Manuali i përdorimit të softuerit të rrjetit OpenRAN Parallel Wireless DRRU-R428

DRRU-R428 OpenRAN Software Network

Manuali i përdorimit DRRU-R428

përmbajtja

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

1. Konfigurimi i radios ……………………………………………………………………………………………………………………………………………………………………………………………… 3 1.1. Ndërfaqja e radios …………………………………………………………………………………………………………………………………………………………………………………………………..3 1.2. Lidhja tipike………………………………………………………………………………………………………………………………………………………………………………………….5 2. Hyrja në radio ………………………………………………………………………………………………………………………………………………………………………………………. 6 2.1. Aktivizo GUI me derën e pasme………………………………………………………………………………………………………………………………………………………6 2.2. Identifikohu OMT …………………………………………………………………………………………………………………………………………………………………………………………….. 7 2.3. Identifikimi i konsolës ………………………………………………………………………………………………………………………………………………………………………………… 7 3. Përmirëso …………………………………………………………………………………………………………………………………………………………………………………………………. 8 3.1. Kontrolli i versionit të firmuerit……………………………………………………………………………………………………………………………………………………………..8 3.2. Përmirësimi me një ngarkesë të re……………………………………………………………………………………………………………………………………………………………9 3.3. Konfigurimi i ngarkesës (nëse nevojitet) ……………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………. 10 4. Konfigurimi i bartësit …………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………11 4.1. Faktori i Konvertimit të Fuqisë ………………………………………………………………………………………………………………………………………………………….. 11 4.2. Konfigurimi eAxC …………………………………………………………………………………………………………………………………………………………………………….. 11 4.3. Gjerësia e brezit dhe frekuenca qendrore …………………………………………………………………………………………………………………………………………………………………… 13 4.4. Aktivizo operatorin……………………………………………………………………………………………………………………………………………………………………………………………14 4.5. Adresa e DU MAC-it……………………………………………………………………………………………………………………………………………………………………………………14 4.6. ID-ja e VLAN-it të CUS-Aeroplanit………………………………………………………………………………………………………………………………………………………………….. 15 4.7. Qasja në regjistër ………………………………………………………………………………………………………………………………………………………………………………………… 15 4.8. Konsideratat e transportuesit të dyfishtë…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………… 16 5. Monitorimi i statusit …………………………………………………………………………………………………………………………………………………………………..18 5.1. Monitoruesi i statusit të PTP ………………………………………………………………………………………………………………………………………………………………………………………… 18 5.2. Monitori i fuqisë……………………………………………………………………………………………………………………………………………………………………………………….18 5.3. Numëruesit ……………………………………………………………………………………………………………………………………………………………………………………………………. 19 6. Mjetet e mirëmbajtjes ……………………………………………………………………………………………………………………………………………………………………………………..20 6.1. Pajisjet e rivendosjes manuale………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………. 20 6.2. Rivendosja e skadimit të MPLANE…………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………… 20

© Manuali i Përdoruesit CrossFire X2RU | 2 nga 21

1. Konfigurimi i radios
1.1. Ndërfaqja e radios
Ju lutemi gjeni Tabelën 3-1 për përkufizimet e ndërfaqes të paraqitura në figurën më poshtë:
6

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

7

1

2

3

4

5
8 9 10 11

12

© Manuali i Përdoruesit CrossFire X2RU | 3 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

Numri i indeksit

Emri i portit

Tabela 1-1 Përkufizimi i ndërfaqes Përshkrimi

1

CH1

Porta 1 e dyfishtë DL/UL RF

2

CH2

Porta 2 e dyfishtë DL/UL RF

3

CH3

Porta 3 e dyfishtë DL/UL RF

4

CH4

Porta 4 e dyfishtë DL/UL RF

5

ALARM

Porta e alarmit të jashtëm

6

PUSHTETI

Ndërfaqja e prizës së energjisë

7

RET

Rezervuar

8

GND

Tokëzimi

9

DEBUGON

Ndërfaqja e mirëmbajtjes

10

OPS

Porta OP për njësinë e mëparshme

11

ZKM

Porta OP e rezervuar për Cascade

12

LED

Treguesi LED i OP & System

* Ju lutemi përdorni portën 10G dhe modulin SFP+

Vërejtje Lidhu me antenën
GUI: https://10.7.3.200 e paracaktuar Lidhu me ndërprerësin DU/PTP

