Installation Guide for Altronix models including: T2HWK78V 8 Door Kit with Fused Outputs, T2HWK78V, 8 Door Kit with Fused Outputs, Kit with Fused Outputs, Fused Outputs

IITroveHW XBV Kits A26W

Installation Guide - Altronix

2 feb 2023 — T3HWK7516V. 16 Door Kit with Fused Outputs. Fully assembled kit includes: - Trove3 enclosure with THW3 Altronix/Honeywell backplane.

Click to View

Altronix T3HWK7516V | 16-Door Altronix/Honeywell Access and


File Info : application/pdf, 8 Pages, 1.02MB

PDF preview unavailable. Download the PDF instead.

Altronix-T3HWK7516DV-Trove3Hw3-16Dr-Ulx-Ptc-220-Installation-Instructions
Access & Power Integration

Altronix/Honeywell ProWatch/WinPak Kits

Models Include:

T2HWK78V
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with THW2 Altronix/Honeywell backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) ACM8 - Fused Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fused Power Distribution Module

T2HWK78DV
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with THW2 Altronix/Honeywell backplane - One (1) AL1024XB2V - Power Supply/Charger - One (1) ACM8CB - PTC Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8CB - Dual Input PTC Power Distribution Module

T3HWK7516V
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with THW3 Altronix/Honeywell backplane and THWD2 Honeywell door backplane
- One (1) AL1024XB2V - Power Supply/Charger - One (1) AL1012XB220 - Power Supply/Charger - Two (2) ACM8 - Fused Access Power Controllers - One (1) PD8UL - Fused Power Distribution Module - One (1) RSB2* - Rocker Switch Bracket with
Two (2) Rocker Switches

T3HWK7516DV
16 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove3 enclosure with THW3 Altronix/Honeywell backplane and THWD2 Honeywell door backplane
- One (1) AL1024XB2V - Power Supply/Charger - One (1) AL1012XB220 - Power Supply/Charger - Two (2) ACM8CB - PTC Access Power Controllers - One (1) PD8ULCB - PTC Power Distribution Module - One (1) RSB2* - Rocker Switch Bracket with
Two (2) Rocker Switches

Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. THWLKV_012623 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Altronix Trove Honeywell kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. All kits accommodate a variety of Honeywell modules for up to eight (T2HWK78(D)) or sixteen (T3HWK7516(D)) doors in a single enclosure.

Configuration Chart:

Additional Fused (PTC) Outputs ACM8(CB) Board Input Fuse Rating ACM8(CB) Board Output Fuse (PTC) Rating PDS8(CB) Board Input Fuse (PTC) Rating PDS8(CB) Board Output Fuse(PTC) Rating PD8UL(CB) Board Output Fuse (PTC) Rating

Altronix Model Number

Maximum Supply

Current for Main

Outputs on

Power Power Power Supply Nominal Fail-Safe/

220VAC Supply Supply

board

DC Fail-

60Hz Board Board and ACM8(CB) Output Secure

Input Input Battery Access Power Voltage or Dry

Current Fuse Fuse Controllers' Range Form "C"

(A) Rating Rating

outputs

(VDC) Outputs

T2HWK78V

2.5

15A/ 32V

24VDC @ 9.7A

20.1726.4

8

8

T2HWK78DV

5A/

T3HWK7516V 3.8
T3HWK7516DV

250V
15A/ 32V

24VDC @ 9.4A 12VDC @ 10A

20.1726.4
9.713.2

16

8

2.5A/ 10A/ 3A/ 10A/ 250V 32V 32V

­

250V 2.5A 9A 2.5A ­

2.5A/

10A/ 250V 250V

­

2.5A

3.5A/ ­ 250V
2.5A

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.

Product is intended for indoor use only.

1. Remove backplane from enclosure. Do not discard hardware.

If your application requires a raised backplane, re-mount it using metal spacers and screws (provided).

2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and

screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper screws; level and secure.

Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's

upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws.

3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in

Fig. 1

desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the

enclosure approximately 2" from the right side (Fig. 1, pg. 2).

Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.

Enclosure

4. Mount Honeywell modules to backplane(s), refer to pages 3, 4, 5. 5. Refer to the XBV Power Supply/Charger Installation Guide for AL1024XB2V and

Edge of Enclosure

AL1012XB220 and corresponding Sub-Assembly Installation Guides for ACM8(CB), PDS8(CB), VR6 and PD8UL(CB) for further installation instructions.

Tamper Switch (included)

Hardware:
Nylon Spacer |

5/16" Pan Head Screw | Lock Nut

To Access Control Panel or UL Listed Reporting Device

- 2 -

Trove Honeywell XBV Kits Installation Guide

T2HWK78(D)V: Installation Instructions for Honeywell Access Controllers 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 2, pg. 3). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2a, pg. 3). 3. Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models:

