DRRU-R428 OpenRAN Software di rete
DRRU-R428 Manuale d'uso
Cuntinutu
POTENZA EXTRA
62.06dBm di putenza di uscita
1. Installazione di a radio ………………………………………………………………………………………………………………………… ………………………………………… 3 1.1. Interfaccia radio …………………………………………………………………………………………………………………………………………………… …………………………………………..3 1.2. Cunnessione tipica …………………………………………………………………………………………………………………………………………………… ……………………………………………….5 2. Login Radio ………………………………………………………………………………… …………………………………………………………………………………. 6 2.1. Abilita GUI cù a porta di daretu ………………………………………………………………………………………………………………………… …………………………… 6 2.2. Login OMT …………………………………………………………………………………………………………………………………………………… ……………………………………………………….. 7 2.3. Login à la console ……………………………………………………………………………………………………………………………………… ……………………………………………………… 7 3. Avanzate …………………………………………………………………………………… ……………………………………………………………………………………………. 8 3.1. Verificazione di a versione di u firmware ……………………………………………………………………………………………………………………………………… ……………………………..8 3.2. Avanzate cù una nova carica……………………………………………………………………………………………………………………… ………………………………………… 9 3.3. Configurazione di Carica (Se Necessariu) ………………………………………………………………………………………………………………………… ……………………. 10 4. Cunfigurazione di u trasportatore ………………………………………………………………………………………………………………………… ……………………………11 4.1. Fattore di cunversione di putenza ……………………………………………………………………………………………………………………………………… …………………………….. 11 4.2. Configurazione eAxC ……………………………………………………………………………………………………………………………………… …………………………….. 11 4.3. Larghezza di banda è Frequenza Centrale ………………………………………………………………………………………………………………………… ……………… 13 4.4. Carrier Enable………………………………………………………………………………………………………………………………………………… ………………………………………… 14 4.5. Indirizzu DU MAC…………………………………………………………………………………………………………………………………… …………………………………………14 4.6. CUS-Plane VLAN ID……………………………………………………………………………………………………………………… ……………………………………….. 15 4.7. Accessu à u Registru ……………………………………………………………………………………………………………………………………… ………………………………………… 15 4.8. Considerazioni di Dual Carrier……………………………………………………………………………………………………………………… …………………………… 16 5. Monitor di Statu ……………………………………………………………………………………………… ……………………………………………………………………..18 5.1. Monitor di Statu PTP ……………………………………………………………………………………………………………………………………… …………………………………. 18 5.2. Monitor di putenza ……………………………………………………………………………………………………………………………………… ……………………………………….18 5.3. Contatori ……………………………………………………………………………………………………………………………………… ………………………………………………………. 19 6. Strumenti di Manutenzione ………………………………………………………………………………………………………………………… ……………………………..20 6.1. Apparecchiatura di reset manuale ………………………………………………………………………………………………………………………… ………………………. 20 6.2. Ripristino del timeout MPLAN…………………………………………………………………………………………………………………………… …………………………… 20
© CrossFire X2RU User Manual | 2 di 21
1. Setup Radio
1.1. Interfaccia Radio
Truvate a Tabella 3-1 per e definizione di l'interfaccia mostrata in a figura sottu:
6
POTENZA EXTRA
62.06dBm di putenza di uscita
7
1
2
3
4
5
8 9 10 11
12
© CrossFire X2RU User Manual | 3 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
Numeru Index
Nome di u portu
Tabella 1-1 Definizione di l'interfaccia Descrizione
1
CH1
Duplex DL/UL RF Port 1
2
CH2
Duplex DL/UL RF Port 2
3
CH3
Duplex DL/UL RF Port 3
4
CH4
Duplex DL/UL RF Port 4
5
ALLARME
Portu d'Alarma Esternu
6
POWER
Interfaccia Socket Power
7
RET
Riservatu
8
GND
Metà a terra
9
DEBUG
Interfaccia di mantenimentu
10
OPS
Port OP per l'Uint precedente
11
OPM
Port OP riservatu à Cascade
12
LED
Indicatore LED di OP & System
* Aduprate u portu 10G è u modulu SFP +
Osservazioni Cunnette à l'antenna
GUI: https://10.7.3.200 predeterminatu Cunnette à DU/PTP Switch
Vede u Statu di l'indicatore è l'indicazione in a tabella sottu:
Indicatore otticu Verde Rossu N/A
Tabella 1-2 OPS/OPM OPTICAL INDICATOR Description Normale U ligame otticu ùn hè micca sincronizatu. U modulu otticu ùn hè micca cunnessu
Status Indicator Flash Green Solid Green Flash Red Solid Red Flash Orange Solid Orange
Descrizzione
Table 1-3 SYSTEM RUN INDICATOR
L'elementu funziona senza alarme
U software hè cascatu, ma si riavvia automaticamente in 3 minuti
L'elementu funziona ma cun alarme
U software hè cascatu (cù alarme), ma riavviarà automaticamente in 3 minuti
U software hè in aghjurnamentu
L'elementu hè avviatu
© CrossFire X2RU User Manual | 4 di 21
1.2. Cunnessione tipica
U Picture sottu mostra a cunnessione tipica di X2RU in una applicazione ORAN.
