Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the DieseRC 4 Channels Wireless Relay Remote Control Switch. This device is designed for remote control applications, offering stable and reliable performance with high reception sensitivity. It features multiple operating modes and independent relay control, making it suitable for various home, farm, factory, and office applications.

Product Overview

The DieseRC wireless relay remote control switch system includes a receiver module and two keyfob transmitters. The receiver features four independent 10A relays with normally open, common, and normally closed terminals, providing flexible control options.

DieseRC 4 Channels Wireless Relay Remote Control Switch with two keyfob transmitters

Figure 1: The DieseRC 4 Channels Wireless Relay Remote Control Switch receiver and two included keyfob transmitters.

Key Features:

  • 433Mhz RF Wireless Control: Ensures stable and reliable performance with high reception sensitivity (> -105dBm).
  • Extended Range: Strong signal can pass through walls, floors, and doors, with control up to 50 meters without obstacles.
  • Multiple Operating Modes: Supports Momentary, Toggle, and Latched modes, easily configurable to suit various application needs.
  • Independent 10A Relays: Four independent relays, each with Normally Open (NO), Common (COM), and Normally Closed (NC) terminals for versatile wiring.
  • Wide Voltage Compatibility: Receiver operates on DC 6V~30V, compatible with 5V, 12V, 24V, and 30V systems.
  • High-Quality Components: Relays designed for over 100,000 operations, and high-power terminals withstand 10A current.
  • Memory Capacity: Each receiver can store up to 20 transmitters.

Specifications

FeatureDetail
BrandDieseRC
Operation ModeToggle, Momentary, Latched
Current Rating10 Amps
Operating VoltageDC 6V~30V (compatible with 5V, 12V, 24V, 30V)
Contact TypeNormally Open, Common, Normally Closed
Connector TypeWireless (433Mhz RF)
TerminalScrew
Circuit Type4-way
Actuator TypePush Button (on remote)
Contact MaterialCopper
Package Dimensions5.16 x 3.23 x 2.2 inches
Weight7.05 ounces
Batteries2 x 12V batteries (included for transmitters)

Setup and Installation

Proper installation is crucial for the safe and effective operation of your wireless relay switch. Always ensure power is disconnected before making any wiring connections.

1. Wiring the Receiver:

The receiver features large screw terminals for easy and secure wiring. It supports various cable types including Single-Strand Hard Wire (BV), Stranded Hard Wire (RV), and Stranded Flexible Wire (BVR).

Wiring diagram showing different cable types and the screw terminals on the receiver

Figure 2: Illustration of compatible cable types and the accessible screw terminals for wiring.

The receiver has input terminals for DC 5V-30V power supply (VIN and GND). The output consists of four independent relays, each with three terminals: Normally Open (NO), Common (COM), and Normally Closed (NC). These are potential-free (dry contact) outputs.

Four wiring diagrams for different applications: DC device, DC motor, AC device, AC motor for lamp, curtain, and garage

Figure 3: Examples of wiring configurations for various applications, including DC devices, DC motors, AC devices, and AC motors (e.g., for lamps, curtains, or garage doors).

2. Pairing Transmitters (Learning Signal):

The receiver and transmitters need to be paired to establish communication. The pairing process varies slightly depending on the desired operating mode (Momentary, Toggle, or Latched).

Diagrams showing how to set up Momentary, Toggle, and Latched modes by pressing the learning button and remote buttons

Figure 4: Step-by-step instructions for pairing the remote control with the receiver for Momentary, Toggle, and Latched operating modes.

  1. Momentary Mode (Press and Hold):
    • Press the learning button on the receiver 1 time.
    • Wait approximately 3 seconds.
    • Press button "A" on the remote control.
    • Press button "B" on the remote control. Pairing successful.
  2. Toggle Mode (Press On, Press Off):
    • Press the learning button on the receiver 2 times.
    • Wait approximately 3 seconds.
    • Press button "A" on the remote control.
    • Press button "B" on the remote control. Pairing successful.
  3. Latched Mode (Press "A" for ON, Press "B" for OFF):
    • Press the learning button on the receiver 3 times.
    • Wait approximately 3 seconds.
    • Press button "A" on the remote control.
    • Press button "B" on the remote control. Pairing successful.

