ICON-logo

KONTROL PROSES ICON TVF Series Flow Display Controller

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-prodjuct

Waca manual pangguna kanthi teliti sadurunge miwiti nggunakake unit. Produser nduweni hak kanggo ngleksanakake owah-owahan tanpa kabar sadurunge.

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig 40Katrangan Simbol

Simbol iki nuduhake pedoman utamane penting babagan instalasi lan operasi piranti. Ora netepi pedoman sing dituduhake simbol iki bisa nyebabake kacilakan, karusakan utawa karusakan peralatan.

Syarat dhasar

Safety pangguna

  • Aja nggunakake unit ing wilayah sing kaancam kejut gedhe banget, geter, bledug, kelembapan, gas korosif lan lenga.
  • Aja nggunakake unit ing wilayah sing ana risiko bledosan.
  • Aja nggunakake unit ing wilayah kanthi variasi suhu sing signifikan, paparan kondensasi utawa es.
  • Pabrikan ora tanggung jawab kanggo karusakan apa wae sing disebabake dening instalasi sing ora cocog, ora njaga kahanan lingkungan sing cocog lan nggunakake unit kasebut bertentangan karo tugase.
  • Yen ing kasus kerusakan unit ana risiko ancaman serius kanggo safety wong utawa properti tambahan, sistem lan solusi independen kanggo nyegah ancaman kasebut kudu digunakake.
  • Unit nggunakake vol mbebayanitage sing bisa nyebabake kacilakan sing bisa nyebabake. Unit kasebut kudu dipateni lan dicopot saka sumber daya sadurunge miwiti instalasi pemecahan masalah (ing kasus malfunction).
  • Aja nyoba mbongkar, ndandani utawa ngowahi unit dhewe. Unit kasebut ora duwe bagean sing bisa digunakake kanggo pangguna.
  • Unit sing rusak kudu dicopot lan diajukake kanggo ndandani ing pusat layanan sing sah

Spesifikasi

Umum
Tampilan LED | 6 Angka | 13mm Dhuwur | abang | Padhang luwes
Nilai sing ditampilake 0 ~ 999999
Transmisi RS485 1200…115200 bit/s, 8N1 / 8N2
Material omah ABS | Polikarbonat
Kelas Proteksi NEMA 4X | IP67
Sinyal Input | Pasokan
Standar Saiki: 4-20mA | 0-20mA | 0-5V* | 0-10V *
Voltage 85 – 260V AC/DC | 16 – 35V AC, 19 – 50V DC*
Sinyal Output | Pasokan
Standar 2 x Relay (5A) | 1 x Relay (5A) + 4-20mA
Komunikasi RS485
Voltage 24VDC
Output saiki pasif * 4-20mA | (Rentang Operasi Maks. 2.8 – 24mA)
Kinerja
Akurasi 0.1% @ 25°C Siji Digit
Suhu
Suhu operasi -40 – 158°F | -40 – 70°C

Deskripsi Panel DepanICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (1)

Fungsi Push ButtonsICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (2)

ukuranICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (3)

Wiring DiagramICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (4)IKON-PROSES-KONTROL-TVF-Series-Flow-Display-Controller-fig (5).....

INSTALASI KENDIRI

  • Lebokake obeng lan push mekanisme ngunci kawat mbukak
  • Pasang kawat
  • Copot obeng

Amarga kemungkinan gangguan sing signifikan ing instalasi industri, langkah-langkah sing cocog kanggo njamin operasi unit sing bener kudu ditrapake.
Unit kasebut ora dilengkapi sekring internal utawa pemutus sirkuit sumber daya. Mulane, sekring potong wektu tundha eksternal kanthi nilai arus nominal cilik kudu digunakake (bipolar sing disaranake, maksimal 2A) lan pemutus sirkuit sumber daya sing ana ing cedhak unit.

Sambungan

Power Supply & Relay SambunganICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (6)

Kontak output relay ora dilengkapi karo suppressors spark. Nalika nggunakake output relay kanggo ngoper beban induktif (koil, kontaktor, relay daya, elektromagnet, motor lan sapiturute) kudu nggunakake sirkuit supresi tambahan (biasane kapasitor 47nF / min. 250VAC ing seri karo resistor 100R / 5W), disambungake. ing podo karo kanggo relay terminal utawa (luwih apik) langsung ing mbukak.

Sambungan Sirkuit SuppressionICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (7)

Sambungan Output Tipe OCICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (8)

Sambungan Output Saiki Nggunakake Sumber Daya InternalICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (9)

Sambungan Output Saiki Nggunakake Sumber Daya EksternalICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (10)

Sambungan Flow Meter (Tipe Relay)

TKM Seri: 4-20mA Output
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
11 kuning mA +
12 abu-abu mA-

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (11)

Seri TKS: Output Pulsa
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 ireng Pulsa NPN
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (12)

TKW Series: Pulse Output
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 ireng Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (13)

TKW Series: 4-20mA Output
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
11 ireng mA +
12 Putih mA-

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig 41

Seri TKP: Output Pulsa
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 ireng Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (14)

Seri TIW: Output Pulsa
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 Putih Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (15)

TIM | Seri TIP: Output Pulse
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 ireng Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (16)

Seri TIM: Output 4-20mA
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
11 kuning mA +
12 abu-abu mA-

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (17)

UF 1000 | 4000 | 5000 - Output Pulsa
GPM/Pulse = faktor K
Terminal TVF Pin Katrangan
8 1 + VDC
10 2 Pulsa
7 3 -VDC
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (18)