Shihni statusin e treguesit dhe treguesit në tabelën e mëposhtme:

Treguesi optik Jeshile Kuqe N/A

Tabela 1-2 TREGUESI OPTIK OPS/OPM Përshkrimi Normal Lidhja optike nuk është e sinkronizuar. Moduli optik nuk është i lidhur

Treguesi i statusit Blic i gjelbër i ngurtë Blic i kuq i kuq i ngurtë Portokalli Portokalli i ngurtë

Përshkrimi

Tabela 1-3 TREGUESI I EKZEKUTIMIT TË SISTEMIT

Elementi punon pa alarm

Softueri është rrëzuar, por do të rindizet automatikisht pas 3 minutash

Elementi është duke punuar por me alarm

Softueri është rrëzuar (me alarm), por do të rindizet automatikisht në 3 minuta

Softueri është duke u përmirësuar

Elementi po nis

© Manuali i Përdoruesit CrossFire X2RU | 4 nga 21

1.2. Lidhje tipike
Figura më poshtë tregon lidhjen tipike të X2RU në një aplikacion ORAN.

DU

X2RU

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
Sistemi i antenës MIMO 4×4

Antenë GPS

Mjeshtër i madh

Ndërprerës PTP

Shënim: Ju lutemi përdorni portën 10G dhe modulin SFP+ për DU dhe X2RU.

Lloji FTLX8573D3BTL

Rekomandim SFP+:

Debug PC
Statusi u vërtetua

© Manuali i Përdoruesit CrossFire X2RU | 5 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
2. Hyrja në radio
Aktualisht X2RU përdor portën Ethernet të korrigjimit lokal për radio O&M. Ai përdor një adresë IP fikse prej 10.7.3.200. Për t'u identifikuar në radio, ju lutemi konfirmoni që adresa IP e PC-së është e aksesueshme për radion. Fotografia më poshtë tregon një ishample.
2.1. Aktivizo GUI me derën e pasme
Për versionin më të fundit, GUI do të çaktivizohet për konsiderata sigurie, të gjitha konfigurimet do të shtyhen nga M-Plane. Në këtë rast, është shumë e papërshtatshme për radio IOT dhe korrigjimin e gabimeve. Një derë e pasme mund të përdoret për të aktivizuar GUI, ju lutemi ndiqni hapat e mëposhtëm për këtë funksion:
Hapi # 1 – Hap konsolën e komandës së Windows dhe përdor komandën: ssh dasUser@10.7.3.200
Hapi #2 – Futni fjalëkalimin: CF!DasUser@sw1
Hapi #3 – Përdorni komandën blow në tastierë: prekni /tmp/boa.txt
Hapi # 4 - Prisni 3 minuta për të marrë autoritetin GUI
© Manuali i Përdoruesit CrossFire X2RU | 6 nga 21

2.2. Identifikohu OMT
Ju lutemi shkruani https://10.7.3.200 në një shfletues interneti për të vizituar web GUI.

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

Në faqen e hyrjes, përdorni kredencialet e treguara më poshtë: Përdorues
Fjalëkalimi

admin admin

2.3. Identifikimi i konsolës
Në integrimin aktual stage, ndonjëherë do të kërkonte qasje në konsolë për të korrigjuar ose monitoruar radion. Ju lutemi, përdorni çdo mjet SSH për t'u identifikuar në tastierën e radios nëpërmjet dasUser@10.7.3.200.
Fjalëkalimi: CF!DasUser@sw1 Hyrja mund të refuzohet për herë të parë, ju lutemi provoni përsëri me kredencialin.