DU
X2RU
POTENZA EXTRA
62.06dBm di putenza di uscita
Sistema di antenna MIMO 4 × 4
Antenna GPS
Gran Maestru
Cambia PTP
Nota: Aduprate u portu 10G è u modulu SFP + per DU è X2RU.
Type FTLX8573D3BTL
Raccomandazione SFP+:
Debug PC
Status Validatu
© CrossFire X2RU User Manual | 5 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
2. Radio Login
Attualmente X2RU usa u portu Ethernet di debug locale per a radio O&M. Hè utilizendu un indirizzu IP fissu di 10.7.3.200. Per accede à a radiu, cunfirmà chì l'indirizzu IP di u PC hè accessibile per a radiu. A foto sottu mostra un example.
2.1. Abilita a GUI cù a porta di daretu
Per l'ultima versione, a GUI serà disattivata per considerazioni di sicurezza, tutte e cunfigurazioni saranu spinte da M-Plane. In questu casu, hè assai inconveniente per a radiu IOT è debug. Una porta posteriore pò esse usata per attivà a GUI, seguite i passi sottu per questa funzione:
Passu #1 - Apertura a cunsola di cumandamentu di Windows è aduprà u cumandamentu: ssh dasUser@10.7.3.200
Passu #2 - Entre password: CF!DasUser@sw1
Step #3 - Aduprà u cumandamentu di colpu in a cunsola: toccu /tmp/boa.txt
Step #4 - Aspetta 3 minuti per ottene l'autorità GUI
© CrossFire X2RU User Manual | 6 di 21
2.2. Login à l'OMT
Per piacè entre https://10.7.3.200 in un navigatore Internet per visità u web GUI.
POTENZA EXTRA
62.06dBm di putenza di uscita
À a pagina di login, aduprate e credenziali mostrate quì sottu: User
Codice
amministratore amministratore
2.3. Console login
À l'attuale integrazione stage, qualchì volta avissi bisognu di accessu à a cunsola per debug o monitorà a radiu. Per piacè utilizate qualsiasi arnesi SSH per accede à a cunsola radio via dasUser@10.7.3.200.
Password: CF!DasUser@sw1 U login puderia esse denegatu per a prima volta, per piacè pruvate cù a credenza di novu.
© CrossFire X2RU User Manual | 7 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
3. Upgrade
3.1. Verificate a versione di u firmware
L'infurmazione di a versione di u firmware hè in a pagina Mantenimentu -> Ingegneria è Configurazione> Connettività LAN, pudete seguità l'indicatore rossu mostratu in i ritratti sottu. 1) Piglià u seguenti prugrammu firmware cum'è example, u numeru di versione hè mostratu in l'imagine seguente:
Software Version 2) Decompress u pacchettu di u prugramma firmware per vede i numeri di versione è CRC di altri prugrammi, cum'è ARM, PA è SETUP_NETCONF.
M-plane App CRC verifica ARM CRC verifica
Versione di distribuzione Netconf Versione FPGA
FileVersione di u sistema
3) U numeru di versione è CRC (~) in u prugramma di firmware sopra ponu currisponde à a visualizazione in OMT unu per unu, cum'è mostra in e seguenti figure:
© CrossFire X2RU User Manual | 8 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
Dopu cliccate nant'à u buttone "Query all" mustratu in a stampa cù marca blu. L'infurmazioni CRC per u firmware attualmente in usu apparirà in a casella marcata cù rossu. Nota à in a figura seguente mostra l'infurmazioni firmware di u dispusitivu attuale. Pudete paragunà l'infurmazioni di u firmware cù u pacchettu di u software per verificà se u firmware hè aghjurnatu o cunfirmà u risultatu di l'aghjurnamentu.
