Manual Instalasi: PAD100-TRTI Two Relay Two Input Module

PEMBERITAHUAN TO INSTALER

Manual iki menehi liwatview lan instruksi instalasi kanggo modul PAD100-TRTI. Modul iki mung kompatibel karo sistem geni sing bisa dialamatake sing nggunakake Protokol Alamat PAD. Kabeh terminal daya winates lan kudu kabel miturut syarat NFPA 70 (NEC) lan NFPA 72 (National Fire Alarm Code). Gagal ngetutake diagram pengkabelan ing kaca ing ngisor iki bakal nyebabake sistem ora bisa digunakake kaya sing dikarepake. Kanggo informasi luwih lengkap, waca pandhuan instalasi panel kontrol. Modul kasebut mung kudu dipasang karo panel kontrol sing kadhaptar. Deleng manual instalasi panel kontrol kanggo operasi sistem sing bener.

Katrangan

PAD100-TRTI nggunakake siji (1) alamat loop SLC nalika ngawasi loro (2) sirkuit Kelas B utawa siji (1) sirkuit Kelas A. PAD100-TRTI uga nyedhiyakake rong (2) kontak relay Formulir C. Modul dipasang ing salah siji kothak 2-geng UL Listed 1-2/2″ utawa kothak kothak 1-1/2″ jero 4″. PAD100-TRTI bisa ngawasi rong (2) sirkuit Kelas B sing kapisah dadi becik kanggo ngawasi aliran banyu sprinkler lan katup tamper ngalih nalika padha dumunung ing jarak sing padha.
PAD100-TRTI kalebu siji LED abang kanggo nuduhake status modul. Ing kondisi normal, LED sumunar nalika piranti lagi polling dening panel kontrol. Nalika input diaktifake, LED bakal sumunar kanthi cepet. Yen kedhip LED wis dipateni liwat piranti lunak pemrograman, ing kondisi normal LED piranti bakal mati. Kabeh kahanan liyane tetep padha.

Nyetel Alamat

Kabeh detektor lan modul protokol PAD mbutuhake alamat sadurunge sambungan menyang daur ulang SLC panel. Alamat saben piranti PAD (yaiku, detektor lan/utawa modul) disetel kanthi ngganti switch dip sing ana ing piranti kasebut. Alamat piranti PAD kasusun saka saklar dip posisi pitu (7) sing digunakake kanggo program saben piranti kanthi alamat saka 1–127.POTTER-PAD100-TRTI-Two-Relay-Two-Input-Module-Instruction-Fig-1

Cathetan: Saben kothak "abu-abu" nuduhake yen saklar dip "Aktif," lan saben kothak "putih" nuduhake "Mati."
mantanamples kapacak ing ngisor iki nggambarake setelan ngalih dip piranti PAD: ex 1stample nuduhake piranti ora ono ngendi kabeh setelan ngalih dip ing standar "Off" posisi, 2. nggambarake piranti PAD ono liwat setelan ngalih dip.POTTER-PAD100-TRTI-Two-Relay-Two-Input-Module-Instruction-Fig-2

Nalika PAD100-TRTI digunakake kanggo ngawasi loro sirkuit Kelas B individu alamat piranti siji diutus; saben input lan relay banjur dikenali minangka sub-titik saka alamat modul. Kanggo example, yen nomer alamat diutus minangka "8", "RLY1" relay bakal dikenali minangka "8.1", "RLY2" relay bakal dikenali minangka "8.2", "B1" input bakal "8.3", lan input "B2" bakal dadi "8.4."
Sadurunge nyambungake piranti menyang loop SLC, tindakake pancegahan ing ngisor iki kanggo nyegah karusakan potensial kanggo SLC utawa piranti.

  • Daya kanggo SLC dibusak.
  • Wiring lapangan ing modul wis diinstal kanthi bener.
  • Wiring lapangan ora duwe sirkuit mbukak utawa cendhak.