© Manuali i Përdoruesit CrossFire X2RU | 7 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
3. Përmirëso
3.1. Kontrolli i versionit të firmuerit
Informacioni i versionit të firmuerit gjendet në faqen Mirëmbajtja -> Inxhinieri dhe Cilësimet > Lidhshmëria LAN, mund të ndiqni treguesin e kuq të paraqitur në fotot më poshtë. 1) Merrni programin e mëposhtëm të firmuerit si një shembullampLe, numri i versionit tregohet në imazhin e mëposhtëm:
Versioni i softuerit 2) Shtypni paketën e programit të firmuerit për të parë numrat e versioneve dhe CRC të programeve të tjera, si ARM, PA dhe SETUP_NETCONF.
Kontrolli i CRC-së i aplikacionit M-plane Kontrolli i ARM CRC
Versioni i vendosjes së Netconf Versioni FPGA
FileVersioni i sistemit
3) Numri i versionit dhe CRC (~) në programin e mësipërm të firmuerit mund të korrespondojnë me ekranin në OMT një nga një, siç tregohet në figurat e mëposhtme:
© Manuali i Përdoruesit CrossFire X2RU | 8 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
Pastaj klikoni në butonin "Pyetje të gjitha" të paraqitur në foto me shenjë blu. Informacioni CRC për firmuerin aktualisht në përdorim do të shfaqet në kutinë e shënuar me të kuqe. Shënim që në figurën e mëposhtme tregoni informacionin e firmuerit të pajisjes aktuale. Mund të krahasoni informacionin e firmuerit me paketën e softuerit për të kontrolluar nëse firmware është i përditësuar ose për të konfirmuar rezultatin e përmirësimit.
3.2. Përmirëso me një ngarkesë të re
Klikoni në butonin Upgrade që shfaqet në faqen kryesore më poshtë.

Pasi të hyni në faqen e azhurnimit, klikoni në butonin "Ngarko" të paraqitur më poshtë; a file do të kërkohet, zgjidhni paketën për të përmirësuar radion. Pasi të jetë zgjedhur dhe ngarkuar paketa, zgjidhni firmuerin që do të përmirësohet sipas Hapit dhe klikoni "përmirësim i detyruar" për të përmirësuar firmuerin.
Një paralajmërim do të shfaqet siç tregohet më poshtë, klikoni butonin OK.
Më pas do t'ju kërkohet një fjalëkalim për "Përmirësimin me forcë", shkruani "iDas" dhe konfirmoni.
© Manuali i Përdoruesit CrossFire X2RU | 9 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06 dBm Kur shihni mesazhin e treguar më poshtë, përmirësimi ka përfunduar dhe radioja do të rindizet. Ju lutemi prisni derisa radio të fillojë të funksionojë me firmware-in e ri.
3.3. Konfigurimi i ngarkimit (nëse nevojitet)
Klikoni në butonin Konfigurimi –> Konfigurimi i ngarkimit i paraqitur në faqen kryesore më poshtë; Klikoni në butonin e ngarkimit për të ngarkuar konfigurimin file;
Nëse ngarkohet me sukses sssssssss, do të ketë një dritare të shpejtë.
© Manuali i Përdoruesit CrossFire X2RU | 10 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

4. Konfigurimi i transportuesit

4.1. Faktori i Konvertimit të Fuqisë

Fuqia e pritshme e hyrjes DL Digital IQ në RU në dBFS për fuqinë dalëse të vlerësuara maksimale TX në portën e antenës. RE ave Fuqia (dBFS)-13.7

4.2. Konfigurimi eAxC

Konfigurimi eAxC është i paracaktuar siç tregohet më poshtë:
Sta-LLRE-C00-P00-0 (RXA0P00C00)
Sta-LLRE-C00-P00-1 (PRACHA0P00C00)
Sta-LLRE-C00-P01-0 (RXA0P01C00)
Sta-LLRE-C00-P01-1 (PRACHA0P01C00)
Sta-LLRE-C00-P02-0 (RXA0P02C00)
Sta-LLRE-C00-P02-1 (PRACHA0P02C00)
Sta-LLRE-C00-P03-0 (RXA0P03C00)
Sta-LLRE-C00-P03-1 (PRACHA0P03C00)
Sta-LLRE-C01-P00-0 (RXA0P00C01)
Sta-LLRE-C01-P00-1 (PRACHA0P00C01)
Sta-LLRE-C01-P01-0 (RXA0P01C01)
Sta-LLRE-C01-P01-1 (PRACHA0P01C01)
Sta-LLRE-C01-P02-0 (RXA0P02C01)
Sta-LLRE-C01-P02-1 (PRACHA0P02C01)
Sta-LLRE-C01-P03-0 (RXA0P03C01)
Sta-LLRE-C01-P03-1 (PRACHA0P03C01)