3.2. Aghjurnate cù una nova carica
Cliccate nant'à u buttone Upgrade mostratu in a pagina principale sottu.
Dopu à entre in a pagina di aghjurnamentu, cliccate nant'à u buttone "Carica" mostra sottu; a file serà dumandatu, selezziunate u pacchettu per aghjurnà a radiu. Dopu à u pacchettu hè statu sceltu è uploaded, Selezziunà u firmware à esse aghjurnata secondu à Step , è cliccate "upgrade forzatu" à aghjurnà u firmware.
Un avvisu apparirà cum'è mostratu quì sottu, cliccate nant'à u buttone OK.
Tandu sarà dumandata una password per "Force Upgrade", entre "iDas" è cunfirmà.
© CrossFire X2RU User Manual | 9 di 21
POTENZA EXTRA
62.06dBm Output Power Quandu vede u missaghju mostratu quì sottu, l'aghjurnamentu hè statu finitu è a radiu hè andatu per un reboot. Per piacè, aspittà finu à chì u boot di a radio sia in esecuzione cù u novu firmware.
3.3. Configurazione di carica (se necessariu)
Cliccate nant'à u buttone Configurazione -> Carica Configurazione mostra in a pagina principale sottu; Cliccate u buttone di carica per carica a cunfigurazione file;
S'ellu hè caricatu ssssssssssuccessfully, ci sarà una finestra prompt.
© CrossFire X2RU User Manual | 10 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
4. Configurazione Carrier
4.1. Fattore di cunversione di putenza
Attesa DL Digital IQ Input Power to RU in dBFS per Max Rated TX Output Power à u portu di l'antenna. RE Ave Power (dBFS) -13.7
4.2. Configurazione eAxC
A cunfigurazione eAxC hè predefinita cum'è mostra quì sottu:
Sta-LLRE-C00-P00-0 (RXA0P00C00)
Sta-LLRE-C00-P00-1 (PRACHA0P00C00)
Sta-LLRE-C00-P01-0 (RXA0P01C00)
Sta-LLRE-C00-P01-1 (PRACHA0P01C00)
Sta-LLRE-C00-P02-0 (RXA0P02C00)
Sta-LLRE-C00-P02-1 (PRACHA0P02C00)
Sta-LLRE-C00-P03-0 (RXA0P03C00)
Sta-LLRE-C00-P03-1 (PRACHA0P03C00)
Sta-LLRE-C01-P00-0 (RXA0P00C01)
Sta-LLRE-C01-P00-1 (PRACHA0P00C01)
Sta-LLRE-C01-P01-0 (RXA0P01C01)
Sta-LLRE-C01-P01-1 (PRACHA0P01C01)
Sta-LLRE-C01-P02-0 (RXA0P02C01)
Sta-LLRE-C01-P02-1 (PRACHA0P02C01)
Sta-LLRE-C01-P03-0 (RXA0P03C01)
Sta-LLRE-C01-P03-1 (PRACHA0P03C01)
LLRE-C00-P00-0(RXA0P00C00) EAXCID=0000 0000 0000 0000
LLRE-C00-P00-1(PRACHA0P00C00) EAXCID=0000 0000 0000 1000
LLRE-C00-P01-0(RXA0P01C00) EAXCID=0000 0000 0000 0001
LLRE-C00-P01-1(PRACHA0P01C00) EAXCID=0000 0000 0000 1001
LLRE-C00-P02-0(RXA0P02C00) EAXCID=0000 0000 0000 0010
LLRE-C00-P02-1(PRACHA0P02C00) EAXCID=0000 0000 0000 1010
LLRE-C00-P03-0(RXA0P03C00) EAXCID=0000 0000 0000 0011
