DieseRC 1204 Relay Remote Control Switch - Product Manual
Product Information
Type: 1204
Working Voltage: DC 12V
Input/Output Voltage: 1~250V
Output Type: Passive output
Quiescent Current: <5MA
Max Current: 10A
Technical Data:
- RF Frequency: 433MHz
- Working Temperature: -30~+80°C
- Receiving Sensitivity: >97dbm
- Amount of Storage: 20 pieces
- Support Encoding: 1527 Leaning code, 2262 fixed code
- RF Operating Mode: ASK superheterodyne wireless reception
- Receiving Range: Open space is more than 50 meters
- Remote Operating Mode: Momentary Mode/Toggle Mode/Latched Mode
- Indicator Light: Yes
- Antenna: Yes
Relay Specifications: SRD-12VDC-SL-C, SONGLE, 10A 125VAC, 10A 250VAC, 10A 30VDC, 10A 28VDC
Pin Descriptions:
- NO: Normally open pin
- COM: Common pin
- NC: Normally closed pin
Wiring Diagram
The product features wiring diagrams illustrating connections for AC and DC devices. The diagrams show input power (DC 12V), output terminals (NO, COM, NC), and connections for AC devices and DC devices/motors.
Operating Modes and Programming
The switch supports three operating modes: Momentary, Toggle, and Latched.
Momentary Mode
Description: Press and hold a button on the remote; the corresponding relay turns on. Release the button; the relay turns off.
Programming:
- Press the learning button on the receiver once. The indicator LED will light up.
- Press button "A" on the remote transmitter. The LED will flash several times and then turn off.
Toggle Mode
Description: Press a button on the remote; the corresponding relay turns on. Press the same button again; the relay turns off.
Programming:
- Press the learning button on the receiver twice. The indicator LED will light up.
- Press button "A" on the remote transmitter. The LED will flash several times and then turn off.
Latched Mode
Description: Press button "A"; relay "1" turns on. Press button "B"; relay "2" turns on, and relay "1" turns off simultaneously. (Requires a remote with at least 5 buttons).
Programming:
- Press the learning button on the receiver three times. The indicator LED will light up.
- Press button "A" on the remote transmitter. The LED will flash several times and then turn off.
Resetting
To reset all paired remote controls:
- Press the learning button on the receiver 8 times. The indicator LED will flash several times and then turn off.
Troubleshooting
If the receiver and transmitter are not operating normally, consider the following:
- Battery Power: Check if the remote transmitter batteries are low (LED does not light up or is dim).
- Wiring: Ensure the receiver is wired correctly.
- Reprogramming: Reprogram the receiver and transmitter, as this often resolves issues.
- Further Assistance: If problems persist, contact DieseRC customer service.
Customer Service
Work volts: DC 12V
Max current: 10Amp
For any questions regarding the products, please contact DieseRC:
Email: dieseelectronic@163.com
WhatsApp: +86 13502278583 / +86 18138805271
Address: 1203, Building T19, Fangzhilonghuwan, Sanhuan South Road, Huicheng District, Huizhou City, Guangdong Province, China 516000
Certifications: CE, FCC, UKCA