Finglai STC-9200
STC-9200 AC 110V Temperature Controller User Manual
Brand: Finglai
Product Overview
The Finglai STC-9200 is an AC 110V temperature controller designed for refrigeration systems, featuring defrost and fan alarm functions. It includes two NTC sensors for accurate temperature measurement and control. This device is suitable for various applications requiring precise temperature management, such as freezers and cold storage units.

Figure 1: Front view of the STC-9200 Temperature Controller, showing the display and control buttons.
Setup and Installation
Proper installation is crucial for the safe and effective operation of the STC-9200 controller. Ensure all power is disconnected before proceeding with wiring.
Mounting
The controller is designed for panel mounting. The perforation dimensions are 71x29 mm. Ensure adequate space for ventilation and wiring connections.
Wiring Diagram
Refer to the wiring diagram below for correct connections. Strictly distinguish the connections interfaces of relay, sensor, and power from one another. Sensor connections and power wires should be kept at a proper distance to avoid interference.

Figure 2: Wiring diagram for the STC-9200 controller. This diagram illustrates connections for compressor, defrost, fan, and two NTC sensors, along with the 110VAC power input.
- Power Supply: Connect 110VAC, 50/60Hz to the designated terminals.
- Compressor Relay: Connect the compressor load to the compressor relay terminals (Contact rating: 8A at 220Vac).
- Defrosting Relay: Connect the defrosting heater load to the defrosting relay terminals (Contact rating: 8A at 220Vac).
- Fan Relay: Connect the fan load to the fan relay terminals (Contact rating: 8A at 220Vac).
- NTC Sensors: Connect the two NTC temperature sensors to their respective terminals. One sensor is typically for storage temperature, and the other for defrosting.
Operating Instructions
The STC-9200 features a user-friendly interface with a three-digit LED display and status indicator lights.

Figure 3: Close-up of the STC-9200 control panel, showing the LED display, SET button, and Up/Down arrow buttons.
Control Panel Overview
- LED Display: Shows the current temperature and parameter values.
- SET Button: Used to enter and confirm parameter settings.
- Up (▲) Button: Used to increase values or navigate menus.
- Down (▼) Button: Used to decrease values or navigate menus.
- Status Indicators:
- SET: Indicates setting mode.
- Refrigeration: Indicates compressor is active.
- Defrost: Indicates defrost cycle is active.
- Fan: Indicates fan is active.
Setting Temperature Parameters
- Press the SET button once to view the current set temperature.
- Press and hold the SET button for 3 seconds to enter parameter setting mode. The display will flash.
- Use the ▲ or ▼ buttons to adjust the desired temperature set point.
- Press the SET button again to confirm and save the setting.
Advanced Parameter Settings (P-Codes)
The STC-9200 has various configurable parameters (P-codes) for fine-tuning its operation, such as defrost cycle duration, fan delay, and alarm thresholds. Consult the detailed instruction sheet provided with the product for a complete list and explanation of these parameters.

