Power Control Prosesor Mk2 Network mandap Kit
Informasi produk
Prosesor Kontrol Daya Mk2 (PCP-Mk2) minangka komponen sing digunakake ing Feed Echo Relay Panel Mains lan Elaho Relay Panel Mains Feed (ERP Mains Feed), Echo Relay Panel Feedthrough lan Elaho Relay Panel Feedthrough (ERP Feedthrough), lan sistem Sensor IQ. . Kit terminasi jaringan PCP-Mk2 kalebu konektor Cat5, kothak Cat5 sing dipasang ing permukaan, tape dobel, lan kabel patch Cat5. Kit kasedhiya ing rong varian, 7123K1129 ERP-FT lan 7131K1029 Sensor IQPCP-Mk2 Network Termination Kits, lan 7123K1029 ERP PCP-Mk2 Network Termination Kit. Prodhuk iki dirancang kanggo mbantu pangguna kabel konektor lan ngumpulake menyang panel kanthi efisien.
Panggunaan produk
WARNING: RISIKO KEMATIAN KERET ELEKTRIK!
Sadurunge nggarap panel, mesthekake yen kabeh daya kanggo panel wis pedhot kanggo nyegah ciloko serius utawa pati.
Piranti sing dibutuhake
Pangguna mbutuhake ETC Retrofit Guide, Power Control Processor Mk2 Network Termination Kit, lan alat instalasi Cat5 standar.
Kabel Konektor
Tindakake langkah iki kanggo nyambungake konektor permukaan-mount Kategori 5:
- Ninggalake dawane kira-kira 25 cm (10 in) ing panel kanggo nyambungake lan kendur kanggo kabutuhan layanan ing mangsa ngarep.
- Tindakake tata cara instalasi Cat5 standar kanggo mbusak mburi jaket kabel lan mbukak konduktor.
- Copot konduktor lan baris miturut tandha kode warna T568B. Lebokake konduktor menyang tutup konektor. Jaket kabel kudu cedhak karo pinggiran konektor kanthi konduktor sing katon sithik. Yen ora, Cut kabel squarely lan miwiti maneh.
- Yen ana konduktor ngluwihi pinggiran tutup konektor, potong keluwihan kasebut supaya ujung konduktor disiram karo pinggir tutup konektor.
- Pencet tutup kanthi kenceng ing dasar konektor nganti rong potongan sworo seru. Gunakake tang sambungan slip kanggo ngetrapake tekanan kanthi merata ing tutup lan kanggo ngamanake sambungan, nanging priksa manawa plastik ora pecah nalika ngetrapake tekanan.
Masang Konektor menyang Box lan Assembling
Tindakake langkah iki kanggo masang konektor menyang kothak lan ngumpul:
- Lebokake pinggiran ngarep konektor menyang kothak soyo tambah supaya slot ing pojok ngarep konektor selaras karo tab ing bagean ngisor kothak.
- Push mudhun ing mburi konektor kanggo sworo seru menyang kothak.
- Ing mburi tutup duwe potongan cilik U-shaped. Copot cutout iki supaya kabel bisa liwat tanpa pinched. Rute kabel liwat guide kothak minangka ditampilake.
- Selarasake tutup karo bagean ngisor lan jepret rong potong bebarengan.
Nginstal Konektor ing Panel
Gunakake tape pindho sisi sing kasedhiya ing kit retrofit kanggo masang ngisor kothak lumahing-mount kanggo panel Panjenengan. Deleng ilustrasi ing ngisor iki kanggo referensi:

Sawise masang kothak lumahing-gunung menyang panel, produk wis siyap kanggo nggunakake.
Swaraview
- Prosesor Kontrol Daya Mk2 (PCP-Mk2) digunakake ing Feed Echo Relay Panel Mains Feed lan Elaho Relay Panel Mains Feed (ERP Mains Feed), Echo Relay Panel Feedthrough lan Elaho Relay Panel Feedthrough (ERP Feedthrough), lan sistem Sensor IQ.
- WARNING: RISIKO KEMATIAN KERET ELEKTRIK! Gagal medhot kabeh daya menyang panel sadurunge digunakake ing njero bisa nyebabake ciloko serius utawa pati.
- De-energize feed utama menyang panel lan tindakake Lockout cocok /Tagprosedur metu minangka mandat dening NFPA 70E. Wigati dimangerteni manawa peralatan listrik kayata panel relay bisa nyebabake bebaya lampu kilat busur yen ora dilayani kanthi bener. Iki amarga jumlah arus hubung singkat sing kasedhiya ing pasokan listrik kanggo peralatan iki. Karya apa wae kudu tundhuk karo Praktek Kerja Aman OSHA.