LLRE-C00-P03-1(PRACHA0P03C00) EAXCID=0000 0000 0000 1011
LLRE-C01-P00-0(RXA0P00C01) EAXCID=0000 0000 0001 0000
LLRE-C01-P00-1(PRACHA0P00C01) EAXCID=0000 0000 0001 1000
LLRE-C01-P01-0(RXA0P01C01) EAXCID=0000 0000 0001 0001
LLRE-C01-P01-1(PRACHA0P01C01) EAXCID=0000 0000 0001 1001
LLRE-C01-P02-0(RXA0P02C01) EAXCID=0000 0000 0001 0010
LLRE-C01-P02-1(PRACHA0P02C01) EAXCID=0000 0000 0001 1010
LLRE-C01-P03-0(RXA0P03C01) EAXCID=0000 0000 0001 0011
LLRE-C01-P03-1(PRACHA0P03C01) EAXCID=0000 0000 0001 1011
LLRL0 (RXA0P00C00)
LLRL1 (PRACHA0P00C00)
LLRL2 (RXA0P01C00)
LLRL3 (PRACHA0P01C00)
LLRL4 (RXA0P02C00)
LLRL5 (PRACHA0P02C00)
LLRL6 (RXA0P03C00)
LLRL7 (PRACHA0P03C00)
LLRL8 (RXA0P00C01)
LLRL9 (PRACHA0P00C01)
LLRL10 (RXA0P01C01)
LLRL11 (PRACHA0P01C01)
LLRL12 (RXA0P02C01)
LLRL13 (PRACHA0P02C01)
LLRL14 (RXA0P03C01)
LLRL15 (PRACHA0P03C01)
RXArray0 (RXArray0)
Portu FH di l'interfaccia Itef (ETH1)
Sta-LLRE-C02-P00-0 (RXA0P00C02)
Sta-LLRE-C02-P00-1 (PRACHA0P00C02)
Sta-LLRE-C02-P01-0 (RXA0P01C02)
Sta-LLRE-C02-P01-1 (PRACHA0P01C02)
Sta-LLRE-C02-P02-0 (RXA0P02C02)
Sta-LLRE-C02-P02-1 (PRACHA0P02C02)
Sta-LLRE-C02-P03-0 (RXA0P03C02)
Sta-LLRE-C02-P03-1 (PRACHA0P03C02)
Sta-LLRE-C03-P00-0 (RXA0P00C03)
Sta-LLRE-C03-P00-1 (PRACHA0P00C03)
Sta-LLRE-C03-P01-0 (RXA0P01C03)
Sta-LLRE-C03-P01-1 (PRACHA0P01C03)
Sta-LLRE-C03-P02-0 (RXA0P02C03)
Sta-LLRE-C03-P02-1 (PRACHA0P02C03)
Sta-LLRE-C03-P03-0 (RXA0P03C03)
Sta-LLRE-C03-P03-1 (PRACHA0P03C03)
Elementu di trasfurmazioni (PE0)
LLRE-C02-P00-0(RXA0P00C02) EAXCID=0000 0000 0002 0000
LLRE-C02-P00-1(PRACHA0P00C02) EAXCID=0000 0000 0002 1000
LLRE-C02-P01-0(RXA0P01C02) EAXCID=0000 0000 0002 0001
LLRE-C02-P01-1(PRACHA0P01C02) EAXCID=0000 0000 0002 1001
LLRE-C02-P02-0(RXA0P02C02) EAXCID=0000 0000 0002 0010
LLRE-C02-P02-1(PRACHA0P02C02) EAXCID=0000 0000 0002 1010
LLRE-C02-P03-0(RXA0P03C02) EAXCID=0000 0000 0002 0011
LLRE-C02-P03-1(PRACHA0P03C02) EAXCID=0000 0000 0002 1011
LLRE-C03-P00-0(RXA0P00C03) EAXCID=0000 0000 0003 0000
LLRE-C03-P00-1(PRACHA0P00C03) EAXCID=0000 0000 0003 1000
LLRE-C03-P01-0(RXA0P01C03) EAXCID=0000 0000 0003 0001
LLRE-C03-P01-1(PRACHA0P01C03) EAXCID=0000 0000 0003 1001
LLRE-C03-P02-0(RXA0P02C03) EAXCID=0000 0000 0003 0010
LLRE-C03-P02-1(PRACHA0P02C03) EAXCID=0000 0000 0003 1010
LLRE-C03-P03-0(RXA0P03C03) EAXCID=0000 0000 0003 0011
LLRE-C03-P03-1(PRACHA0P03C03) EAXCID=0000 0000 0003 1011
LLRL0 (RXA0P00C02)
LLRL1 (PRACHA0P00C02)