LLRE-C00-P00-0(RXA0P00C00) EAXCID=0000 0000 0000 0000
LLRE-C00-P00-1(PRACHA0P00C00) EAXCID=0000 0000 0000 1000
LLRE-C00-P01-0(RXA0P01C00) EAXCID=0000 0000 0000 0001
LLRE-C00-P01-1(PRACHA0P01C00) EAXCID=0000 0000 0000 1001
LLRE-C00-P02-0(RXA0P02C00) EAXCID=0000 0000 0000 0010
LLRE-C00-P02-1(PRACHA0P02C00) EAXCID=0000 0000 0000 1010
LLRE-C00-P03-0(RXA0P03C00) EAXCID=0000 0000 0000 0011
LLRE-C00-P03-1(PRACHA0P03C00) EAXCID=0000 0000 0000 1011
LLRE-C01-P00-0(RXA0P00C01) EAXCID=0000 0000 0001 0000
LLRE-C01-P00-1(PRACHA0P00C01) EAXCID=0000 0000 0001 1000
LLRE-C01-P01-0(RXA0P01C01) EAXCID=0000 0000 0001 0001
LLRE-C01-P01-1(PRACHA0P01C01) EAXCID=0000 0000 0001 1001
LLRE-C01-P02-0(RXA0P02C01) EAXCID=0000 0000 0001 0010
LLRE-C01-P02-1(PRACHA0P02C01) EAXCID=0000 0000 0001 1010
LLRE-C01-P03-0(RXA0P03C01) EAXCID=0000 0000 0001 0011
LLRE-C01-P03-1(PRACHA0P03C01) EAXCID=0000 0000 0001 1011

LLRL0 (RXA0P00C00)
LLRL1 (PRACHA0P00C00)
LLRL2 (RXA0P01C00)
LLRL3 (PRACHA0P01C00)
LLRL4 (RXA0P02C00)
LLRL5 (PRACHA0P02C00)
LLRL6 (RXA0P03C00)
LLRL7 (PRACHA0P03C00)
LLRL8 (RXA0P00C01)
LLRL9 (PRACHA0P00C01)
LLRL10 (RXA0P01C01)
LLRL11 (PRACHA0P01C01)
LLRL12 (RXA0P02C01)
LLRL13 (PRACHA0P02C01)
LLRL14 (RXA0P03C01)
LLRL15 (PRACHA0P03C01)

RXArray0 (RXArray0)

Porta FH e ndërfaqes Itef (ETH1)
Sta-LLRE-C02-P00-0 (RXA0P00C02)
Sta-LLRE-C02-P00-1 (PRACHA0P00C02)
Sta-LLRE-C02-P01-0 (RXA0P01C02)
Sta-LLRE-C02-P01-1 (PRACHA0P01C02)
Sta-LLRE-C02-P02-0 (RXA0P02C02)
Sta-LLRE-C02-P02-1 (PRACHA0P02C02)
Sta-LLRE-C02-P03-0 (RXA0P03C02)
Sta-LLRE-C02-P03-1 (PRACHA0P03C02)
Sta-LLRE-C03-P00-0 (RXA0P00C03)
Sta-LLRE-C03-P00-1 (PRACHA0P00C03)
Sta-LLRE-C03-P01-0 (RXA0P01C03)
Sta-LLRE-C03-P01-1 (PRACHA0P01C03)
Sta-LLRE-C03-P02-0 (RXA0P02C03)
Sta-LLRE-C03-P02-1 (PRACHA0P02C03)
Sta-LLRE-C03-P03-0 (RXA0P03C03)
Sta-LLRE-C03-P03-1 (PRACHA0P03C03)

Elementi i përpunimit (PE0)
LLRE-C02-P00-0(RXA0P00C02) EAXCID=0000 0000 0002 0000
LLRE-C02-P00-1(PRACHA0P00C02) EAXCID=0000 0000 0002 1000
LLRE-C02-P01-0(RXA0P01C02) EAXCID=0000 0000 0002 0001
LLRE-C02-P01-1(PRACHA0P01C02) EAXCID=0000 0000 0002 1001
LLRE-C02-P02-0(RXA0P02C02) EAXCID=0000 0000 0002 0010
LLRE-C02-P02-1(PRACHA0P02C02) EAXCID=0000 0000 0002 1010
LLRE-C02-P03-0(RXA0P03C02) EAXCID=0000 0000 0002 0011
LLRE-C02-P03-1(PRACHA0P03C02) EAXCID=0000 0000 0002 1011
LLRE-C03-P00-0(RXA0P00C03) EAXCID=0000 0000 0003 0000
LLRE-C03-P00-1(PRACHA0P00C03) EAXCID=0000 0000 0003 1000
LLRE-C03-P01-0(RXA0P01C03) EAXCID=0000 0000 0003 0001
LLRE-C03-P01-1(PRACHA0P01C03) EAXCID=0000 0000 0003 1001
LLRE-C03-P02-0(RXA0P02C03) EAXCID=0000 0000 0003 0010
LLRE-C03-P02-1(PRACHA0P02C03) EAXCID=0000 0000 0003 1010
LLRE-C03-P03-0(RXA0P03C03) EAXCID=0000 0000 0003 0011
LLRE-C03-P03-1(PRACHA0P03C03) EAXCID=0000 0000 0003 1011

LLRL0 (RXA0P00C02)
LLRL1 (PRACHA0P00C02)
LLRL2 (RXA0P01C02)
LLRL3 (PRACHA0P01C02)
LLRL4 (RXA0P02C02)
LLRL5 (PRACHA0P02C02)
LLRL6 (RXA0P03C02)
LLRL7 (PRACHA0P03C02)
LLRL8 (RXA0P00C03)
LLRL9 (PRACHA0P00C03)
LLRL10 (RXA0P01C03)
LLRL11 (PRACHA0P01C03)
LLRL12 (RXA0P02C03)
LLRL13 (PRACHA0P02C03)
LLRL14 (RXA0P03C03)
LLRL15 (PRACHA0P03C03)

RX-Arra y-Carrier0 (RXA0CC00)
RX-Arra y-Carrier1 (RXA0CC01)
RX-Arra y-Carrier2 (RXA0CC02)
RX-Arra y-Carrier1 (RXA0CC03)

© Manuali i Përdoruesit CrossFire X2RU | 11 nga 21

TXArray0 (TXArray0)

Sta-LLTE-C00-P00-0 (TXA0P00C00)
Sta-LLTE-C00-P01-0 (TXA0P01C00)
Sta-LLTE-C00-P02-0 (TXA0P02C00)
Sta-LLTE-C00-P03-0 (TXA0P03C00)
Sta-LLTE-C01-P00-0 (TXA0P00C01)
Sta-LLTE-C01-P01-0 (TXA0P01C01)
Sta-LLTE-C01-P02-0 (TXA0P02C01)
Sta-LLTE-C01-P03-0 (TXA0P03C01)
Porta FH e ndërfaqes Itef (ETH1)

LLTE-C00-P00-0(TXA0P00C00) EAXCID=0000 0000 0000 0000
LLTE-C00-P01-0(TXA0P01C00) EAXCID=0000 0000 0000 0001
LLTE-C00-P02-0(TXA0P02C00) EAXCID=0000 0000 0000 0010
LLTE-C00-P03-0(TXA0P03C00) EAXCID=0000 0000 0000 0011
LLTE-C01-P00-0(TXA0P01C00) EAXCID=0000 0000 0001 0000
LLTE-C01-P01-0(TXA0P01C01) EAXCID=0000 0000 0001 0001
LLTE-C01-P02-0(TXA0P02C01) EAXCID=0000 0000 0001 0010
LLTE-C01-P03-0(TXA0P03C01) EAXCID=0000 0000 0001 0011
Elementi i përpunimit (PE0)

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
LLTL0 (TXA0P00C00)

LLTL1 (TXA0P01C00)
LLTL2 (TXA0P02C00)

TX-Array-Carrier0 (TXA0CC00)

LLTL3 (TXA0P03C00)

LLTL4 (TXA0P00C01)
LLTL5 (TXA0P01C01)
LLTL6 (TXA0P02C01)
LLTL7 (TXA0P03C01)

TX-Array-Carrier1 (TXA0CC01)

Sta-LLTE-C02-P00-0 (TXA0P00C02)
Sta-LLTE-C02-P01-0 (TXA0P01C02)

LLTE-C02-P00-0(TXA0P00C02) EAXCID=0000 0000 0002 0000
LLTE-C02-P01-0(TXA0P01C02) EAXCID=0000 0000 0002 0001

LLTL0 (TXA0P00C02)
LLTL1 (TXA0P01C02)