    Note: Latched mode typically requires a remote control with at least two buttons for each relay pair (one for ON, one for OFF). For a 4-channel receiver, this means buttons A/B control relay 1, and C/D control relay 2, and so on.

After successful pairing, test the remote control to ensure the desired operation mode is active.

Operating Modes

The DieseRC wireless relay switch supports three distinct operating modes, offering flexibility for various applications.

Diagrams illustrating Momentary, Toggle, and Latched operating modes

Figure 5: Visual representation of the three operating modes: Momentary, Toggle, and Latched.

  1. Momentary Mode:

    In this mode, the relay remains activated only as long as the remote control button is pressed. Releasing the button deactivates the relay. This is ideal for applications like momentary door openers or temporary light activation.

  2. Toggle Mode:

    Pressing the remote control button once activates the relay, and it remains active until the same button is pressed again to deactivate it. This mode is suitable for on/off control of lights, fans, or other devices.

  3. Latched Mode:

    In Latched mode, one button on the remote activates a relay, and another button deactivates it. For example, pressing button "A" turns Relay 1 ON, and pressing button "B" turns Relay 1 OFF (while simultaneously turning Relay 2 ON if configured for a pair). This mode is useful for applications requiring distinct ON and OFF commands, such as motor direction control.

Maintenance

To ensure the longevity and optimal performance of your DieseRC wireless relay switch, follow these general maintenance guidelines:

  • Keep Dry: Protect the receiver and transmitters from moisture and humidity. Water can damage internal electronic components.
  • Clean Gently: Use a soft, dry cloth to clean the exterior of the devices. Avoid using harsh chemicals or abrasive cleaners.
  • Battery Replacement: If the remote control's range decreases or it becomes unresponsive, replace the 12V batteries in the transmitters.
  • Avoid Extreme Temperatures: Do not expose the devices to excessively high or low temperatures, as this can affect performance and lifespan.
  • Secure Connections: Periodically check wiring connections to ensure they are secure and free from corrosion.

Troubleshooting

If you encounter issues with your DieseRC wireless relay switch, refer to the following common troubleshooting steps:

  1. Device Not Responding to Remote:
    • Check Batteries: Ensure the remote control batteries are not depleted. Replace if necessary.
    • Re-pair Remote: The pairing might have been lost. Follow the "Pairing Transmitters" steps in the Setup section to re-pair the remote.
    • Obstacles/Range: Ensure there are no significant metal objects or thick walls between the remote and the receiver that could block the RF signal. While designed for good range, extreme interference can occur.
    • Power to Receiver: Verify that the receiver is properly powered (DC 5V-30V) and its indicator light is on.
  2. Relay Not Activating/Deactivating Correctly:
    • Wiring Check: Double-check all wiring connections to the relay terminals (NO, COM, NC) and ensure they match your intended circuit diagram.
    • Operating Mode: Confirm that the receiver is set to the correct operating mode (Momentary, Toggle, or Latched) for your application. If unsure, reset the receiver and re-pair in the desired mode.
    • Load Compatibility: Ensure the connected load (e.g., motor, lamp) is within the 10A current rating of the relay. Overloading can prevent proper operation or damage the relay.
  3. Remote Control Buttons Not Lighting Up:
    • This typically indicates a dead battery in the remote. Replace the 12V battery.
  4. Resetting the Receiver:

    If you experience persistent issues or wish to clear all paired remotes, you can reset the receiver to its factory default state.

    Diagram showing how to reset the receiver by pressing the learning button 8 times

    Figure 6: To reset the receiver, press the learning button 8 times consecutively.

    After resetting, all previously paired remotes will be cleared, and you will need to re-pair them according to the "Pairing Transmitters" instructions.

Warranty and Support

DieseRC is committed to providing high-quality products and excellent customer service. While specific warranty details are not provided in this manual, DieseRC aims to offer perfect after-sales service and assist customers with any remote control related issues.

For technical support, troubleshooting assistance beyond this guide, or warranty inquiries, please contact DieseRC customer service through the platform where you purchased the product or refer to the contact information provided with your product packaging.

Manufacturer: DieseRC

Please retain your purchase receipt for warranty purposes.

© 2024 DieseRC. All rights reserved.