Kalebu ing Kit
7123K1129 ERP-FT lan 7131K1029 Sensor Kit Terminasi Jaringan IQPCP-Mk2
Katrangan | Nomer Part ETC | Jumlah |
Konektor Cat5 Kab | N2026 | 1 |
kothak Cat5 lumahing-mount | N2025 | 1 |
Pita dobel, 1.5 in | I342 | 1 |
Kabel patch Cat1 5 ft | N4036 | 1 |
7123K1029 ERP PCP-Mk2 Kit Mandap Jaringan
Katrangan | Nomer Part ETC | Jumlah |
Konektor Cat5 Kab | N2026 | 1 |
kothak Cat5 lumahing-mount | N2025 | 1 |
Pita dobel, 1.5 in | I342 | 1 |
Pemasangan adhesive pengikat kabel | HW741 | 2 |
Pengikat kabel | HW701 | 2 |
Kabel patch Cat4 5 ft | N4009 | 1 |
Piranti sing dibutuhake
- Obeng Phillips
- Slip joint tang
- Alat sheathing utawa cutter kanggo jaket kabel Cat5
Kabel Konektor
Konektor permukaan-mount Kategori 5 sing disedhiyakake ing kit iki kalebu rong potongan: unit dasar lan tutup. Tutup kasebut nduweni tandha warna ing salah sawijining ujung kanggo nunjukake ing ngendi kanggo nglebokake saben kabel kode warna kabel. Tindakake skema kabel T568B, kaya sing digambarake ing stiker tutup, kanggo kompatibilitas karo konvensi kabel jaringan ETC.
- Ninggalake dawane kira-kira 25 cm (10 in) ing panel kanggo nyambungake lan kendur kanggo kabutuhan layanan ing mangsa ngarep.
- Tindakake prosedur instalasi Cat5 standar kanggo mbusak ujung jaket kabel lan mbukak konduktor:
- Copot sekitar 13 mm (1/2 in) saka mburi jaket kabel njaba nggunakake alat sheathing utawa cutter, nggawe manawa ora ngrusak insulasi saka konduktor utama. Yen salah siji utawa luwih saka konduktor rusak sak proses iki, Cut kabel mati squares lan miwiti maneh.
- Copot konduktor lan baris miturut tandha kode warna T568B. Lebokake konduktor menyang tutup konektor. Jaket kabel kudu cedhak karo pinggiran konektor kanthi konduktor sing katon sithik. Yen ora, Cut kabel squarely lan miwiti maneh.
- Yen ana konduktor ngluwihi pinggiran tutup konektor, potong keluwihan kasebut supaya ujung konduktor disiram karo pinggir tutup konektor.
- Pencet tutup kanthi kenceng ing dasar konektor nganti rong potongan sworo seru. Gunakake tang sambungan slip kanggo ngetrapake tekanan kanthi merata ing tutup lan kanggo ngamanake sambungan, nanging priksa manawa plastik ora pecah nalika ngetrapake tekanan.
Instal Konektor ing Panel
Gunakake tape pindho sisi sing kasedhiya ing kit retrofit kanggo masang ngisor kothak lumahing-mount kanggo panel Panjenengan. Waca ilustrasi ing ngisor iki. Waca ilustrasi ing ngisor iki.
Sambungake Kabel Patch
ERP Feedthrough utawa Sensor IQ
Sambungake kabel patch 1 ft (N4036) saka konektor permukaan-gunung menyang mburi antarmuka pangguna.
Cathetan: IQ Sensor sing ditampilake ing ndhuwur dipasang ing orientasi feed ndhuwur
Feed utama ERP
Top-Feed
- Rute kabel patch jaringan 4 ft (N4009) liwat bukaan kabel pita ing ngisor pager antarmuka pangguna, ing mburi panel pemasangan kertu relay menyang kothak surfacemount.
- Kit kalebu dasi kabel lan dasi kabel adhesive gunung kanggo sugih kabel patch, minangka needed.
- Sambungake kabel patch menyang kothak lumahing-mount.
- Sambungake kabel patch menyang mburi antarmuka panganggo.
Feed ngisor
- Rute kabel patch jaringan 4 ft (N4009) saka kothak lumahing gunung, ing mburi panel pemasangan kertu relay, lan liwat bukaan kabel pita ing ngisor pager antarmuka pangguna.
- Kit kalebu dasi kabel lan dasi kabel adhesive gunung kanggo sugih kabel patch, minangka needed.
- Sambungake kabel patch menyang mburi antarmuka panganggo.
- Sambungake kabel patch menyang kothak lumahing-mount.
Dokumen / Sumber Daya
![]() |
Prosesor Kontrol Daya ECHO Mk2 Kit Terminasi Jaringan [pdf] Pandhuan pangguna Prosesor Kontrol Daya Mk2, Kit Terminasi Jaringan, Prosesor Kontrol Daya Mk2 Kit Terminasi Jaringan, Kit Terminasi, PCP-Mk2 |