Sta-LLTE-C02-P02-0 (TXA0P02C02)
Sta-LLTE-C02-P03-0 (TXA0P03C02)

LLTE-C02-P02-0(TXA0P02C02) EAXCID=0000 0000 0002 0010
LLTE-C02-P03-0(TXA0P03C02) EAXCID=0000 0000 0002 0011

LLTL2 (TXA0P02C02)
LLTL3 (TXA0P03C02)

Sta-LLTE-C03-P00-0 (TXA0P00C03)
Sta-LLTE-C03-P01-0 (TXA0P01C03)

LLTE-C03-P00-0(TXA0P01C00) EAXCID=0000 0000 0003 0000
LLTE-C03-P01-0(TXA0P01C03) EAXCID=0000 0000 0003 0001

LLTL4 (TXA0P00C03)
LLTL5 (TXA0P01C03)

Sta-LLTE-C03-P02-0 (TXA0P02C03)

LLTE-C03-P02-0(TXA0P02C03) EAXCID=0000 0000 0003 0010

LLTL6 (TXA0P02C03)

Sta-LLTE-C03-P03-0 (TXA0P03C03)

LLTE-C03-P03-0(TXA0P03C03) EAXCID=0000 0000 0003 0011

LLTL7 (TXA0P03C03)

Ndërsa ka ende disa parametra aktualisht duhet të konfigurohen edhe pse web OMT.

TX-Array-Carrier2 (TXA0CC02)
TX-Array-Carrier3 (TXA0CC03)

© Manuali i Përdoruesit CrossFire X2RU | 12 nga 21

4.3. Gjerësia e brezit dhe frekuenca qendrore
Konfigurimi i operatorit mund të gjendet në faqen "Cilësimet -> Informacioni i operatorit".

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

Mund të gjeni të njëjtin model të cilësimeve të operatorit për C0, C1, C2 dhe C3, këtu ne marrim C0 si një ishample. Frekuenca
Ju lutemi përdorni ARFCN të operatorit celular në vend të frekuencës qendrore për GUI. Pasi të vendoset ARFCN, informacioni i frekuencës mund të konfirmohet në seksionin e informacionit të transportuesit, siç tregohet në kutitë e numëruara dhe në figurën e mësipërme. Gjerësia e brezit Gjerësia e brezit për operatorin përkatës, Gjerësia e brezit është e zgjidhshme midis 5M/10M/15M/20M. Fitimi DL Pajisja mund të sintonizojë fuqinë dalëse të lidhjes së pajisjes duke konfiguruar parametrin DL Gain. Nëse transportuesi nuk përdoret, ju lutemi vendosni këtë vlerë në -50. Algoritmi i llogaritjes:
Fuqia dalëse e antenës = DL_Max_Fuqia(C0) + DL_Max_Fuqia(C1) + DL_Max_Fuqia(C2) + DL_Max_Fuqia(C3) ;
DL_Max_Power(Cn) = 46 dBm + (DL Gain(Cn) 58 dB) , (n = 0~1) ; Fuqia e vlerësuar e daljes së antenës = 46 dBm; Fitimi i vlerësuar DL = 58 dB;
© Manuali i Përdoruesit CrossFire X2RU | 13 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

CC Num 1 1 2 2 3 3 4 4

CC 0 DL Gain/dB 58 55 55 52 53 50 52 49

CC 1 DL Gain/dB -50 -50 55 52 53 50 52 49

CC 2 DL Gain/dB -50 -50 -50 -50 53 50 52 49

CC 3 DL Gain/dB -50 -50 -50 -50 -50 -50 52 49

Fuqia dalëse e antenës /dBm 46 43 46 43 46 43 46 43

UL Gain Correction Ju lutemi vendoseni në 0 për këtë version. Nuk përdoret aktualisht. Ju lutemi konfirmoni statusin e kutisë së kontrollit për parametrat përpara se të klikohet 'Set', përndryshe nuk do të zbatohet. Pasi të vendoset informacioni i operatorit, butoni i përditësimit duhet të klikohet për të aplikuar modifikimin, ai ndodhet në fund të GUI-së. Butoni i përditësimit do të bëhet i gjelbër pas klikimit, nëse butoni bëhet i kuq, tregon se është zbuluar gabim në cilësimet e operatorit.

