Introduction

The STI STI-9764-R Horn/Strobe Damage Stopper is a robust, red, wall-mounted protective cage designed to safeguard horn/strobe units from accidental damage, vandalism, or tampering. This device is ideal for use in public areas, schools, hospitals, and other environments where fire safety equipment needs additional protection. Its durable construction ensures long-lasting performance and reliable protection for critical alarm components.

Safety Information

Package Contents

Verify that all components are present before beginning installation:

Setup and Installation

Follow these steps for proper installation of the damage stopper:

  1. Prepare the Mounting Surface: Identify a suitable wall location that provides adequate support for the damage stopper and the horn/strobe unit. Ensure the surface is clean and free of obstructions.
  2. Position the Damage Stopper: Hold the damage stopper in the desired position over the horn/strobe unit. Ensure the unit is fully enclosed and there is sufficient clearance for its operation. Mark the drilling points through the mounting holes on the damage stopper.
  3. Drill Pilot Holes: Using an appropriate drill bit for your wall type, drill pilot holes at the marked locations. If installing into drywall, insert wall anchors as needed.
  4. Secure the Damage Stopper: Align the damage stopper with the drilled holes. Insert the provided mounting screws (or suitable alternatives) through the mounting holes and tighten them securely. Do not overtighten.
  5. Verify Installation: Gently tug on the installed damage stopper to ensure it is firmly attached to the wall and does not wobble. Confirm that the horn/strobe unit is protected and its functionality is not impaired.
Red wire cage, the STI STI-9764-R Horn/Strobe Damage Stopper, designed to protect a horn/strobe unit.

Image: The STI STI-9764-R Horn/Strobe Damage Stopper, a red wire cage designed for wall mounting to protect horn/strobe units.

Operating Instructions

The STI STI-9764-R is a passive protective device. It does not require any operational steps once installed. Its function is to provide a physical barrier against impact and tampering for the horn/strobe unit it encloses. Ensure the horn/strobe unit itself is operating correctly according to its own manufacturer's instructions.

Maintenance

The damage stopper requires minimal maintenance:

Troubleshooting

As a passive device, the damage stopper has limited troubleshooting scenarios:

ProblemPossible CauseSolution
Damage stopper is loose on the wall.Mounting screws are loose or wall anchors are failing.Tighten mounting screws. If necessary, remove, repair wall, and re-install with appropriate anchors.
Horn/strobe unit is still being damaged.Damage stopper is improperly installed or insufficient for the type of impact.Verify proper installation. Consider if a more robust protective solution is required for the environment.
Damage stopper is bent or broken.Sustained significant impact.Replace the damage stopper immediately to ensure continued protection.

Specifications

AttributeDetail
Model NumberSTI-9764-R (SSTI9764R)
BrandSTI
Product TypeHorn/Strobe Damage Stopper
Mounting TypeWall Mount
ColorRed
MaterialDurable wire construction
UPC662950018124
Date First AvailableMay 31, 2023

Warranty and Support

For information regarding warranty coverage and technical support for your STI STI-9764-R Horn/Strobe Damage Stopper, please contact STI directly through their official website or customer service channels. Keep your purchase receipt as proof of purchase for any warranty claims.

Manufacturer: STI

Website: www.sti-usa.com (Note: This is a general placeholder for a manufacturer's website. Please refer to the product packaging or official STI documentation for the most accurate contact information.)

Related Documents - STI-9764-R

Preview STI Clock/Bell Damage Stopper and Wire Guard Catalog
Safety Technology International (STI) provides installation instructions for the STI-9635, STI-9636, and STI-9637 Clock/Bell Damage Stopper. The document also features a comprehensive catalog of STI wire guards for various applications including smoke detectors, PIR sensors, exit signs, emergency lights, beacons, sounders, and miscellaneous uses, detailing model numbers and dimensions.
Preview STI Universal Stopper STI-13000 & STI-14000 Series Installation Guide
Installation guide and specifications for STI Universal Stopper models STI-13000 and STI-14000 series, covering installation notes, technical specifications, mounting options, wiring, and warranty.
Preview STI Stopper II Series: Protective Cover for Fire Alarm Pull Stations - Installation & Specifications
Comprehensive guide to the STI Stopper II Series protective cover for manual fire alarm pull stations. Features include physical damage protection, optional audible alarm, weather resistance (NEMA 3R), and ADA compliance. Details installation steps, specifications, testing approvals, and maintenance.
Preview STI Universal Stopper Installation Guide: STI-13000 & STI-14000 Series
Comprehensive installation guide for STI Universal Stopper models STI-13000 and STI-14000, covering specifications, mounting options, horn details, and safety information.
Preview STI Exit Stopper: Security and Theft Prevention Device
Learn about the STI Exit Stopper (STI-6400 series), a versatile security device designed to deter theft and alert to unauthorized exits or entries through emergency doors. Features include adjustable alarms, durable construction, and easy installation.
Preview STI-6400WIR Series Exit Stopper Installation and Features
Comprehensive guide to the STI-6400WIR Series Exit Stopper, detailing its features, specifications, installation instructions, and switch settings for enhanced door security and alarm management.