Platform Sensor Modular E Plus E Sigma 05
Spesifikasi
- Jeneng produk: Sigma 05 – Hub Sensor / Platform Sensor Modular
- Antarmuka: RS485
- Protokol: Modbus RTU
- Jumlah maksimum probe: 3
- Pasokan Voltage Range: 15 – 30 V DC
Pandhuan Panggunaan Produk
Operasi / Setup Plug-and-Play
Sigma 05 dirancang kanggo nggarap probe plug-and-play E + E. Kanthi gawan, fungsi panemuan otomatis diaktifake.
Tindakake langkah iki kanggo persiyapan:
- Mateni Sigma 05 sadurunge nyambungake utawa medhot probe.
- Sigma 05 bakal kanthi otomatis ngenali lan ngatur probe sing disambungake miturut tabel sing wis ditemtokake.
- Penugasan ukuran lan skala output ditindakake kanthi otomatis adhedhasar probe sing disambungake.
Operasi Manual / Setup
- Sambungake Sigma 05 menyang komputer pribadi sing nganggo PCS10 Product Configuration Software.
- Pateni fungsi panemuan otomatis ing piranti lunak.
- Nemtokake ukuran kanggo output lan ngatur skala output yen perlu.
Voltage Pasokan lan Output
- Priksa manawa instalasi lan kabel sing bener kanggo nyegah overheating.
- Tindakake diagram kabel sing kasedhiya kanggo versi produk sampeyan.
- Sumber voltagkisaran e antara 15 – 30 V DC.
Modbus Setup
Setelan pabrik kanggo komunikasi Modbus kaya ing ngisor iki.
- Tingkat baud: 9 600
- Bit data: 8
- Paritas: Malah
- Stop bit: 1
- Alamat Modbus: Ora disetel kanggo Sigma 05
Persetujuan
Sigma 05 duwe persetujuan jinis maritim DNV. Deleng Manual pangguna kanggo informasi rinci.
PAMBUKA
Elinga
Temokake dokumen iki lan informasi produk liyane babagan kita websitus ing www.epluse.com/sigma05.
Informasi Umum
- Sigma 05 minangka piranti host (Modbus master) nganti telung piranti pangukuran / pangukuran sensing E + E kanthi antarmuka RS485 lan protokol Modbus RTU.
- Pandhuan Cepet iki fokus ing fungsi Sigma 05 kanthi probe plug-and-play E + E. Mangga priksa manehview manual pangguna Sigma 05 ing www.epluse.com/sigma05 kanggo persiyapan manual lan fitur Sigma 05 liyane.
Persiyapan Operasi Plug lan Play
- Kanthi fungsi panemuan otomatis sing diaktifake (setelan standar), Sigma 05 kanthi otomatis ngenali probe plug-and-play E + E lan kombinasi kasebut miturut tabel ing ngisor iki, ndeleng "Kombinasi Probe lan Penemuan Otomatis".
- Salajengipun, penugasan ukuran menyang output lan tampilan, uga skala output ditindakake kanthi otomatis miturut tabel.
- Persiyapan iki bisa diganti sabanjure dening pangguna kaya sing dibutuhake, deleng "Operasi / Persiyapan Manual" ing ngisor iki.
Elinga
Sigma 05 kudu dipateni nalika nyambungake utawa medhot probe
Persiyapan Operasi Manual
- Kanggo persiyapan manual, sambungake Sigma 05 menyang komputer pribadi sing nganggo Piranti Lunak Konfigurasi Produk PCS10, download gratis saka www.epluse.com/pcs10.
- Pateni fungsi panemuan otomatis lan terusake nemtokake ukuran menyang output lan tampilan uga skala output. Waca manual pangguna ing www.epluse.com/sigma05.
Fungsi nomer pin
1 | Pasokan voltage*) |
2 | RS485 B (D-) |
3 | GND |
4 | RS485 A (D+) |
- Sumber voltage ing konektor probe tansah padha karo sumber voltage ditrapake kanggo Sigma 05.
- penting: Pilih Sigma 05 supply voltage (ing sawetara 15 - 30 V DC) kanggo cocog karo syarat sumber probe.
Voltage Pasokan lan Output
- WARNING Instalasi, kabel utawa sumber daya sing salah bisa nyebabake overheating lan mulane ciloko pribadi utawa karusakan properti.
- Kanggo kabel sing bener saka piranti, tansah mirsani diagram wiring presented kanggo versi produk digunakake.
- Produsèn ora bisa tanggung jawab kanggo ciloko pribadi utawa karusakan kanggo properti minangka asil saka salah nangani, instalasi, wiring, sumber daya lan pangopènan piranti.
Modbus Setup
Setelan pabrik | Nilai sing bisa dipilih pangguna (liwat PCS10) | |
Baud rate | 9 600 | 9 600, 19 200, 38 400, 57 600, 76 800, 115 200 |
Bit data | 8 | 8 |
Paritas | Malah | Ora ana, ganjil, malah |
Mungkasi bit | 1 | 1, 2 |
Alamat modbus | Sigma 05 ora duwe alamat Modbus |
- Setelan sing disaranake kanggo macem-macem piranti ing jaringan Modbus RTU yaiku 9600, 8, Even, 1.
- Sigma 05 nggambarake 1 unit beban ing jaringan Modbus.