4.4. Aktivizo operatorin

Transportuesit mund të aktivizohen dhe kyçen duke futur AKTIVE ose INACTIVE në fushën e treguar më sipër. Nëse transportuesi nuk përdoret, ju lutemi vendoseni në INACTIVE. Përditësimi duhet të klikohet për të aplikuar pasi këto parametra të ndryshojnë.
4.5. Adresa DU MAC
Adresa DU MAC mund të vendoset në faqen GUI Setting -> LAN Connectivity.

© Manuali i Përdoruesit CrossFire X2RU | 14 nga 21

4.6. CUS-Plane VLAN ID
ID-ja e VLAN-it CUS-Plane mund të caktohet në faqen GUI Setting ->Lidhshmëria LAN.

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

4.7. Qasja e regjistrimit

Hapi #1 Hyni në modalitetin e fabrikës (ju lutemi referojuni seksionit 4.6). Hapi #2 Hyni në faqen "Moduli Dixhital -> Ndërfaqja e Adresës". Hapi #3 Zgjidhni 'FPGA' për fushën "Zgjidhja e çipit". Hapi #4 Fut adresën e regjistrimit, gjatësinë (gjithmonë e caktuar në 4) . Hapi #5 Klikoni 'Query' për vlerën aktuale të treguar në fushën e Përmbajtjes dhe 'Set' për të aplikuar vlerën e re pas modifikimit.
© Manuali i Përdoruesit CrossFire X2RU | 15 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

4.8. Konsideratat e transportuesit të dyfishtë
Disa konsiderata shtesë nevojiten kur përdoren 2 transportues: 1) Frekuenca Kur përdoren 2 transportues, cilësimet e frekuencës në GUI janë të pavarura për dy transportuesit. Por duhet pasur kujdes i veçantë për të shmangur mbivendosjen e bartësve.
Frekuenca(ARFCN1) Frekuenca(ARFCN0) >= (Bw0 + Bw1) /2

cc0

cc1

bw0

bw1

ARFCN 0

ARFCN 1

Për cilësimet e frekuencës, ju lutemi gjeni parametrat e paraqitur në foton e mëposhtme:

© Manuali i Përdoruesit CrossFire X2RU | 16 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm 2) Cilësimet e fitimit Pajisja mund të përcaktojë fuqinë dalëse të lidhjes zbritëse të pajisjes duke konfiguruar parametrin DL Gain në OMT. Merrni C0
transportues si ishampLe, marrëdhënia korresponduese midis fuqisë dalëse të lidhjes së poshtme dhe fitimit DL tregohet si më poshtë: 46 dBm + ( Fitimi DL(C0) 58 dB ) = Fuqia maksimale DL (C0)
Shënim: 58dB është fitimi i vlerësuar i pajisjes dhe 46dBm është fuqia e vlerësuar e prodhimit në rrjedhën e poshtme të pajisjes. Kur përdoren 2 transportues, për DL 2 transportues do të ndajnë fuqinë nominale të daljes prej 46 dBm.
Kufizimi është: Max_Power(C0) + Max_Power(C1) <= 46 dbm
Ju mund të ndryshoni cilësimet e fitimit të DL për operatorin 0 dhe 1 për të përmbushur ekuacionin e treguar më sipër. Për të kërkuar DL Max Power, ju lutemi gjeni seksionin më poshtë në faqen e konfigurimit të operatorit.
Me konfigurime të sakta, informacioni i modulit do të tregohet i vlefshëm në pyetje pasi të klikohet butoni "Përditëso".
© Manuali i Përdoruesit CrossFire X2RU | 17 nga 21

5. Monitorimi i statusit
5.1. Monitorimi i statusit PTP
1) Statusi PTP

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

Statusi PTP mund të gjendet në faqen Cilësimet -> Informacioni i sinjalit të radios, drita jeshile tregon status të mirë PTP.
5.2. Monitor i fuqisë
1) Fuqia e antenës Fuqia hyrëse/dalëse e antenës mund të gjendet në faqen “Cilësimet -> Informacioni i sinjalit të radios”.
2) Fuqia e brezit bazë të antenës Fuqia e brezit bazë të antenës që transmetohet/merret në antenë mund të kontrollohet nga GUI në faqen Cilësimet -> Informacioni i sinjalit të radios. Fuqia e brezit bazë tregohet në dBm.

