logo PPIHumiTherm-cS
Advanced 'Suhu + Kelembapan'
Programmable Controller karo Weker
Manual pangguna

HumiTherm-cS Suhu Lanjut + Kelembapan Programmable Controller

Manual singkat iki utamané dimaksudaké kanggo referensi cepet sambungan kabel lan searching parameter. Kanggo rincian liyane babagan operasi lan aplikasi; mangga log on www.ppiindia.net

SAMBUNGAN LISTRIK

PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - KONEKSI ELEKTRIK

Majelis Enclosure

PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - RAKIT LAMPIRAN

MAJLIS DEWAN

Déwan elektronik kasusun saka papat Papan Sirkuit Cetak (PCB); CPU PCB, Tampilan PCB, Output PCB & Power Supply PCB. Tokoh ing ngisor iki nuduhake posisi saben PCB nang pager. PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - RAKIT PAPAN

SETTING JUMPER

PPI HumiTherm-cS Suhu Lanjut + Kontrol Kelembaban sing Bisa Diprogram - SETELAN JUMPERRincian MOUNTING
SERIAL COMM. MODULPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - DETAIL PASANGPARAMETER KONFIGURASI INPUT: PAGE 12

Paramèter Setelan
(Nilai Default)
Pilih SaluranPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 1 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 2Temp
Kelembapan
(Default: Suhu)
Tipe InputPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 3 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 4(Default: RTD)
Sinyal KurangPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 5
Tipe Input Setelan Default
0 nganti 20mA 0.00 kanggo Signal High 0.00
4 nganti 20mA 4.00 kanggo Signal High 4.00
0 kanggo 50mV 0.00 kanggo Signal High 0.00
0 kanggo 200mV 0.0 kanggo Signal High 0.0
0 kanggo 1.25 V 0.00 kanggo Signal High 0.00
0 kanggo 5 V 0.000 kanggo Signal High 0.000
0 kanggo 10 V 0.00 kanggo Signal High 0.00
1 kanggo 5 V 1.000 kanggo Signal High 1.000
Sinyal DhuwurPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 6
Tipe Input Setelan Default
0 nganti 20mA 20.00 kanggo Signal Low 20.00
4 nganti 20mA 20.00 kanggo Signal Low 20.00
0 kanggo 50mV 50.00 kanggo Signal Low 50.00
0 kanggo 200mV 200.0 kanggo Signal Low 200.0
0 kanggo 1.25 V 1.250 kanggo Signal Low 1.250
0 kanggo 5 V 5.000 kanggo Signal Low 5.000
0 kanggo 10 V 10.00 kanggo Signal Low 10.00
1 kanggo 5 V 5.000 kanggo Signal Low 5.000
Range LowPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 7 -199.9 nganti 999.9
(Default: 0.0)
Range DhuwurPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 8 -199.9 nganti 999.9
(Default: 100.0)
OffsetPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 9 -50.0 nganti 50.0
(Default: 0.0)

PARAMETER KONTROL : PAGE 11

Paramèter Setelan
(Nilai Default)
Pilih SaluranPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 1 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 2Temp
Kelembapan
(Default: Suhu)
Tindakan KontrolPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 10 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 11(Default: PID)
Watesan Low SetpointPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 12 Temp = -199.9°C nganti SP.Hi
RH = 0.0% kanggo SP.Hi
(Default: 0)
Watesan Tinggi SetpointPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 13 Suhu = SP.Lo nganti 600.0°C
RH = SP.Lo nganti 100.0%
(Default: 100)
Paramèter Setelan
(Nilai Default)
Kalor / Kelembapan Daya Low LimitPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 14 0.0% kanggo Power High Limit
(Default: 0.0)
Daya Panas / Kelembapan Batas DhuwurPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 15 Batesan Kurang Daya nganti 100.0%
(Default: 100.0)
Band proporsional
(Zona Pra-dominan Keren)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 16
Kanggo Suhu = 0.1 nganti 999.9 ° C Kanggo RH = 0.1 nganti 999.9%
(Default: 50.0)
Wektu Integral
(Zona Pra-dominan Keren)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 17
1 kanggo 3600 Detik
(Default: 100 detik)
Wektu Derivatif
(Zona Pra-dominan Keren)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 18
1 kanggo 600 Detik
(Default: 16 detik)
Band proporsional
(Zona Pre-dominan Panas)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 20
Kanggo Suhu = 0.1 nganti 999.9 ° C Kanggo RH = 0.1 nganti 999.9%
(Default: 50.0)
Wektu Integral
(Zona Pre-dominan Panas)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 21
1 kanggo 3600 Detik
(Default: 100 detik)
Wektu Derivatif
(Zona Pre-dominan Panas)PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 22
1 kanggo 600 Detik
(Default: 16 detik)
Wektu SiklusPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 23 0.5 nganti 100.0 Detik (ing langkah 0.5 detik)
(Default: 10.0 detik)
HisteresisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 24 0.1 nganti 999.9
(Default: 2.0)

PARAMETER SETTING KOMPRESOR: PAGE 17

Paramèter Setelan
(Nilai Default)
Mode Output KompresorPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 25 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 26OFF
ON
OTOMATIS
(Default: Otomatis)
Strategi kompresorPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 27 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 28Bohlam garing SP
Bohlam Kering PV
%RH PV
(Default: Bohlam Kering SP)
Setel-titik watesPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 29 Temp. SP Watesan Low kanggo
Temp. SP Watesan Dhuwur
(Default: 45.0)
Kompresor Set-pointPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 30 0.0 nganti 50.0
(Default: 0.2)
Kompresor HisteresisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 31 0.1 nganti 25.0
(Default: 0.2)
Wektu tundha kompresorPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 32 0.00 nganti 10.00 Min
(ing langkah 5 detik.)
(Default: 0 Sec.)

