Finglai STC-9200 Temperature Controller User Manual

Model: STC-9200

1. Introduction

The Finglai STC-9200 is a versatile microcomputer temperature controller designed for industrial and commercial refrigeration systems. It integrates control functions for refrigeration, defrosting, and fan operation, along with dual sensor inputs and alarm capabilities for temperature overrange and sensor faults. This manual provides essential information for the proper installation, operation, and maintenance of your STC-9200 controller.

Finglai STC-9200 temperature controller and two NTC sensors
Figure 1: STC-9200 Temperature Controller with NTC Sensors

2. Main Functions and Features

  • Multi-control modes for refrigeration, defrost, and fan.
  • Separate user and administrator menus for convenient operation and high-level management.
  • Differential control mode with 0.1°C temperature display resolution.
  • Multiple protection and alarm modes (optional).
  • Copy key function (optional).
  • Equipped with two NTC temperature sensors.
Front panel of the STC-9200 controller showing display and control buttons
Figure 2: Front Panel View of STC-9200

3. Technical Specifications

Parameter Value
Model NumberSTC-9200
Measure Range-50 to 90 °C
Setting Range-50 to 50 °C
Resolution0.1 °C
Accuracy±1 °C (-40 to 50 °C), ±2 °C (50 to 70 °C)
Supply Voltage Options220VAC, 110VAC, 12VAC/DC, 24VAC/DC (one option per unit)
Power ConsumptionLess than 5W
Output TypesThree mechanical relays (Compressor, Fan, Defrost)
Relay Capacity (Compressor, Fan, Defrost)8A at 220Vac (each)
Input Types2pcs 2m cable NTC sensors
Panel Size75 x 34.5 mm
External Dimensions75 x 34.5 x 85 mm
Perforation Dimensions71 x 29 mm
Control MethodON/OFF Control
Setting MethodTouch switch
Indication MethodThree-digit LED + Minus digit + Status indicator light (set, refrigeration, defrost, fan)
Front Panel IP RatingIP65
Operating Temperature0 to 55 °C (32 to 131 °F)
Operating Humidity20% to 85% RH, non-condensing
Storage Temperature-25 to 75 °C (-13 to 167 °F)

4. Package Contents

Upon opening the package, you should find the following items:

  • 1 x STC-9200 Temperature Controller
  • 2 x NTC Temperature Sensors (2m cable each)
  • 1 x Instruction Manual (this document or similar)
STC-9200 controller, sensors, and instruction manual in packaging
Figure 3: Package Contents

5. Installation and Wiring

The STC-9200 controller is designed for panel mounting. Ensure the perforation dimensions (71 x 29 mm) are met for a secure fit. Before proceeding with wiring, ensure all power sources are disconnected to prevent electrical shock.

5.1 Wiring Diagram

Rear view of the STC-9200 controller with detailed wiring diagram and connection notes
Figure 4: STC-9200 Wiring Diagram

Refer to the diagram above for proper connections. The terminals are labeled as follows:

  • Terminals 1 & 2: Compressor Relay Output (10A)
  • Terminals 3 & 4: Defrost Relay Output (10A)
  • Terminals 5 & 6: Fan Relay Output (10A)
  • Terminals 7 & 8: Power Supply (e.g., 220VAC, 110VAC, 24V, 12V depending on model)
  • Terminals 9 & 10: Room Probe (NTC Sensor 1)
  • Terminals 11 & 12: Defrost Probe (NTC Sensor 2)

5.2 Important Wiring Notes

  • Strictly distinguish the interface of the relay, sensor, and power connections. Incorrect wiring can damage the unit or connected equipment.
  • Ensure proper distance is maintained between sensor down-lead wires and power wires to avoid interference.
  • Verify that the supply voltage matches the specific model of your STC-9200 controller (e.g., 220VAC, 110VAC, 24VAC/DC, or 12VAC/DC).

6. Operation

6.1 Keypad Functions

Keystroke Operation Function Description
SET (short press)View current temperature
SET (long press)Enter/Exit parameter setting
▲Increase value
▼Decrease value
SET + ▲Enter administrator menu
SET + ▼Enter administrator menu
▲ + ▼Lock/Unlock keypad

6.2 Indicator Lights

Light (Icon) Status Description
Refrigeration (Snowflake)OnRefrigeration working
Refrigeration (Snowflake)FlashCompressor delay
Defrost (Water drops)OnDefrost working
Defrost (Water drops)FlashDefrost delay
Fan (Fan blades)OnFan working
Fan (Fan blades)FlashFan delay
Set (SET)OnParameter setting
Set (SET)FlashParameter setting

6.3 Basic Parameter Settings

To adjust parameters, long press the SET button until the display flashes. Use the ▲ and ▼ buttons to navigate through parameters (F1, F2, etc.) and adjust their values. Press SET again to confirm and move to the next parameter, or long press SET to exit the setting mode.

Menu Description Default
F1Temperature setting0
F2Differential setting2
F3Compressor delay time5
F4Defrost time0
F5Defrost interval0
F6Defrost temperature0
F7Fan delay time0
F8Fan working time0
F9Fan stop time0
FAAlarm temperature0
FBAlarm differential0
FCSensor calibration0
FDSensor fault alarm0
FECompressor protection0
FFDefrost protection0
FGFan protection0

For detailed descriptions of each parameter and advanced settings, please refer to the full PDF manual.

7. Maintenance

  • Cleaning: Regularly wipe the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Sensor Inspection: Periodically check the NTC sensors and their cables for any signs of damage or wear. Ensure they are securely connected.
  • Ventilation: Ensure the controller's ventilation openings are not obstructed to prevent overheating.
  • Power Supply: Verify that the power supply remains stable and within the specified voltage range for your model.

8. Troubleshooting

Problem Possible Cause Solution
Controller not powering on No power supply; Incorrect voltage; Loose wiring Check power connection; Verify voltage matches unit; Inspect wiring connections
Inaccurate temperature reading Faulty sensor; Sensor placed incorrectly; Interference Check sensor connection; Reposition sensor; Ensure sensor wires are away from power lines
Compressor/Fan/Defrost not activating Incorrect parameter settings; Relay fault; Wiring error Review F1-F9 parameters; Check relay connections; Consult full manual for specific fault codes
Keypad unresponsive Keypad locked Press ▲ + ▼ simultaneously to unlock the keypad

9. User Tips

  • This controller is commonly used for industrial and commercial refrigerators, managing the compressor, defrost cycle, and circulation fan.
  • Always double-check the voltage specification of your STC-9200 unit (e.g., 12V, 24V, 110V, 220V) before connecting power to avoid damage.
  • For optimal performance, ensure the room probe is placed in a location representative of the overall temperature, and the defrost probe is correctly positioned on the evaporator coil.

10. Warranty and Support