.24)

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (30)

Power OFF
Press and holdTEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (2) for 2 seconds to turn off the monitor (Fig.25).

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (31)

What’s Included

  • Detector x 1
  • USB Cable x 1
  • User Manual x 1
  • Calibration Certificate x 1
  • Battery Charger (Includes 4 adapters)* x 1

Battery Charger Schematic and Operation Example:

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (32)

Example:

TEMTOP-AIRING-2000 Handheld-Particle-Counter-Particulate-Monitor-FIG- (33)

  1. Installation:
    Hold the “Snap Switch” in your left hand and turn it in the “LOCK” direction with your right hand.
  2. Removal:
    Hold the “Snap Switch” in your left hand and turn it in the “OPEN” direction with your right hand.

Troubleshooting

Failure Possible Causes Solution
 

Noise

The flow is excessive Flow calibration
The pump is faulty Send to the service center
Cannot be turned on, no display Battery discharged Charge the battery for 3.5 h
The battery is faulty Send to the service center
Display is on, but pump does not run Low battery level Charge the battery for 3.5 h
The pump is faulty Send to the service center
 

 

Detected value is not reliable

Flow deviation Flow calibration
Inlet screen clogged Check the inlet screen
 

Contamination inside the monitor

Replace the filter element
Send to the service center
Unable to charge the battery The battery is faulty Send to the service center
Charger failure Contact the service center

Warranty

Temtop warrants the included detector for 1 year from the date of original purchase. The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage.

Item Warranty Period
Detector 1 year included
Accessories N/A

Before return or delivery for repair, please check if the following √ items are ready:

  Detector &

Accessories

Complete Package Proof of Purchase* Gift (if any)
Return
Exchange  
Repair    

* Including invoice, order number and etc.

Temtop warranty does NOT include:

  • Malfunction or damages caused by artificial damage or modification.
  • Other deliberate damages.
  • Damage caused by natural events.

Elitech Technology, Inc

Elitech Brazil Ltda

Elitech (UK) Limited

Made In China

FAQ

Q: How do I charge the AIRING-2000?
A: The AIRING-2000 can be charged when turned off using a DC5V, 2A charger via the TYPE-C port.

Q: What is the battery life of the AIRING-2000?
A: The battery capacity of AIRING-2000 is 3500mAh, providing a battery life of approximately 4 hours.