Finglai ETC-974

Contents

Finglai ETC-974 Temperature Controller User Manual

Model: ETC-974

1. Introduction

The Finglai ETC-974 is a versatile microcomputer temperature controller designed for refrigeration, defrosting, and fan control applications. It features dual NTC sensors for precise temperature monitoring and includes alarm functions for temperature overrange and sensor faults. This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your ETC-974 controller.

2. Product Overview

The ETC-974 controller features a clear digital display and intuitive control buttons for easy programming and monitoring. Its compact design allows for panel mounting in various industrial and commercial refrigeration units.

ETC-974 Temperature Controller, perspective view

Figure 2.1: Perspective view of the ETC-974 Temperature Controller, showing the front panel and side mounting clips.

Front view of ETC-974 Temperature Controller

Figure 2.2: Front view of the ETC-974 Temperature Controller, highlighting the digital display and control buttons (Up, Down, FNC, SET).

Side view of ETC-974 Temperature Controller

Figure 2.3: Side view of the ETC-974 Temperature Controller, showing the orange mounting clips for secure installation.

Bottom view of ETC-974 Temperature Controller

Figure 2.4: Bottom view of the ETC-974 Temperature Controller, showing the terminal block for electrical connections.

3. Specifications

FeatureSpecification
Model NumberETC-974
Measure Range-50 to 120 °C (-58 to 248 °F)
Resolution0.1°C
AccuracyNTC: ±0.5°C (-30°C to 50°C), others: ±1 °C
Supply Voltage Options220VAC, 110VAC (50/60Hz), or 12-24VAC/DC (Note: One option per unit)
Power ConsumptionLess than 5W
Output Types3 Mechanical Relays (Compressor, Fan, Defrosting)
Compressor Relay Contact Rating10A at 220VAC
Fan Relay Contact Rating10A at 220VAC
Defrost Relay Contact Rating10A at 220VAC
Input Types2 NTC sensors (2m cable, included)
Panel Size77mm x 32mm
External Dimensions77mm x 32mm x 58mm
Perforation Dimensions71mm x 29mm
Control MethodON/OFF Control
Setting MethodTouch Switch
Indication MethodThree-digit LED + Minus digit + Status indicator light (set; refrigeration; defrost; fan)
Front Panel IP RatingIP65
Operating Temperature-5 to 55 °C (23 to 131 °F)
Operating Humidity10% to 90% RH, non-condensing
Storage Temperature-25 to 75 °C (-13 to 167 °F)
Display TypeDIGITAL
UseIndustrial
Display Size2.0 - 3.9 Inches

4. Installation and Wiring

Safety Warning: Installation should only be performed by qualified personnel. Ensure all power is disconnected before attempting any wiring to prevent electric shock or damage to the unit.

4.1 Mounting

The ETC-974 is designed for panel mounting. Create a rectangular cutout in your panel with the following dimensions:

  • Length: 71mm
  • Width: 29mm

Insert the controller into the cutout and secure it using the orange mounting clips on the sides of the unit.

4.2 Wiring Diagram

Refer to the wiring diagram below for proper electrical connections. Ensure that the power supply matches the voltage rating of your specific ETC-974 unit (220VAC, 110VAC, or 12-24VAC/DC).

Detailed wiring diagram for ETC-974 Temperature Controller

Figure 4.1: Detailed wiring diagram for the ETC-974 Temperature Controller. This diagram illustrates connections for power supply, compressor, fan, defrost, and sensors.

Terminal Connections:

  • Terminals 1 & 2: Power Supply Input (Line)
  • Terminals 3 & 4: Compressor Output (Rated 10A at 250V)
  • Terminals 5 & 6: Fan Output (Rated 10A at 250V)
  • Terminals 7 & 8: Defrost Output (Rated 10A at 250V)
  • Terminals 9 & 10: NTC Sensor Inputs (Pb1, Pb2)

Connect the two NTC temperature sensors (included) to terminals 9 and 10. Ensure all connections are secure and properly insulated.

5. Operation

The ETC-974 controller is operated using the four buttons on the front panel: Up arrow (∧), Down arrow (∨), FNC (Function), and SET.

5.1 Button Functions

  • ∧ (Up Arrow): Increases values, navigates up in menus.
  • ∨ (Down Arrow): Decreases values, navigates down in menus.
  • FNC (Function): Exits current setting mode, accesses advanced functions (long press).
  • SET: Enters setting mode, confirms selection.

5.2 Basic Temperature Setting

To set the desired temperature:

  1. Press the SET button once. The current set temperature will flash on the display.
  2. Use the ∧ or ∨ buttons to adjust the temperature to your desired value.
  3. Press the SET button again to confirm and save the new setting.

5.3 Status Indicators

The LED display includes status indicators for:

  • SET: Indicates the controller is in setting mode.
  • Refrigeration: Indicates the compressor is active.
  • Defrost: Indicates the defrost cycle is active.
  • Fan: Indicates the fan is active.

For detailed programming of defrost cycles, fan operation, and alarm parameters, please refer to the comprehensive PDF manual linked in the "Warranty and Support" section.

6. Maintenance

To ensure optimal performance and longevity of your ETC-974 temperature controller, follow these maintenance guidelines:

  • Cleaning: Regularly wipe the front panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or buttons.
  • Sensor Inspection: Periodically check the NTC sensors and their cables for any signs of damage, corrosion, or loose connections. Ensure they are securely placed in their intended monitoring locations.
  • Ventilation: Ensure that the controller's housing has adequate ventilation to prevent overheating. Do not obstruct any vents.
  • Power Supply: Verify that the power supply voltage remains stable and within the specified range for your unit.

7. Troubleshooting

If you encounter issues with your ETC-974 controller, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Display is blank or unit is unresponsive.No power supply or incorrect voltage.Check power connections and ensure the supply voltage matches the unit's requirements. Verify circuit breaker or fuse.
Temperature reading is inaccurate or erratic.Faulty or improperly connected NTC sensor.Check sensor wiring for loose connections or damage. Replace sensor if necessary. Ensure sensors are correctly positioned.
Compressor/Fan/Defrost not activating.Incorrect temperature settings, relay failure, or wiring issue.Verify set temperature and differential settings. Check wiring to the respective loads. If relays are suspected, professional inspection is recommended.
Alarm continuously active.Temperature outside set limits or sensor fault.Check the actual temperature against the alarm set points. Inspect sensors for faults. Refer to the full manual for specific alarm codes if displayed.

7.1 User Tips

  • For optimal performance, ensure the NTC sensors are placed in locations that accurately represent the temperature you wish to control, away from direct airflow or heat sources that could cause false readings.
  • When setting temperature differentials, consider the application to prevent rapid cycling of the compressor, which can reduce its lifespan.
  • Always double-check wiring connections, especially for power and load outputs, to prevent damage to the controller or connected equipment.

8. Warranty and Support

For comprehensive details regarding warranty, advanced programming, and further technical support, please refer to the official product manual:

Download ETC-974 Defrost Temperature Controller Manual (PDF)

You can also visit the Finglai Electric store for additional product information and support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.