MW PW M -90 seri Konstan Voltage PWM Output LED Driver
Fitur
- Pancet Voltage output gaya PWM
- Aplikasi lampu darurat kasedhiya miturut IEC61347-2-13
- Dibangun ing fungsi PFC aktif lan desain kelas II
- Unit daya kelas 2 (kajaba PWM-90-12)
- Ora ana konsumsi daya mbukak <0.5W
- Kanthi encapsulated karo tingkat IP67
- Fungsi: 3 ing 1 dimming (dim-kanggo-mati); DAL/DALI-2
- Tingkat dimming minimal 0.2% kanggo jinis DALI
- Umur khas> 50000 jam lan garansi 5 taun
Aplikasi
- Lampu strip LED
- Lampu LED njero ruangan
- Lampu hias LED
- Lampu arsitektur LED
- Lampu industri
KODE GTIN
Panelusuran MW: http:/www.meanwell.com/serviceGTIN.aspx
Katrangan
PWM-90 seri punika 90W LED AC/DC driver LED nampilaken vol konstantage mode karo output gaya PWM, kang bisa kanggo njaga homogeneity padhange nalika nyopir kabeh jinis LED strips.PWM-90 makaryakke saka 90 ~ 305VAC lan nawakake model karo dirating vol beda.tage kiro-kiro antarane 12V lan 48V. Thanks kanggo efisiensi dhuwur nganti 90.5%, kanthi desain tanpa kipas, kabeh seri bisa digunakake kanggo suhu kasus -40C + 85C ing konveksi udara gratis. Seri kabeh dirating karo tingkat pangayoman ingress IP67 lan cocok kanggo bisa garing, damp utawa panggonan udan. PWM-90 dilengkapi fungsi dimming sing beda-beda siklus tugas saka output, nyediakake keluwesan gedhe kanggo aplikasi ngudani LED.
Encoding Model
SPESIFIKASI
MODEL | PWM-90-12 | PWM-90-24 | PWM-90-36 | PWM-90-48 | |
OUTPUT |
DC VOLTAGE | 12V | 24V | 36V | 48V |
RATED SAIKI | 7.5A | 3.75A | 2.5A | 1.88A | |
DAYA RATED | 90W | 90W | 90W | 90.24W | |
DIMMING RANGE | 0 ~ 100% | ||||
PWM FREKUENSI (Jenis.) | 1.47kHz kanggo Blank/Tipe DA, 2.5kHz kanggo Tipe DA2 | ||||
SETUP, Munggah WAKTU Cathetan.2
Cathetan.9 |
500ms, 80ms / 115VAC utawa 230VAC | ||||
WAKTU TAHAN (Typ.) | 16ms / 115VAC utawa 230VAC | ||||
INPUT |
VOLTAGE RANGKA Cathetan.3 | 90 ~ 305VAC 127 ~ 431VDC
(Waca bagean "KARAKTERISTIK STATIS") |
|||
RANGKA FREKUENSI | 47 ~ 63Hz | ||||
FAKTOR DAYA (Jenis.) | PF> 0.98 / 115VAC, PF> 0.96 / 230VAC, PF> 0.92 / 277VAC @ beban kebak
(Waca bagean "POWER FACTOR (PF) KARAKTERISTIK") |
||||
TOTAL HARMONIK DISTORSI | THD< 20% (@load≧60%/115VAC, 230VAC; @load≧75%/277VAC)
(Mangga waca bagean "TOTAL HARMONIC DISTORTION") |
||||
EFISIENSI (Typ.) | 88% | 90.5% | 90.5% | 90.5% | |
AC ARUS (Typ.) | 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC | ||||
INRUSH CURRENT (Jinis.) | COLD START 60A(twidth=550 μs diukur ing 50% Ipeak) ing 230VAC; Miturut NEMA 410 | ||||