UF 1000 | 4000 | 5000 - 4-20mA Output
Terminal TVF Pin Katrangan
8 1 + VDC
11 2 +mA
7 3 -VDC
Langsung 12 & 7

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (19)

ProPulse (Flying Lead) - Output Pulse
GPM/Pulse = faktor K
Terminal TVF Warna Wire Katrangan
7 tameng -VDC
8 abang + VDC
10 Biru Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (20)

ProPulse®2 - Output Pulsa
Terminal TVF Warna Wire Katrangan
7 Biru -VDC
8 coklat + VDC
10 ireng Pulsa
Langsung 13 & 8

ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (21)

Programming K FactorICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (22) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (23)

Pemrograman RelayICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (24) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (25) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (26) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (27) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (28)

Batching PemrogramanICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (29) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (30) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (31) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (32) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (33) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (34)

Ngreset BatchICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (35) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (36) ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (37)

Ngreset TotalizerICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (38)ICON-PROCESS-CONTROLS-TVF-Series-Flow-Display-Controller-fig (39)

Warranty, Bali lan Watesan

Garansi

Icon Process Controls Ltd njamin marang panuku asli produk kasebut yen produk kasebut bakal bebas saka cacat ing \material lan pengerjaan ing panggunaan lan layanan normal miturut pandhuan sing diwenehake dening Icon Process Controls Ltd sajrone setaun wiwit tanggal sale produk kuwi. Kewajiban Icon Process Controls Ltd miturut garansi iki mung diwatesi kanggo ndandani utawa ngganti, ing pilihan Icon Process Controls Ltd, produk utawa komponen, sing ditemtokake dening pamriksaan Icon Process Controls Ltd kanthi kepuasan materi utawa karya ing njero. wektu babar pisan. Icon Process Controls Ltd kudu diwenehi kabar miturut pandhuan ing ngisor iki babagan pratelan ing garansi iki sajrone telung puluh (30) dina saka kekurangan produk sing diklaim. Sembarang produk sing didandani miturut garansi iki bakal dijamin mung kanggo sisa periode garansi asli. Produk apa wae sing disedhiyakake minangka panggantos miturut garansi iki bakal dijamin setaun wiwit tanggal panggantos.

wangsul

Produk ora bisa bali menyang Icon Process Controls Ltd tanpa wewenang sadurunge. Kanggo mbalekake produk sing dianggep rusak, bukak www.iconprocon.com, lan kirim formulir panjaluk pengembalian pelanggan (MRA) lan tindakake pandhuane. Kabeh produk garansi lan non-garansi bali menyang Icon Process Controls Ltd kudu dikirim kanthi prabayar lan diasuransiake. Ikon Proses Kontrol Ltd ora bakal tanggung jawab kanggo produk sing ilang utawa rusak nalika dikirim.

Watesan

Garansi iki ora ditrapake kanggo produk sing: 1) ngluwihi periode babar pisan utawa produk sing panuku asli ora ngetutake prosedur babar pisan sing kasebut ing ndhuwur; 2) wis ngalami karusakan listrik, mekanik utawa kimia amarga panggunaan sing ora bener, ora sengaja utawa ora sengaja; 3) wis diowahi utawa diowahi; 4) sapa wae kajaba personel layanan sing sah dening Icon Process Controls Ltd wis nyoba ndandani; 5) wis nandhang kacilakan utawa bencana alam; utawa 6) rusak sajrone kiriman bali menyang Icon Process Controls Ltd duwe hak kanggo mbatalake garansi iki kanthi sepihak lan mbuwang produk apa wae sing bali menyang Icon Process Controls Ltd ing ngendi: 1) ana bukti yen ana bahan sing bisa mbebayani ing produk kasebut; utawa 2) prodhuk kasebut tetep ora dituntut ing Icon Process Controls Ltd luwih saka 30 dina sawise Ikon Proses Controls Ltd wis njaluk disposisi. Garansi iki ngemot garansi ekspres tunggal sing digawe dening Icon Process Controls Ltd sing ana gandhengane karo produke. ALL JAMINAN sing diwenehake, kalebu TANPA watesan, JAMINAN DAGANG lan KESESUAIAN UNTUK TUJUAN KHUSUS, DIPENGARUHI. Pangobatan kanggo ndandani utawa ngganti kaya kasebut ing ndhuwur minangka obat eksklusif kanggo nglanggar garansi iki. Ora ana acara Ikon Proses Controls Ltd TANGGUNG JAWAB ATAS KERUSAKAN INSIDENTAL UTAWA KONSEQUENTIAL KANGGO KANGGO PRIBADI UTAWA NYATA UTAWA KANGGO LUKA SING ANYAR. JAMINAN INI MANGGO PANGAJIAN FLASH, LENGKAP lan EKSKLUSIF SYARAT-SYARAT JAMINAN lan ora ana wong sing nduweni wewenang kanggo nggawe JAMINAN LAIN UTAWA REPRESENTASI atas jenenge Icon Process Controls Ltd. Jaminan iki bakal diinterpretasikake miturut hukum provinsi Ontario, Kanada. Yen bagean saka jaminan iki dianggep ora sah utawa ora bisa ditindakake kanthi alesan apa wae, panemuan kasebut ora bakal mbatalake pranata liyane saka garansi iki.

Kanggo dokumentasi produk tambahan lan dhukungan teknis

Dokumen / Sumber Daya

KONTROL PROSES ICON TVF Series Flow Display Controller [pdf] Manual pangguna
Seri TVF, Pengontrol Tampilan Aliran Seri TVF, Pengontrol Tampilan Aliran, Pengontrol Tampilan, Pengontrol

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *