DIGI TM-B3SENSOR Smart Sense B3 Sensor
Use these instructions to add a SmartSense B3 Sensor to an existing SmartSense environment.
Kufunga Sensorer B3
Your SmartSense B3 Sensor arrives powered off.
- Hold the power button for 2-5 seconds, then release to turn on the B3 Sensor.
- Both the green and red LEDs will simultaneously blink twice to indicate the sensor is on and will report at a scheduled interval (under normal operation, these are the only times the LEDs will illuminate).
- To check the status of a B3 Sensor, press the power button once. A green LED indicates the sensor is on, while a red LED indicates that the sensor is in Hibernation Mode (not collecting or sending data).**
- SmartSense recommends installing the sensor according to the FDA Food Code, placing it “in a location that is representative of the actual storage temperature of the unit,” away from any compressors or fans.
- Tumia zip tie iliyojumuishwa ili kupachika Kihisi B3. Tai ya zipu inapaswa kuunganishwa kupitia kitanzi cha kupachika kilicho juu ya kitambuzi na kuunganishwa kwa usalama kwenye sehemu ya kupachika ili kitambuzi kining'inie wima na kikitazama mlango wa kipochi chako.
- If a suitable mounting point does not exist, contact SmartSense Support for additional mounting options.
Once turned on, the B3 Sensor may be placed back into Hibernation Mode if not in use. To place the sensor into Hibernation Mode, hold the power button down for about 5 seconds (until the green and red LEDs simultaneously blink 3 times), release the button, and hold the button again for 2-5 seconds within 20 seconds to confirm Hibernation Mode is activated (a single red LED flash will confirm the device is back in Hibernation Mode). You can press the power button again to confirm the B3 Sensor is in Hibernation Mode (the red LED will flash once).
Kumbuka
When you put the B3 Sensor in Hibernation Mode, the device cannot be re-enabled for one minute to allow for proper shutdown; all stored data will be deleted, and the device will revert to its default configuration.
Tahadhari
Risk of fire and burns. Do not recharge, disassemble, heat above (manufacturer’s specified temperature), or incinerate. Keep the battery out of reach of children and in its original package until ready to use. Dispose of used batteries promptly.
Thibitisha Kihisi cha B3 kinaripoti
Thibitisha kuwa kihisi cha B3 kinawasiliana na dashibodi yako ya SmartSense. Ikiwa huna kuingia kwa kutumia ruhusa za Msimamizi Mkuu au Msimamizi, mwombe mwenzako atekeleze ukaguzi huu. Utahitaji kuingia kwenye SmartSense Web Programu.
- Fungua a web browser and navigate to app.smartsense.co.
- Enter your credentials (username and password), then select LOG IN.
- At the top of the screen, click ADMI, N, then select SYSTEM MANAGEMENT.
- Click the UNASSIGNED SENSORS tab.
- Katika upau wa kutafutia, ingiza Kitambulisho cha Kifaa mbele ya kihisi cha B3 (Kitambulisho cha Kifaa kinaanza na "D6" na utafutaji unahitaji kitambulisho kamili cha sensor).
- When the B3 Sensor is communicating successfully, the LAST COMMUNICATION DATE column should display a recent date and time.
- This confirms that the B3 Sensor is communicating as expected.
Miongozo ya Ufungaji
- Ambient Sensor Installation
- SmartSense Sensor Hub User Guide
- Grocery Self-Installation Guide
- Kitchen Self-Installation Guide
- Warehouse Self-Installation Guide
- Hospital and Pharmacy Self-Installation Guide
- Glycol Probe Installation
- SmartSense
- SmartTemps
- Matoleo Mapya
- Trainings & FAQs
- Sensorer
- Milango
- Uchunguzi
- Ufungaji
- Urithi
- Elekeza upya au uhamishe tena antena inayopokea
- Ongeza utengano kati ya kifaa na mpokeaji
- Unganisha vifaa kwenye duka kwenye mzunguko tofauti na ile ambayo mpokeaji ameunganishwa
- Wasiliana na muuzaji au mtaalamu wa redio/TV kwa usaidizi
INAWEZA ICES-3 (B)/NMB-3 (B)
Kifaa hiki cha dijitali cha Daraja B kinatii ICES-003 ya Kanada.
Taarifa Isiyo ya Marekebisho
SmartSense by Digi has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment.
Taarifa ya Mfiduo wa RF
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between radiator and any part of your body. This equipment meets the exemption from the routine evaluation limits in section 2.5 of RSS-102. It should be installed and operated with a minimum distance of 20 cm between the radiator and any part of your body.
Antena
The B3 Sensor has been certified with a permanent, ceramic chip antenna installed on the internal circuit board. The max peak gain tested was 2.93dBi.
The following chip antennas have been considered:
- Johanson part number 2450AT18B100
- PSA-Walsin part number RFANT3216120A5T
Nyaraka / Rasilimali
![]() |
DIGI TM-B3SENSOR Smart Sense B3 Sensor [pdf] Mwongozo wa Mmiliki 2ATZ3-B3SENSOR, 2ATZ3B3SENSOR, TM-B3SENSOR Smart Sense B3 Sensor, TM-B3SENSOR, Smart Sense B3 Sensor, Sense B3 Sensor, B3 Sensor, Sensor |