Altronix ACM8CB

Altronix Power Module ACM8CB

Output Access Power Controller Module

Introduction

The Altronix ACM8CB is an advanced 8-output access power controller module designed to manage power distribution for various access control devices. This module efficiently converts input voltage (12 to 24 Volt AC or DC) to provide regulated output power, ensuring reliable operation of connected equipment. It is built with durable phenolic or fiberglass material, offering robust performance in demanding environments.

Key Features

Setup and Installation

Proper installation is crucial for the safe and efficient operation of the ACM8CB module. Always ensure power is disconnected before beginning any installation procedures.

  1. Mounting: Securely mount the ACM8CB module within an appropriate enclosure, ensuring adequate ventilation. Use non-conductive standoffs if mounting directly to a metal surface.
  2. Power Input Connection: Connect the 12-24V AC or DC power source to the designated input terminals on the module. Observe correct polarity for DC input.
  3. Output Device Connection: Connect your access control devices (e.g., locks, readers, sensors) to the eight individual output terminals. Each output is clearly labeled (Output 1-8). Ensure correct wiring for each device as per its manufacturer's instructions.
  4. Trigger Input (Optional): If utilizing the trigger feature, connect the trigger source to the designated trigger input terminals. This allows for external control over the power outputs.
  5. Grounding: Ensure the module and all connected devices are properly grounded according to local electrical codes.
  6. Initial Power-Up: After all connections are verified, apply power to the module. Observe the status indicators (LEDs) for proper operation.
Top view of Altronix ACM8CB power controller module with labeled terminals and components.

Figure 1: Top view of the Altronix ACM8CB module, showing the input and output terminals, fuses, and LED indicators. Note the clearly marked output sections (Output 1-8) and the trigger input area.

Operating Instructions

The ACM8CB module operates by distributing power to connected devices based on its configuration and trigger inputs.

Underside view of Altronix ACM8CB power controller module, showing circuit board details and components.

Figure 2: Underside view of the Altronix ACM8CB module, providing a closer look at the circuit board layout and various electronic components, including the PTCs (Positive Temperature Coefficient resettable fuses) and relays.

Maintenance

The Altronix ACM8CB module is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

Troubleshooting

ProblemPossible CauseSolution
No power to any output.No input power; main fuse blown; faulty power supply.Verify input power connection and source. Check and replace the main fuse if necessary. Test the power supply.
Specific output not working.Blown output fuse; short circuit on output; faulty connected device.Check and replace the specific output fuse. Disconnect the device to check for short. Test the connected device.
LED indicators not illuminating.No power; faulty LED; module malfunction.Verify power input. If power is present and LEDs are off, contact technical support.
Module overheating.Overload on outputs; insufficient ventilation; internal fault.Reduce load on outputs. Ensure proper airflow around the module. If problem persists, contact technical support.

Specifications

AttributeDetail
Model NumberACM8CB
Product TypeAccess Power Controller Module
Input Voltage12 to 24 Volt AC or DC
Output Voltage12 to 24 Volt AC or DC
Number of Outputs8
MaterialPhenolic or Fiberglass
Dimensions (L x W x H)4.50 In x 8.00 In x 1.25 In
Weight11.18 ounces
StandardsUL RECOGNIZED, UL294
ManufacturerALTRONIX
Date First AvailableDecember 17, 2008

Warranty and Support

For warranty information and technical support regarding your Altronix ACM8CB module, please refer to the official Altronix website or contact their customer service department directly. Keep your purchase receipt and product serial number handy when seeking support.

Altronix provides comprehensive support for their products, including technical assistance and documentation. For the most up-to-date information, visit www.altronix.com.

Related Documents - ACM8CB

Preview Altronix MaximalFD Series PTC Access Power Controllers Installation Guide
Installation guide for Altronix MaximalFD Series Single Power Supply Access Power Controllers (PTC), including Maximal3FD, Maximal5FD, and Maximal7FD models. Covers features, installation, maintenance, wiring, and specifications.
Preview Altronix T2PXK78 & T2PXK78D Trove Paxton Access & Power Integration Kit Installation Guide
Comprehensive installation guide for Altronix Trove Paxton kits (T2PXK78, T2PXK78D). Learn how to set up advanced access control and power integration systems featuring Altronix power supplies, controllers, and Paxton Net2 Plus modules.
Preview Altronix/Honeywell ProWatch/WinPak Kits Installation Guide - T2HWK78V, T2HWK78DV, T3HWK7516V, T3HWK7516DV
Comprehensive installation guide for Altronix and Honeywell ProWatch/WinPak access control kits, including T2HWK78V, T2HWK78DV, T3HWK7516V, and T3HWK7516DV models. Covers product overview, configuration, installation instructions, hardware, and enclosure dimensions.
Preview Altronix Trove Access & Power Integration Enclosure Installation Guide
Comprehensive installation guide for Altronix Trove1SA1 and Trove2SA2 enclosures with Altronix/SALTO backplanes, designed for integrating access control and power supply systems. Includes specifications, mounting instructions, and module configuration details.
Preview Altronix Trove2/Mercury Kits with Fused Outputs Installation Guide
Installation guide for Altronix Trove2/Mercury kits, detailing various fused output models, configuration options, and assembly instructions for access control systems. Includes overview, configuration charts, installation steps, and enclosure dimensions.
Preview Altronix DL1 Door Control Timer: Specifications and Installation Guide
Detailed specifications and installation instructions for the Altronix DL1 Door Control Timer, featuring adjustable timing, relay output, and versatile voltage operation.