PARAMETER PENGAWASAN: PAGE 13

Paramèter Setelan
(Nilai Default)
Tune CommandPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 33 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 34(Default: Ora)
Fungsi siyagaPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 35 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 36(Default: Pateni)
Kontrol / Alarm Set-titik Imbuhan
IzinPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 37
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 36(Default: Pateni)
Fungsi Input DigitalPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 38 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 39ora ana
Tingkat banyu
Weker ACK
(Default: Ora ana)
Water Level LogikaPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 40 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 41Bukak minangka Low
Tutup minangka Low
(Default: Open as Low)
Baud RatePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 42 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 43(Default: 9.6)
ParitasPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 44 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 45ora ana
Malah
Aneh
(Default: Malah)
Id Budak PirantiPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 46 1 nganti 127
(Default: 1)
Idin Nulis SerialPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 47 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 34(Default: Ora)

PARAMETER weker: PAGE-10

Paramèter Setelan
(Nilai Default)
Pilih SaluranPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 48 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 49(Default: Suhu)
Weker-1 JinisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 50 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 51ora ana
Proses Kurang
Proses dhuwur
Band nyimpang
Jendela Band
(Default: Ora ana)
Weker-1 HisteresisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 52 0.2 nganti 99.9
(Default: 2.0)
Weker-1 NyandhetPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 53 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 34
Weker-2 JinisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 56 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 57(Default: Ora ana)
Weker-2 HisteresisPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 58 0.2 nganti 99.9
(Default: 2.0)
Weker-2 NyandhetPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 59 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - lambang 34(Default: Ora)
Pilih SaluranPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 60 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 61Temp
Kelembapan
(Default: Suhu)
Tipe Output RecorderPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 62 PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 63(Default: 4 – 20mA)
Perekam LowPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 64 Temp. : 199.9 – 999.9
RH: 0 nganti 100%
(Default: 0.0)
Perekam DhuwurPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 65 Temp. : 199.9 – 999.9
RH: 0 nganti 100%
(Default: 100.0)

TABEL - 1

Pilihan Range (Min. nganti Maks.) Resolusi
3-kawat, RTD Pt100PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 66 -199.9 nganti +600.0 ° C 0.1 °C
0 nganti 20mA DC saikiPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 67 -199.9 kanggo 999.9 Unit 0.1 unit
4 nganti 20mA DC saikiPPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 68
0 nganti 50mV DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 69
0 nganti 200mV DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 70
0 kanggo 1.25 V
DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 71
0 kanggo 5.0 V
DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 72
0 kanggo 10.0 V
DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 73
1 kanggo 5.0 V
DC voltagePPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - icpn 74

LAPORAN PANEL FRONT

Panel ngarepPPI HumiTherm-cS Suhu Lanjut + Kelembapan Programmable Controller - Panel NgarepOperasi tombol

Simbol Kunci Fungsi
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 1 PAGE Pencet kanggo mlebu utawa metu saka mode persiyapan.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 2 TURUN Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 3 UP Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 4 ENTER Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure ing PAGE.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 5 Temp. Set-titik Sunting Pencet kanggo ngetik mode suntingan kanggo Titik Setel Suhu.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 6 %RH
Set-titik Sunting
Pencet kanggo ngetik mode suntingan kanggo %RH Set-point.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 7 Mode siyaga Pencet kanggo mlebu/metu saka mode operasi Siaga.
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 8 View Status Pencet kanggo view informasi proses sing jarang digunakake kaya daya kontrol output lan Wet Bulb SP.

Indikasi kesalahan PV

Pesen Tipe kesalahan PV
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 9 Over-range
(Suhu Bohlam Kering ndhuwur Kisaran Maks.)
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 10 Under-range
(Suhu Bohlam Kering ngisor Kisaran Min.)
PPI HumiTherm-cS Pengontrol Suhu Lanjut + Kelembapan sing Bisa Diprogram - Simbol 11 Mbukak
(Sensor Bohlam Kering (RTD) Rusak / Bukak)

logo PPI101, Diamond Industrial Estate, Navghar,
Jalan Vasai (E), Kab. Palghar – 401 210.
Sales: 8208199048 / 8208141446
Dhukungan: 07498799226 / 08767395333
E: sales@ppiindia.net,
support@ppiindia.net
Januari 2022

Dokumen / Sumber Daya

PPI HumiTherm-cS Suhu Lanjut + Kelembapan Programmable Controller [pdf] Manual pangguna
HumiTherm-cS Pengontrol Kelembaban Suhu Lanjut sing Bisa Diprogram, HumiTherm-cS, Pengontrol Kelembaban Suhu Lanjut sing Bisa Diprogram, Pengontrol sing Bisa Diprogram Kelembaban Suhu, Pengontrol sing Bisa Diprogram Kelembaban, Pengontrol sing Bisa Diprogram, Pengontrol

Referensi

Ninggalake komentar