Installation Guide for Altronix models including: T2HWK78V 8 Door Kit with Fused Outputs, T2HWK78V, 8 Door Kit with Fused Outputs, Kit with Fused Outputs, Fused Outputs
2 feb 2023 — T3HWK7516V. 16 Door Kit with Fused Outputs. Fully assembled kit includes: - Trove3 enclosure with THW3 Altronix/Honeywell backplane.
Altronix T3HWK7516V | 16-Door Altronix/Honeywell Access and
File Info : application/pdf, 8 Pages, 1.02MB
DocumentDocumentAccess & Power Integration Altronix/Honeywell ProWatch/WinPak Kits Models Include: T2HWK78V 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with THW2 Altronix/Honeywell backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) ACM8 - Fused Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module T2HWK78DV 8 Door Kit with PTC Outputs Fully assembled kit includes: - Trove2 enclosure with THW2 Altronix/Honeywell backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) ACM8CB - PTC Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8CB - Dual Input PTC Power Distribution Module T3HWK7516V 16 Door Kit with Fused Outputs Fully assembled kit includes: - Trove3 enclosure with THW3 Altronix/Honeywell backplane and THWD2 Honeywell door backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) AL1012XB220 - Power Supply/Charger - Two (2) ACM8 - Fused Access Power Controllers - One (1) PD8UL - Fused Power Distribution Module - One (1) RSB2* - Rocker Switch Bracket with Two (2) Rocker Switches T3HWK7516DV 16 Door Kit with PTC Outputs Fully assembled kit includes: - Trove3 enclosure with THW3 Altronix/Honeywell backplane and THWD2 Honeywell door backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) AL1012XB220 - Power Supply/Charger - Two (2) ACM8CB - PTC Access Power Controllers - One (1) PD8ULCB - PTC Power Distribution Module - One (1) RSB2* - Rocker Switch Bracket with Two (2) Rocker Switches Installation Guide All registered trademarks are property of their respective owners. More than just power.TM Rev. THWLKV_012623 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix Trove Honeywell kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. All kits accommodate a variety of Honeywell modules for up to eight (T2HWK78(D)) or sixteen (T3HWK7516(D)) doors in a single enclosure. Configuration Chart: Additional Fused (PTC) Outputs ACM8(CB) Board Input Fuse Rating ACM8(CB) Board Output Fuse (PTC) Rating PDS8(CB) Board Input Fuse (PTC) Rating PDS8(CB) Board Output Fuse(PTC) Rating PD8UL(CB) Board Output Fuse (PTC) Rating Altronix Model Number Maximum Supply Current for Main Outputs on Power Power Power Supply Nominal Fail-Safe/ 220VAC Supply Supply board DC Fail- 60Hz Board Board and ACM8(CB) Output Secure Input Input Battery Access Power Voltage or Dry Current Fuse Fuse Controllers' Range Form "C" (A) Rating Rating outputs (VDC) Outputs T2HWK78V 2.5 15A/ 32V 24VDC @ 9.7A 20.1726.4 8 8 T2HWK78DV 5A/ T3HWK7516V 3.8 T3HWK7516DV 250V 15A/ 32V 24VDC @ 9.4A 12VDC @ 10A 20.1726.4 9.713.2 16 8 2.5A/ 10A/ 3A/ 10A/ 250V 32V 32V 250V 2.5A 9A 2.5A 2.5A/ 10A/ 250V 250V 2.5A 3.5A/ 250V 2.5A Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. If your application requires a raised backplane, re-mount it using metal spacers and screws (provided). 2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in Fig. 1 desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Enclosure 4. Mount Honeywell modules to backplane(s), refer to pages 3, 4, 5. 5. Refer to the XBV Power Supply/Charger Installation Guide for AL1024XB2V and Edge of Enclosure AL1012XB220 and corresponding Sub-Assembly Installation Guides for ACM8(CB), PDS8(CB), VR6 and PD8UL(CB) for further installation instructions. Tamper Switch (included) Hardware: Nylon Spacer | 5/16" Pan Head Screw | Lock Nut To Access Control Panel or UL Listed Reporting Device - 2 - Trove Honeywell XBV Kits Installation Guide T2HWK78(D)V: Installation Instructions for Honeywell Access Controllers 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2a, pg. 3). 