Finglai Manuals & User Guides
Finglai specializes in manufacturing industrial electrical equipment, including temperature controllers, solid-state relays, sensors, switches, and analog ammeters.
About Finglai manuals on Manuals.plus
Finglai Electric provides a comprehensive range of industrial electrical equipment and automation components. Their product catalog includes advanced temperature controllers, solid-state relays, analog and digital ammeters, time switches, switching power supplies, and process controllers. Designed for reliability in demanding environments, Finglai products are widely used in commercial refrigeration systems, power distribution networks, and industrial control cabinets.
Finglai manuals
Latest manuals from manuals+ curated for this brand.
Finglai 44L1 AC Analog Ammeter User Manual
Finglai STC-8000H Temperature Controller User Manual
STC-200 Temperature Controller Instruction Manual
NDK Series Control Transformer Manual
Finglai manuals from online retailers
Finglai S-200-24 Switching Power Supply User Manual
Finglai STC-9200 AC/DC 12V Temperature Controller User Manual
Finglai STC-9200 AC 110V Temperature Controller User Manual
STC-100A Temperature Controller User Manual
STC-8080A Temperature Controller User Manual
Finglai STC-8000H Temperature Controller User Manual
Finglai BK-200VA Control Power Transformer User Manual
Finglai SQ-72 Series Analog Ammeter User Manual
Finglai T80 Series Process Controller User Manual
Finglai ETC-974 Temperature Controller User Manual
Finglai T80 Series Process Controller Instruction Manual
Finglai support FAQ
Common questions about manuals, registration, and support for this brand.
-
How do I enter parameter modification mode on a Finglai STC-8000H?
Press and hold the 'Set' button for more than 3 seconds to enter parameter modifying status. The indicator light will turn on. Save your changes by pressing Rst or wait 30 seconds.
-
What does the E1 error code mean on a Finglai temperature controller?
E1 indicates a memory error, which causes the alarm to activate and system operations to stop. Press the 'Set' button to restore default parameter settings, then reset immediately.
-
Do I need a current transformer (CT) for the Finglai 44L1 AC Ammeter?
Yes, for current ranges above 50A, you must prepare a matching current transformer (CT) with a standard ratio (e.g., 100A/5A or 200A/5A) to ensure measurement accuracy.
-
What happens during an E2 sensor error on Finglai controllers?
E2 indicates a sensor error. The alarm is active and the compressor will operate in a proportional cycle of 15 minutes ON and 30 minutes OFF until the issue is resolved.