Figure 4: The STC-9200 controller packaged with its detailed instruction sheet, which contains comprehensive parameter settings and operational guidelines.
Maintenance
Regular maintenance ensures the longevity and accurate performance of your STC-9200 temperature controller.
- Cleaning: Periodically wipe the control panel with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device.
- Sensor Inspection: Check the temperature sensors for any physical damage or corrosion. Ensure they are securely connected and positioned correctly for accurate readings.
- Ventilation: Ensure the controller's ventilation openings are not obstructed to prevent overheating.
- Wiring Check: Annually inspect all wiring connections for tightness and signs of wear or damage.
Troubleshooting
This section addresses common issues you might encounter with the STC-9200 controller.
| Problem | Possible Cause | Solution |
|---|---|---|
| Display shows "HHH" or "LLL" | Sensor error (open circuit or short circuit) or temperature out of range. | Check sensor connections. Replace sensor if damaged. Ensure temperature is within -50 to 90 ℃ range. |
| Controller not powering on | No power supply or incorrect wiring. | Verify 110VAC power supply. Check wiring according to the diagram. |
| Compressor/Fan/Defrost not activating | Incorrect parameter settings, faulty relay, or load issue. | Review set temperature and differential settings. Check if the corresponding indicator light is on. Inspect wiring to the load. |
| Inaccurate temperature reading | Sensor placement, damaged sensor, or interference. | Ensure sensor is correctly placed and not exposed to direct airflow or heat sources. Check sensor for damage. Keep sensor wires away from power lines. |
If the problem persists after attempting these solutions, please contact customer support.
Specifications
| Parameter | Value |
|---|---|
| Model Number | STC-9200 |
| Measure Range | -50 to 90 ℃ |
| Setting Range | -50 to 50 ℃ |
| Resolution | 0.1 ℃ |
| Accuracy | ±1 ℃ (-40 to 50 ℃), ±2 ℃ (50 to 70 ℃) |
| Supply Voltage | 110Vac, 50/60Hz |
| Power Consumption | Less than 5W |
| Output Types | Three mechanical relays (Compressor, Fan, Defrost) |
| Input Types | Two NTC sensors |
| Panel Size | 75x34.5 mm |
| External Dimensions | 75x34.5x85 mm |
| Perforation Dimensions | 71x29 mm |
| Control Method | ON/OFF Control |
| Setting Method | Touch switch |
| Indication Method | Three-digit LED + Minus digit + Status indicator light |
| Front Panel IP Rating | IP65 |
| Operating Temperature | 0 to 55 ℃ (32 to 131 ℉) |
| Operating Humidity | 20% to 85% RH, non-condensing |
| Storage Temperature | -25 to 75 ℃ (-13 to 167 ℉) |
| Compressor Relay Contact Rating | 8A at 220Vac |
| Fan Relay Contact Rating | 8A at 220Vac |
| Defrosting Relay Contact Rating | 8A at 220Vac |
Warranty and Support
For warranty information and technical support, please refer to the documentation included with your product or contact Finglai customer service. Keep your purchase receipt for warranty claims.
Manufacturer: Yueqing Finglai Electric Co.,Ltd.
Related Documents - STC-9200
![]() |
STC-200 Temperature Controller Instruction Manual Comprehensive instruction manual for the STC-200 temperature controller, covering specifications, wiring, parameter settings, and installation guidelines. |
![]() |
Finglai STC-8000H Temperature Controller User Manual Comprehensive user manual for the Finglai STC-8000H temperature controller, covering technical specifications, parameter settings, wiring diagrams, and safety guidelines. |
![]() |
STC-9200 Digital Temperature Controller: Precise Thermostat for Refrigeration, Incubation & More Discover the GAQQEE STC-9200, a versatile digital temperature controller and thermostat. Featuring high precision, multiple power inputs (12V, 24V, 110V, 220V), and extensive applications for freezers, incubators, and industrial uses. |
![]() |
Diymore STC-3008 Digital Temperature Controller - Dual Display NTC Detailed specifications and user manual for the Diymore STC-3008 digital thermostat controller. Features dual display, NTC sensors, AC 110V/230V compatibility, and instructions for heating/cooling setup, operation, and safety. |
![]() |
STC-3028 Digital Temperature & Humidity Controller - Shenzhen Hongxin Detailed specifications and instructions for the Shenzhen Hongxin STC-3028 digital temperature and humidity controller, suitable for incubators and greenhouses. Features dual display, AC 110-220V input, and 10A relay output. |
![]() |
Li Time 3000W 48VDC 100-110VAC All-in-One Solar Charger Inverter Manual Comprehensive user manual for the Li Time 3000W 48VDC 100-110VAC All-in-One Solar Charger Inverter, covering safety, installation, specifications, operation, troubleshooting, and fault codes. Includes detailed diagrams and parameter settings. |
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.