LLRL2 (RXA0P01C02)
LLRL3 (PRACHA0P01C02)
LLRL4 (RXA0P02C02)
LLRL5 (PRACHA0P02C02)
LLRL6 (RXA0P03C02)
LLRL7 (PRACHA0P03C02)
LLRL8 (RXA0P00C03)
LLRL9 (PRACHA0P00C03)
LLRL10 (RXA0P01C03)
LLRL11 (PRACHA0P01C03)
LLRL12 (RXA0P02C03)
LLRL13 (PRACHA0P02C03)
LLRL14 (RXA0P03C03)
LLRL15 (PRACHA0P03C03)
RX-Arra y-Carrier0 (RXA0CC00)
RX-Arra y-Carrier1 (RXA0CC01)
RX-Arra y-Carrier2 (RXA0CC02)
RX-Arra y-Carrier1 (RXA0CC03)
© CrossFire X2RU User Manual | 11 di 21
TXArray0 (TXArray0)
Sta-LLTE-C00-P00-0 (TXA0P00C00)
Sta-LLTE-C00-P01-0 (TXA0P01C00)
Sta-LLTE-C00-P02-0 (TXA0P02C00)
Sta-LLTE-C00-P03-0 (TXA0P03C00)
Sta-LLTE-C01-P00-0 (TXA0P00C01)
Sta-LLTE-C01-P01-0 (TXA0P01C01)
Sta-LLTE-C01-P02-0 (TXA0P02C01)
Sta-LLTE-C01-P03-0 (TXA0P03C01)
Portu FH di l'interfaccia Itef (ETH1)
LLTE-C00-P00-0(TXA0P00C00) EAXCID=0000 0000 0000 0000
LLTE-C00-P01-0(TXA0P01C00) EAXCID=0000 0000 0000 0001
LLTE-C00-P02-0(TXA0P02C00) EAXCID=0000 0000 0000 0010
LLTE-C00-P03-0(TXA0P03C00) EAXCID=0000 0000 0000 0011
LLTE-C01-P00-0(TXA0P01C00) EAXCID=0000 0000 0001 0000
LLTE-C01-P01-0(TXA0P01C01) EAXCID=0000 0000 0001 0001
LLTE-C01-P02-0(TXA0P02C01) EAXCID=0000 0000 0001 0010
LLTE-C01-P03-0(TXA0P03C01) EAXCID=0000 0000 0001 0011
Elementu di trasfurmazioni (PE0)
POTENZA EXTRA
62.06dBm di putenza di uscita
LLTL0 (TXA0P00C00)
LLTL1 (TXA0P01C00)
LLTL2 (TXA0P02C00)
TX-Array-Carrier0 (TXA0CC00)
LLTL3 (TXA0P03C00)
LLTL4 (TXA0P00C01)
LLTL5 (TXA0P01C01)
LLTL6 (TXA0P02C01)
LLTL7 (TXA0P03C01)
TX-Array-Carrier1 (TXA0CC01)
Sta-LLTE-C02-P00-0 (TXA0P00C02)
Sta-LLTE-C02-P01-0 (TXA0P01C02)
LLTE-C02-P00-0(TXA0P00C02) EAXCID=0000 0000 0002 0000
LLTE-C02-P01-0(TXA0P01C02) EAXCID=0000 0000 0002 0001
LLTL0 (TXA0P00C02)
LLTL1 (TXA0P01C02)
Sta-LLTE-C02-P02-0 (TXA0P02C02)
Sta-LLTE-C02-P03-0 (TXA0P03C02)
LLTE-C02-P02-0(TXA0P02C02) EAXCID=0000 0000 0002 0010
LLTE-C02-P03-0(TXA0P03C02) EAXCID=0000 0000 0002 0011
LLTL2 (TXA0P02C02)
LLTL3 (TXA0P03C02)
Sta-LLTE-C03-P00-0 (TXA0P00C03)
Sta-LLTE-C03-P01-0 (TXA0P01C03)
LLTE-C03-P00-0(TXA0P01C00) EAXCID=0000 0000 0003 0000
LLTE-C03-P01-0(TXA0P01C03) EAXCID=0000 0000 0003 0001
LLTL4 (TXA0P00C03)
LLTL5 (TXA0P01C03)
Sta-LLTE-C03-P02-0 (TXA0P02C03)
LLTE-C03-P02-0(TXA0P02C03) EAXCID=0000 0000 0003 0010
LLTL6 (TXA0P02C03)
Sta-LLTE-C03-P03-0 (TXA0P03C03)
LLTE-C03-P03-0(TXA0P03C03) EAXCID=0000 0000 0003 0011
LLTL7 (TXA0P03C03)
Mentre ci sò ancu alcuni parametri attualmente deve esse cunfigurati però web OMT.