3. Mount backplane to enclosure with hardware. Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models: Honeywell Board Pem Mounting 3200 Series or WIN-PAK Series A PW6K1ICE or PW6K1R1E B Fig. 2 + DC - INTERFACE FACP BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + AlAtrlotrnoixni-xAALL1102042U4LXXBB22V AC DELAY L G N NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8(CB) 1 2 3 4 1 2 3 4 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control IN2 Fuse + INP1 -- + INP2 -- DM1 + OFF IN1 IN2 IN1 Fuse DM1 + Altronix - PDS8(CB) P Common (--- ) OUT1 DM2 + N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 Common (--- ) DM2 + Altronix VR6 is mounted under PDS8(CB) A B Trove Honeywell XBV Kits Installation Guide A B A A Fig. 2a Pem Spacer Pan Head Screw Honeywell Access Controller Backplane - 3 - T3HWK7516(D)V: Installation Instructions for Honeywell Access Controllers 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 3, pg. 4). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3a, pg. 4). 3. Mount backplane to enclosure with hardware. Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models: Honeywell Board Pem Mounting 3200 Series or WIN-PAK Series A PRO22MX8 B Fig. 3 A A + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + AAltlrtoronnixix-AALL11002244XUBL2XVB2 AC DELAY L G N - DC + RSB2 AC DC AlAtrltornoinxixA-L1A0L1120X1B22U2L0XB LG N BAT FAIL NC C NO NC C NO AC FAIL + BAT - INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8(CB) 1 2 3 4 1 2 3 4 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8(CB) 1 2 3 4 1 2 3 4 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control INPUT PN LED Altronix PD8UL R1 D1 B A A B A A 567 8 N COMMON POWER OUTPUTS FUSED POWER OUTPUTS 1 23 4 P Fig. 3a Pem Spacer Pan Head Screw Honeywell Access Controller Backplane - 4 - Trove Honeywell XBV Kits Installation Guide T3HWK7516(D)V: THWD2 (Door Backplane) Configuration of Honeywell ProWatch/WinPak Boards: Honeywell ProWatch/WinPak Access Controllers: 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 4, pg. 5). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 4a, pg. 5). 3. Mount backplane to enclosure with hardware. Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models: Honeywell Board 3200 Series or WIN-PAK Series PRO22MX8 Pem Mounting A B Fig. 4 A A B A A A Trove Honeywell XBV Kits Installation Guide A Fig. 4a Pem Spacer Pan Head Screw Honeywell Access Controller Backplane - 5 - Notes: - 6 - Trove Honeywell XBV Kits Installation Guide T2HWK78(D)V (Trove2) Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm) 2.00" (50.8mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Trove Honeywell XBV Kits Installation Guide - 7 - 2.00" (50.8mm) T3HWK7516(D)V (Trove3) Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm) 2.00" (50.8mm) 1.25" (31.8mm) 7.12" (222.3mm) 1" Conduit 3/4" Conduit 9.5" (241.3mm) 9.5" (241.3mm) 1.78" (45.2mm) 1.25" Conduit 1.5" Conduit 2" Conduit 1.5" Conduit 1.25" Conduit 1.55" (39.4mm) 1.25" (31.8mm) 1.07" (27.2mm) 30.12" (768.1mm) 14.01" (355.9mm) 14.01" (355.9mm) 2" (50.8mm) 1.10" (27.9mm) 1" Conduit 3/4" Conduit G G 1" Conduit 3/4" Conduit 10.75" (273.1mm) 10.75" (273.1mm) 10.62" (269.8mm) 36.12" (917.5mm) 33.63" (854.2mm) 10.62" (269.8mm) 10.75" (273.1mm) 10.75" (273.1mm) 3/4" Conduit 1" Conduit 1.25" (31.8mm) 2" 8.75" (222.3mm) (50.8mm) 8.62" (219mm) 8.75" (222.3mm) 7.06" (179.3mm) 1.25" (31.8mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove Honeywell XBV Kits A26W MEMBER - 8 - Trove Honeywell XBV Kits Installation Guide