Honeywell Board

Pem Mounting

3200 Series or WIN-PAK Series

A

PW6K1ICE or PW6K1R1E

B

Fig. 2

+ DC -

INTERFACE

FACP

BAT FAIL NC C NO NC C NO AC FAIL
AC DC
- BAT +

AlAtrlotrnoixni-xAALL1102042U4LXXBB22V
AC DELAY

L G N

NO C NC +INP- T + RET-

TRIGGER INPUT

IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND

1

2

3

4

5

6

7

8

F1

F2

F3

F4

F5

F6

F7

F8

FACP TRG

ON

ON

Altronix - ACM8(CB) 1 2 3 4 1 2 3 4

MAIN 10A 250V

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4

OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

-+-+ Power Control

IN2 Fuse + INP1 -- + INP2 --

DM1 +

OFF

IN1

IN2

IN1 Fuse

DM1 +

Altronix - PDS8(CB)

P

Common (--- )

OUT1

DM2 +

N
1

OUT2 OUT3 OUT4

OUT5 OUT6 OUT7

2

3

4

5

6

7

Common Power Outputs (NEG)

OUT8 8

Common (--- ) DM2 +

Altronix VR6 is mounted under PDS8(CB)

A B

Trove Honeywell XBV Kits Installation Guide

A B
A

A

Fig. 2a

Pem Spacer

Pan Head Screw

Honeywell Access Controller

Backplane
- 3 -

T3HWK7516(D)V: Installation Instructions for Honeywell Access Controllers 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 3, pg. 4). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3a, pg. 4). 3. Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models:

Honeywell Board

Pem Mounting

3200 Series or WIN-PAK Series

A

PRO22MX8

B

Fig. 3

A

A

+ DC -

BAT FAIL NC C NO NC C NO AC FAIL
AC DC - BAT +

AAltlrtoronnixix-AALL11002244XUBL2XVB2
AC DELAY

L G N

- DC +

RSB2

AC DC
AlAtrltornoinxixA-L1A0L1120X1B22U2L0XB

LG N

BAT FAIL NC C NO NC C NO AC FAIL

+ BAT -

INTERFACE

NO C NC +INP- T + RET-

TRIGGER INPUT

IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND

1

2

3

4

5

6

7

8

F1

F2

F3

F4

F5

F6

F7

F8

FACP TRG

ON

ON

Altronix - ACM8(CB) 1 2 3 4 1 2 3 4

FACP

MAIN 10A 250V

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4

OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

-+-+ Power Control

INTERFACE

NO C NC +INP- T + RET-

TRIGGER INPUT

IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND

1

2

3

4

5

6

7

8

F1

F2

F3

F4

F5

F6

F7

F8

FACP TRG

ON

ON

Altronix - ACM8(CB) 1 2 3 4 1 2 3 4

FACP

MAIN 10A 250V

NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM

OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4

OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8

-+-+ Power Control

INPUT PN

LED

Altronix PD8UL

R1

D1

B A
A

B A
A

567 8

N COMMON POWER OUTPUTS

FUSED POWER OUTPUTS

1 23 4 P

Fig. 3a

Pem Spacer

Pan Head Screw

Honeywell Access Controller

Backplane

- 4 -

Trove Honeywell XBV Kits Installation Guide

T3HWK7516(D)V: THWD2 (Door Backplane) Configuration of Honeywell ProWatch/WinPak Boards: Honeywell ProWatch/WinPak Access Controllers: 1. Fasten spacers (provided) into pem configuration (A) or (B) of backplane (Fig. 4, pg. 5). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 4a, pg. 5). 3. Mount backplane to enclosure with hardware.

Honeywell ProWatch/WinPak Access Controller Position Chart for the Following Models:

Honeywell Board 3200 Series or WIN-PAK Series PRO22MX8

Pem Mounting A B

Fig. 4

A

A

B

A

A

A
Trove Honeywell XBV Kits Installation Guide

A

Fig. 4a

Pem Spacer

Pan Head Screw

Honeywell Access Controller

Backplane
- 5 -

Notes:

- 6 -

Trove Honeywell XBV Kits Installation Guide

T2HWK78(D)V (Trove2) Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm)

2.00" (50.8mm)

21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

Trove Honeywell XBV Kits Installation Guide

- 7 -

2.00" (50.8mm)

T3HWK7516(D)V (Trove3) Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm)

2.00" (50.8mm) 1.25" (31.8mm)

7.12" (222.3mm)
1" Conduit 3/4" Conduit

9.5" (241.3mm)

9.5" (241.3mm) 1.78" (45.2mm)

1.25" Conduit 1.5" Conduit

2" Conduit

1.5" Conduit 1.25" Conduit

1.55" (39.4mm)

1.25" (31.8mm)

1.07" (27.2mm)

30.12" (768.1mm) 14.01" (355.9mm)

14.01" (355.9mm)

2" (50.8mm)

1.10" (27.9mm)

1" Conduit 3/4" Conduit
G G

1" Conduit 3/4" Conduit

10.75" (273.1mm)

10.75" (273.1mm)

10.62" (269.8mm) 36.12" (917.5mm)

33.63" (854.2mm)

10.62" (269.8mm)

10.75" (273.1mm)

10.75" (273.1mm)

3/4" Conduit 1" Conduit

1.25" (31.8mm)

2"

8.75" (222.3mm)

(50.8mm)

8.62" (219mm)

8.75" (222.3mm)

7.06" (179.3mm)

1.25" (31.8mm)

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty

IITrove Honeywell XBV Kits

A26W

MEMBER

- 8 -

Trove Honeywell XBV Kits Installation Guide



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)