TX-Array-Carrier2 (TXA0CC02)
TX-Array-Carrier3 (TXA0CC03)
© CrossFire X2RU User Manual | 12 di 21
4.3. Larghezza di banda è Frequenza Centrale
A cunfigurazione di u trasportatore pò esse truvata in a pagina "Settings -> Carrier Info".
POTENZA EXTRA
62.06dBm di putenza di uscita
Pudete truvà u stessu mudellu di paràmetri di trasportatore per C0, C1, C2 è C3, quì pigliamu C0 cum'è ex.ample. Frequency
Per piacè utilizate l'ARFCN di u trasportatore invece di a freccia centrale per a GUI. Dopu chì l'ARFCN hè stabilitu, l'infurmazioni di freccia pò esse cunfirmata in a sezione di l'infurmazione di u trasportatore cum'è mostra in i scatuli numerati è a stampa sopra. A larghezza di banda per u trasportatore currispundente, a larghezza di banda hè selezziunata trà 5M / 10M / 15M / 20M. DL Gain U dispusitivu pò sintonizà a putenza di output downlink di u dispusitivu cunfigurà u paràmetru DL Gain. Se u traspurtadore ùn hè micca utilizatu, fate questu valore à -50. Algoritmu di calculu:
Antenna Output Power = DL_Max_Power (C0) + DL_Max_Power (C1) + DL_Max_Power (C2) + DL_Max_Power (C3) ;
DL_Max_Power(Cn) = 46 dBm + (DL Gain(Cn) 58 dB ) , (n = 0~1) ; Rated Antenna Output Power = 46 dBm; Rated DL Gain = 58 dB;
© CrossFire X2RU User Manual | 13 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
CC Num 1 1 2 2 3 3 4 4
CC 0 DL Gain/dB 58 55 55 52 53 50 52 49
CC 1 DL Gain/dB -50 -50 55 52 53 50 52 49
CC 2 DL Gain/dB -50 -50 -50 -50 53 50 52 49
CC 3 DL Gain/dB -50 -50 -50 -50 -50 -50 52 49
Potenza di Output Antenna /dBm 46 43 46 43 46 43 46 43
Correzione di guadagnu UL Per piacè mette à 0 per questa versione. Ùn hè micca usatu attualmente. Per piacè cunfirmà u statutu di checkbox per i paràmetri prima di cliccà "Set", altrimenti ùn serà micca applicatu. Dopu chì l'infurmazione di u trasportatore hè stabilitu, u buttone d'aghjurnamentu deve esse clicatu per applicà a mudificazione, hè situatu à u fondu di a GUI. U buttone d'aghjurnà diventa verde dopu à cliccà, se u buttone diventa rossu, indica chì l'errore hè rilevatu in i paràmetri di u trasportatore.
4.4. Carrier Enable
I trasportatori ponu esse attivati è chjusi da inserisce ACTIVE o INACTIVE in u campu mostratu sopra. Se u traspurtadore ùn hè micca utilizatu, per piacè mette in INACTIVE. L'aghjurnamentu deve esse clicatu per applicà dopu chì sti parametri sò cambiati.
4.5. DU MAC Indirizzu
L'indirizzu MAC DU pò esse stabilitu in a pagina GUI Setting ->LAN Connectivity.
© CrossFire X2RU User Manual | 14 di 21
4.6. CUS-Plane VLAN ID
CUS-Plane VLAN ID pò esse stabilitu in a pagina GUI Setting ->LAN Connectivity.