MAX. NO. saka PSU ing 16A CIRCUIT BREAKER | 3 unit (pemutus sirkuit tipe B) / 6 unit (pemutus sirkuit tipe C) ing 230VAC | ||||
KEBOCORAN SAIKI | <0.25mA / 277VAC | ||||
| <0.5W | ||||
pangayoman |
kakehan | 108 ~ 130% daya output dirating | |||
Mode Hiccup, pulih kanthi otomatis sawise kondisi fault dibusak | |||||
CIRCUIT PENDEK | Mati o/p voltage, urip maneh kanggo mbalekake (kajaba kanggo DA2-jinis)
Mode Hiccup, pulih kanthi otomatis sawise kondisi fault dibusak (mung kanggo DA2-jinis) |
||||
Liwat VOLTAGE |
15 ~ 17V | 28 ~ 34V | 41 ~ 46V | 54 ~ 60V | |
Mati o/p voltage, aktif maneh supaya pulih | |||||
SUHU | Mati o/p voltage, aktif maneh supaya pulih | ||||
LINGKUNGAN |
KERJA TEMP. | Tcase=-40 ~ +85 ℃ (Waca bagean "BEBAN OUTPUT vs SUHU") | |||
MAX TEMP KASUS. | Tcase = + 85 | ||||
AMBES KERJA | 20 ~ 95% RH ora kondensasi | ||||
STORAGE TEMP., Asor | -40 ~ + 80 ℃, 10 ~ 95% RH | ||||
TEMP COEFFICIENT | ± 0.03% / ℃ (0 ~ 50 ℃) | ||||
GETERAN | 10 ~ 500Hz, 5G 12min./1siklus, wektu kanggo 72min. saben sumbu X, Y, Z | ||||
KESELAMATAN & EMC |
STANDAR KESELAMATAN Cathetan.5 |
UL8750 (kajaba DA-Type), CSA C22.2 No.. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independen, BS EN/EN62384, IP67, BIS IS15885 (mung kanggo 12,24,48 Tipe Kosong), EAC TP TC 004, GB19510.1, GB19510.14. XNUMX disetujoni;
Desain deleng BS EN/EN60335-1; Miturut BS EN/EN61347-2-13 lampiran J cocok kanggo instalasi darurat |
|||
DALI STANDAR | IEC62386-101, 102, 207,251 mung kanggo Tipe DA/DA2, Tipe piranti 6(DT6) | ||||
Tahan VOLTAGE | I / PO / P: 3.75KVAC; I/P-DA: 1.5KVAC; O/P-DA: 1.5KVAC | ||||
RESISTANCE Isolasi | I/PO/P: 100M Ohm / 500VDC / 25 ℃ / 70% RH | ||||
EMISI EMC Cathetan.6 | Kepatuhan BS EN / EN55015, BS EN / EN61000-3-2 Kelas C (@ mbukak ≧ 60%); BS EN / EN61000-3-3, GB17743 lan GB17625.1, EAC TP TC 020 | ||||
KEMALANGAN EMC | Selaras karo BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, tingkat industri ringan (kekebalan lonjakan Line-Line 2KV), EAC TP TC 020 | ||||
LAIN |
MTBF | 2394.5K jam min. Telcordia SR-332 (Bellcore); 224.2K jam min. MIL-HDBK-217F (25 ℃) | |||
DIMENSI | 171 * 63 * 37.5mm (L * W * H) | ||||
KEMASAN | 0.77Kg; 18 pcs / 14.9Kg / 0.97CUFT | ||||
CATETAN |
|
OPERASI DIMMING
- DIM + kanggo Blank-Type
- DA + kanggo DA / DA2-jinis
- DIM- kanggo Blank-Type
- DA- kanggo DA / DA2-jinis
CATETAN: DA / DA2-Type ora ana bedane antarane kutub "+" lan "-".
Prinsip redup kanggo output gaya PWM
- Dimming bisa ditindakake kanthi beda-beda siklus tugas saiki output.
Output arus DC
- Siklus tugas(%) = TON/T×100%
- Frekuensi output PWM: 1.47kHz kanggo Blank/Tipe DA 2.5kHz kanggo Tipe DA2
Fungsi dimming 3 in 1 (kanggo Blank-Type)
- Gunakake salah siji saka telung metodologi antarane DIM + lan DIM-: 0 ~ 10VDC, utawa 10V PWM sinyal utawa resistance.
- Dimming sumber saiki saka sumber daya: 100μA (typ.)
Aplikasi aditif 0 ~ 10VDC
Nglamar sinyal PWM 10V aditif (rentang frekuensi 100Hz ~ 3KHz)
Aplikasi resistance aditif
Cathetan
- Min. Siklus tugas saiki output kira-kira 0.15%, lan input dimming kira-kira 6KΩ utawa 0.6VDC, utawa sinyal 10V PWM kanthi siklus tugas 6%.
- Siklus tugas arus output bisa mudhun nganti 0% nalika input dimming kurang saka 6KΩ utawa kurang saka 0.6VDC, utawa sinyal PWM 10V kanthi siklus tugas kurang saka 6%.
Antarmuka DALI (sisih utama; kanggo DA/DA2-Type)
- Aplikasi sinyal DALI antarane DA + lan DA-.
- Protokol DALI kalebu 16 klompok lan 64 alamat.
- Langkah pisanan tetep ing 0.2% saka output
BEBAN OUTPUT vs SUHU
KARAKTERISTIK STATIS/ FAKTOR DAYA (PF) KARAKTERISTIK
- De-rating dibutuhake ing vol input kurangtage.
DISTORSI HARMONIS TOTAL (THD)
- Model 48V, Tcase ing 75 ℃
EFISIENSI vs BEBAN
Seri PWM-90 nduweni efisiensi kerja sing unggul nganti 90.5% bisa digayuh ing aplikasi lapangan.
- Model 48V, Tcase ing 75 ℃
UMUR
Diagram Blokir
Spesifikasi Mekanik
Blank-Tipe
- Nomer kasus: PWM-90P
- Unit: mm
Tipe DA/DA2
Rekomendasi Pitunjuk Pemasangan
Manual Instalasi
Sambungan kanggo Blank-jinis
Ati-ati
- Sadurunge miwiti instalasi utawa pangopènan apa wae, mangga copot sumber daya f ‧ saka sarana. Priksa manawa ora bisa disambungake maneh kanthi ora sengaja!
- Tansah ventilasi sing tepat ing sakubenge unit lan aja tumpukan obyek apa wae. Uga reresik 10-15 cm kudu disimpen nalika piranti jejer minangka sumber panas.
- Orientasi pemasangan liyane saka orientasi standar utawa beroperasi ing suhu sekitar sing dhuwur bisa nambah suhu komponen internal lan mbutuhake de-rating arus output.
- Rating saiki kabel primer / sekunder sing disetujoni kudu luwih gedhe utawa padha karo unit kasebut. Mangga deleng spesifikasi.
- Kanggo pembalap LED kanthi konektor anti banyu, priksa manawa sambungan antarane unit lan peralatan cahya kenceng supaya banyu ora bisa mlebu menyang sistem.
- Kanggo driver LED dimmable, priksa manawa controller dimming sampeyan bisa nyopir unit kasebut. Seri PWM mbutuhake 0.15mA saben unit.
- Tc maks. diidentifikasi ing label produk. Mangga priksa manawa suhu titik Tc ora ngluwihi watesan.
- AJA nyambungake "DIM- menyang Vo-".
- Cocog kanggo panggunaan njero ruangan utawa ruangan ruangan tanpa sinar srengenge langsung. Mangga supaya kacemplungaken ing banyu liwat 30 menit.
- Sumber daya dianggep minangka komponen sing bakal dioperasikake kanthi kombinasi karo peralatan pungkasan. Amarga kinerja EMC bakal kena pengaruh instalasi lengkap, pabrikan peralatan pungkasan kudu nduweni kualifikasi maneh EMC Directive ing instalasi lengkap maneh.