© Manuali i Përdoruesit CrossFire X2RU | 18 nga 21

3) Fuqia e transportuesit Fuqia e transportuesit mund të gjendet në faqen "Cilësimet -> Informacioni i transmetimit".

FUQIA E JASHTME
Fuqia dalëse 62.06dBm

Figura e mësipërme tregon fuqinë e brezit bazë UL/DL të bartësit0 në dBm.
5.3. Numëruesit
1) Numëruesit eCPRI Numri i paketave U-plane dhe paketave C-plane mund të monitorohen në faqen GUI Maintenance -> Engineering.

© Manuali i Përdoruesit CrossFire X2RU | 19 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
6. Mjetet e Mirëmbajtjes
6.1. Pajisjet e rivendosjes manuale
Pajisja mbështet rivendosjen manuale në OMT, mund të gjeni butonin e rivendosjes së harduerit në faqen GUI Mirëmbajtja -> Inxhinieri.
6.2. Rivendosja e skadimit të MPLANE
1) Nëse butoni MPLANE Timeout Reset aktivizohet Brenda 24 orëve pas fillimit të pajisjes, nëse platforma CMS nuk është lidhur me sukses, pajisja do të rivendoset në mënyrë aktive në një interval ore. Nëse CMS lidhet me sukses një herë dhe nuk kryhet asnjë operacion i rivendosjes, CMS ndalon zbulimin e lidhjes dhe nuk aktivizon mekanizmin e rivendosjes automatike 24-orëshe.
2) Nëse butoni MPLANE Timeout Reset është i çaktivizuar Pajisja nuk zbulon lidhjen me platformën CMS dhe nuk e rivendos pajisjen. Prandaj, nëse pajisja po korrigjohet, ju këshillojmë të çaktivizoni ndërprerësin.
© Manuali i Përdoruesit CrossFire X2RU | 20 nga 21

FUQIA E JASHTME
Fuqia dalëse 62.06dBm
FCC Paralajmërim: Kjo pajisje duhet të instalohet në mënyrë profesionale.
Ju lutemi, kini parasysh që ndryshimet ose modifikimet që nuk janë miratuar shprehimisht nga pala përgjegjëse për pajtueshmërinë mund të anulojnë autoritetin e përdoruesit për të përdorur pajisjen. Kjo pajisje përputhet me Pjesën 15 të Rregullave të FCC. Funksionimi i nënshtrohet dy kushteve të mëposhtme: (1) Kjo pajisje nuk mund të shkaktojë ndërhyrje të dëmshme dhe (2) Kjo pajisje duhet të pranojë çdo ndërhyrje të marrë, duke përfshirë ndërhyrjen që mund të shkaktojë funksionim të padëshiruar. Kjo pajisje përputhet me kufijtë e ekspozimit ndaj rrezatimit FCC të përcaktuara për një mjedis të pakontrolluar. Kjo pajisje duhet të instalohet dhe të përdoret me një distancë minimale 358.5 cm ndërmjet radiatorit dhe trupit tuaj.
SHËNIM: Vetëm personat e autorizuar mund të hyjnë në zonën ku është instaluar antena. Dhe personi është plotësisht i vetëdijshëm për potencialin e ekspozimit dhe mund të ushtrojë kontroll mbi ekspozimin e tij ose të saj duke u larguar nga zona ose me ndonjë mjet tjetër të përshtatshëm. Ndërgjegjësimi për potencialin e ekspozimit ndaj RF në një vend pune ose mjedis të ngjashëm mund të sigurohet përmes trajnimit specifik si pjesë e një programi sigurie RF.
© Manuali i Përdoruesit CrossFire X2RU | 21 nga 21

Dokumentet / Burimet

Softueri i rrjetit me valë paralele DRRU-R428 OpenRAN [pdf] Manuali i Përdoruesit
R42841, 2AI7FR42841, DRRU-R428 OpenRAN Network Software, DRRU-R428, OpenRAN Network Software, Network Software, Software

Referencat

Lini një koment

Adresa juaj e emailit nuk do të publikohet. Fushat e kërkuara janë shënuar *