Spesifikasi Teknis

Operasional Voltage 24.0V
Max SLC Siyaga Saiki 240 μ A
Max SLC Alarm Saiki 240 μ A
Kontak Relay 2A @30VDC, 0.5A @125VAC
Max Wiring Resistance saka IDC 100 Ω
Max Wiring Kapasitansi saka IDC 1μF
Maks IDC Voltage 2.05 VDC
Max IDC Saiki 120 μ A
Resistor EOL 5.1K
Kisaran Suhu Operasi 32 nganti 120 F (0 nganti 49 C)
Range Kelembapan Operasi 0 nganti 93% (non-kondensasi)
Max ora. saka Modul Per Loop 127 unit
ukuran 4.17 "L x 4.17" W x 1.14" D
Pilihan Pemasangan UL Listed 2-1/2″ jero 2-geng kothak utawa 1-1/2″ jero 4″ kothak kothak
Bobot Pangiriman 0.6 lbs

Wiring Diagram

Diagram wiring ing ngisor iki nggambarake carane kabel modul PAD100-TRTI minangka sirkuit Kelas A lan Kelas B. Kajaba iku, diagram instalasi nuduhake carane nginstal modul nggunakake kothak electrical kompatibel.

POTTER-PAD100-TRTI-Two-Relay-Two-Input-Module-Instruction-Fig-3POTTER-PAD100-TRTI-Two-Relay-Two-Input-Module-Instruction-Fig-4

Cathetan:

  • Kabel output kontak daya diwatesi nalika sumber daya piranti diwatesi. Kabel output kontak ora winates daya nalika sumber daya piranti ora winates daya. Nalika nggunakake non daya wiring winates, iku kudu nggunakake bukaan sulih ing kothak mburi lan kabel routed paling 1/4 inci saka kabel SLC.
  • Gaya kabel SLC ndhukung Kelas A, Kelas B lan Kelas X.
  • Gaya kabel IDC ndhukung Kelas A lan Kelas B.
  • SLC loop wiring (SLC +, SLC-), wiwitan wiring piranti (IN1, IN2) daya winates.
  • Wiring kanggo terminal SLC +, SLC- diawasi.
  • Wiring kanggo terminal (IN1, IN2) diawasi.
  • Modul alamat iki ora ndhukung detektor 2-kabel.
  • Kabeh wiring antarane # 12 (max.) lan # 22 (min.).
  • Preparation Wire - Copot kabeh kabel 1/4 inci saka pinggir kaya sing dituduhake ing kene:POTTER-PAD100-TRTI-Two-Relay-Two-Input-Module-Instruction-Fig-5
    • Mbusak insulasi sing akeh banget bisa nyebabake kesalahan lemah.
    • Stripping sithik banget bisa nyebabake sambungan sing ora apik lan sabanjure sirkuit mbukak.

WARTA
Bisa uga relay internal ing PAD100-TRTI bisa dikirim ing negara non-normal / aktif. Kanggo mesthekake yen relay internal disetel menyang negara normal, sambungake modul menyang loop SLC lan ngreset panel kontrol sadurunge mungkasi kabel menyang output modul.

  • Pandhuan kasebut ora kalebu kabeh rincian utawa variasi ing peralatan sing diterangake, lan uga ora nyedhiyakake saben kontingensi sing bisa ditindakake sajrone instalasi, operasi lan pangopènan.
  • Spesifikasi bisa diganti tanpa kabar sadurunge.
  • Kanggo Bantuan Teknis hubungi Perusahaan Sinyal Listrik Potter ing 866-956-1211.
  • Kinerja nyata adhedhasar aplikasi prodhuk sing tepat dening profesional sing berkualitas.
  • Yen informasi luwih lanjut dikarepake utawa yen ana masalah tartamtu, sing ora cukup kanggo tujuan panuku, masalah kasebut kudu dirujuk menyang distributor ing wilayah sampeyan.

Potter Electric Signal Company, LLC
St Louis, MO
Telpon: 800-325-3936
www.pottersignal.com
firealarmresources.com

Dokumen / Sumber Daya

POTTER PAD100-TRTI Two Relay Two Input Module [pdf] Instruksi Manual
PAD100-TRTI Loro Relay Loro Modul Input, PAD100-TRTI, Loro Relay Loro Modul Input, Relay Loro Modul Input, Loro Modul Input, Modul Input, Modul
POTTER PAD100-TRTI Two Relay Two Input Module [pdf] Manual Pamilik
PAD100-TRTI Loro Relay Loro Modul Input, PAD100-TRTI, Loro Relay Loro Modul Input, Loro Modul Input

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *