EPEVER EPIPDB-COM-10 Dual Battery PWM Charge Controller

Appearance

| Do not install the controller in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments. |
(Note: connect the components as the 1-6)
|
Icon |
Function |
![]() |
Connect with battery #1. |
![]() |
Connect with battery #2. |
![]() |
Connect with the PV array. |
|
Remote temp. sensor (Optional) |
Remotely measure the battery temperature to regulate the battery voltage. |
|
Local temp. sensor |
Measure ambient temperature. |
|
For battery 1 |
Indicate battery #1 charging status and error. |
|
For battery 2 |
Indicate battery #2 charging status and error. |
|
Remote meter connection |
Connect with a remote meter. |
Note: No RTS; the controller measures ambient temperature by the local temp. sensor. While the controller will obtain data from the RTS automatically after the RTS is connected.
EPIPDB-COM series are common-negative controllers. Negative terminals of the PV array and batteries can be grounded simultaneously, or any negative terminal is grounded. According to the practical application, the negative terminals of the PV array and batteries can also be ungrounded.
However, the grounding terminal on the controller shell must be grounded.
It can shield electromagnetic interference and avoid electric shock to the human body.
CAUTION |
Using a common-negative controller for common-negative systems, such as the RV system, is recommended. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system. |
Mode Setting
| battery type |
mode |
| charging priority | |
| charging frequence |
Three LEDs flash, and each LED indicates different specifications. Choose the LED according to the following information, and then press the button for 5 seconds until the number flashes. And then, choose one number you need and leave it, and the number will be saved.
- 1st LED is for the battery type setting.
1st LED Battery type 1 Sealed battery 2 Gel battery 3 Flooded battery - 2nd LED is for the charging priority setting. Set the percentage for battery #1, and the controller will automatically calculate the rest percentage for battery #2.
2nd LED Battery #1 charging percentage Battery # 2 Charging percentage 0 0% 100% 1 10% 90% 2 20% 80% 3 30% 70% 4 40% 60% 5 50% 50% 6 60% 40% 7 70% 30% 8 80% 20% 9 90%(pre-set) 10% Note: During the normal charging process, the controller charges the battery per the set percentage. If one battery is fully charged (such as battery #1), more charge current will be diverted to the other battery (battery #2). The controller automatically returns to the setting percentage when battery #1 is low voltage.
When the controller detects only one battery, all the charging current will go to this battery automatically. - 3rd LED is for the charging frequency setting.
3rd LED PWM charging frequency 0 25Hz(pre-set) 1 50Hz 2 100Hz
Troubleshooting
| No. | LED Status | Troubleshooting |
| 1 | LED blinking | Short circuit. Please check whether the PV and battery connection is correct. |
| 2 | LED slowly flashing | Fully charged |
| 3 | LED ON | In charging |
| 4 | LED frequent flashing | No charging or any battery is detected. |
| 5 | LED OFF | No battery or system over voltage. |
Technical Information
| Model | EPIPDB-COM-10 | EPIPDB-COM-20 |
| Nominal system voltage |
12/24VDC Auto |
|
| Rated charge current | 10A | 20A |
| Battery Type |
Sealed; Gel; Flooded |
|
| Equalize charging voltage |
Sealed: 14.6V; Gel: No; Flooded: 14.8V |
|
| Boost charging voltage |
Sealed: 14.4V; Gel: 14.2V; Flooded: 14.6V |
|
| Float charging voltage |
Sealed/Gel/Flooded: 13.8V |
|
| Maximum solar voltage |
30V(12V System); 55V(24V System) |
|
| Battery voltage range |
8 ~ 15V |
|
| Boost time |
120 minutes |
|
| Self-consumption |
4mA at night; 10mA at charging |
|
| Communication port |
8-PIN RJ-45 |
|
| Temp. compensation |
-5mV/℃/2V |
|
| Terminals |
4mm2 |
|
| Environment temperature |
-35℃ ~ +55℃ |
|
| Net weight |
250g |
|
Note: The above parameters are measured in the condition of a 12V system. Please double the values in the 24V system.
Mechanical Drawing

Version Number: V3.1
Customer Support
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Tel: +86-752-3889706
E-mail: info@epever.com
Website: www.epever.com

Documents / Resources
![]() |
EPEVER EPIPDB-COM-10 Dual Battery PWM Charge Controller [pdf] User Manual EPIPDB-COM-10, EPIPDB-COM-20, EPIPDB-COM-10 Dual Battery PWM Charge Controller, EPIPDB-COM-10, Dual Battery PWM Charge Controller, Battery PWM Charge Controller, PWM Charge Controller, Charge Controller |



CAUTION