Persetujuan
DNV (Det Norske Veritas) persetujuan jinis maritim.
- Kanggo ruang lingkup persetujuan, waca Manual pangguna, bab 9.4 Persetujuan Tipe DNV.
Kombinasi Probe lan Penemuan Otomatis
Output Analog 1 | Output Analog 2 | Tampilan baris 1 | Tampilan baris 2 | Tampilan baris 3 | |||||||||
Probes | Unit | Skala SI | Skala AS | Unit | Skala SI | Skala AS | SI | US | SI | US | SI | US | |
1 EE072 | RH | 0…100% | 0…100% | T | -40… 80 ° C | -40…176 °F | RH[%] | RH[%] | T[°C] | T[°F] | |||
2 EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
3 EE872-M13 | CO2 | Range probe | Range probe | RH | 0…100% | 0…100% | CO2[ppm] | CO2[ppm] | RH[%] | RH[%] | T[°C] | T[°F] | |
4 EE872-M10 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | ||||||||
5 EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | ||||||||
6 EE680 | vn | Range probe | Range probe | T | 0… 50 ° C | 32…122 °F | vn [m/s] | vn [ft/min] | T[°C] | T[°F] | |||
7 HA010406 | RH | 0…100% | 0…100% | T | -40… 180 ° C | -40…356 °F | RH[%] | RH[%] | T[°C] | T[°F] | |||
8 | EE072 | RH | 0…100% | 0…100% | RH[%] | RH[%] | |||||||
EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
9 | EE872-M13 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | |||||||
EE072 | RH | 0…100% | 0…100% | RH[%] | RH[%] | T[°C] | T[°F] | ||||||
10 | EE872-M10 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | |||||||
EE072 | RH | 0…100% | 0…100% | RH[%] | RH[%] | T[°C] | T[°F] | ||||||
11 | EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | |||||||
EE072 | RH | 0…100% | 0…100% | RH[%] | RH[%] | T[°C] | T[°F] | ||||||
12 |
EE680 | v | Range probe | Range probe | vn [m/s] | vn [ft/min] | |||||||
EE072 | RH | 0…100% | 0…100% | RH[%] | RH[%] | T[°C] | T[°F] | ||||||
13 |
EE872-M13 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | RH[%] | RH[%] | |||||
EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
14 |
EE872-M10 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | |||||||
EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
15 |
EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | |||||||
EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
16 |
EE680 | vn | Range probe | Range probe | vn [m/s] | vn [ft/min] | |||||||
EE074 | T | -40… 80 ° C | -40…176 °F | T[°C] | T[°F] | ||||||||
17 |
EE872-M13 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | T[°C] | T[°F] | |||||
EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | ||||||||
18 |
EE872-M13 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | T[°C] | T[°F] | |||||
EE680 | vn | Range probe | Range probe | vn [m/s] | vn [ft/min] | ||||||||
19 |
EE872-M10 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | |||||||
EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | ||||||||
20 |
EE872-M10 | CO2 | Range probe | Range probe | CO2[ppm] | CO2[ppm] | |||||||
EE680 | vn | Range probe | Range probe | vn [m/s] | vn [ft/min] | T[°C] | T[°F] | ||||||
21 |
EE680 | vn | Range probe | Range probe | vn [m/s] | vn [ft/min] | T[°C] | T[°F] | |||||
EE671 | v | Range probe | Range probe | v[m/s] | v[ft/min] | ||||||||
22 HTP501 | RH | 0…100% | 0…100% | T | -40… 120 ° C | -40…248 °F | RH[%] | RH[%] | T[°C] | T[°F] | |||
23 |
HTP501 | RH | 0…100% | 0…100% | RH[%] | RH[%] | T[°C] | T[°F] | |||||
EE074 | T | -40… 120 ° C | -40…248 °F | T[°C] | T[°F] | ||||||||
24 MOP301 | aw | 0…1 | 0…1 | T | -40… 120 ° C | -40…248 °F | aw[-] | aw[-] | T[°C] | T[°F] | |||
25 |
MOP301 | aw | 0…1 | 0…1 | aw[-] | aw[-] | T[°C] | T[°F] | |||||
EE074 | T | -40… 120 ° C | -40…248 °F | T[°C] | T[°F] |
- E+E Elektronik Ges.mbH
- Langwiesen 7
- 4209 Engerwitzdorf
- Austria
- T + 4372356050
- F + 4372356058
- info@epluse.com
- www.epluse.com
- QG_Sigma_05
- Versi v2.0
- 06-2024
- Kabeh hak dilindhungi undhang-undhang
- 195001
FAQ
- P: Bisa nyambung luwih saka telung probe menyang Sigma 05?
- A: Ora, Sigma 05 ndhukung maksimal telung probe.
- P: Apa sing kedadeyan yen aku nggunakake sumber voltage njaba kisaran dianjurake?
- A: Nggunakake sumber voltage ing njaba kisaran 15 – 30 V DC bisa nyebabake operasi utawa karusakan piranti sing salah.
- P: Kepiye carane ngganti setelan Modbus?
- A: Gunakake Piranti Lunak Konfigurasi Produk PCS10 kanggo milih nilai sing bisa dipilih pangguna kanggo setelan Modbus.
Dokumen / Sumber Daya
![]() |