POTENZA EXTRA
62.06dBm di putenza di uscita
4.7. Registrate Accessu
Passu #1 Entra in u modu di fabbrica (per piacè riferite à a sezione 4.6). Passu #2 Entra in a pagina "Modulu Digital -> Interfaccia Indirizzu". Passu #3 Selezziunà "FPGA" per u campu "Chip Select". Step #4 Entre in Register Address, length (sempre stabilitu à 4). Passu #5 Cliccate "Query" per u valore attuale mostratu in u campu di cuntenutu è "Set" per applicà u novu valore dopu a mudificazione.
© CrossFire X2RU User Manual | 15 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
4.8. Considerazioni di Dual Carrier
Certi considerazioni extra sò necessarii quandu 2 trasportatori sò usati: 1) Frequency Quandu 2 trasportatori sò usati, i paràmetri di freccia in a GUI sò indipendenti per i dui trasportatori. Ma una cura particulare deve esse presa per evità di sovrapposizioni di u trasportatore.
Frequency (ARFCN1) Frequency (ARFCN0) >= (Bw0 + Bw1) /2
cc0
cc1
bw0
bw1
ARFCN 0
ARFCN 1
Per i paràmetri di frequenza, truvate i paràmetri mostrati in l'istantanea sottu:
© CrossFire X2RU User Manual | 16 di 21
POTENZA EXTRA
62.06dBm Output Power 2) Configurazione di guadagnà U dispusitivu pò definisce a putenza di output downlink di u dispusitivu cunfigurà u paràmetru DL Gain in l'OMT. Pigliate C0
traspurtadore cum'è example, a relazione currispundenti trà a putenza di uscita downlink è DL Gain hè mostrata cum'è seguente: 46 dBm + ( DL Gain (C0) 58 dB ) = DL Max Power (C0)
Nota: 58dB hè u guadagnu nominale di l'equipaggiu, è 46dBm hè a putenza nominale di output downstream di l'equipaggiu. Quandu 2 trasportatori sò usati, per i trasportatori DL 2 sparteranu a putenza di output nominale di 46dBm.
A limitazione hè: Max_Power (C0) + Max_Power (C1) <= 46 dbm
Pudete cambià i paràmetri di guadagnu DL per u trasportatore 0 è 1 per suddisfà l'equazione mostrata sopra. Per dumandà u DL Max Power, truvate a sezione sottu in a Pagina di Cunfigurazione di Carrier.
Cù cunfigurazioni currette, l'infurmazione di u modulu mostrarà validu in a dumanda dopu à cliccà u buttone "Aggiornamentu".
© CrossFire X2RU User Manual | 17 di 21
5. Status Monitor
5.1. Monitor di Status PTP
1) Statu PTP
POTENZA EXTRA
62.06dBm di putenza di uscita
U statutu PTP pò esse truvatu in a pagina Settings -> Radio Signal Information, a luce verde indica un bonu statu PTP.
5.2. Monitor di putenza
1) Antenna Power Antenna input / output power pò esse truvata in a pagina "Settings -> Radio Signal Information".
2) Antenna Baseband Power Antenna baseband power Transmitted/Received at antenna pò esse verificatu da GUI in pagina Settings -> Radio Signal Information. A putenza di a banda di base hè indicata in dBm.
© CrossFire X2RU User Manual | 18 di 21
3) Carrier Power Carrier Power pò esse truvatu in a pagina "Settings -> Stream Info".
POTENZA EXTRA
62.06dBm di putenza di uscita
L'immagine sopra mostra a putenza di banda di base UL/DL di carrier0 in dBm.
5.3. Cuntaturi
1) Contatori eCPRI U numeru di pacchetti U-plane è pacchetti C-plane pò esse monitoratu in a pagina GUI Maintenance -> Engineering.
© CrossFire X2RU User Manual | 19 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
6. Strumenti di mantenimentu
6.1. Reset manuale di l'equipaggiu
U dispusitivu supporta u reset manuale nantu à l'OMT, pudete truvà u buttone di reset di Hardware in a pagina GUI Maintenance -> Engineering.
6.2. MPLONE Timeout Reset
1) Se u buttone di reset MPLONE Timeout hè attivatu In 24 ore dopu à l'iniziu di u dispositivu, se a piattaforma CMS ùn hè micca cunnessa cun successu, u dispusitivu serà attivamente resettatu à un intervallu d'ora. Se u CMS hè cunnessu cù successu una volta è ùn hè micca realizatu alcuna operazione di reset, u CMS ferma di detectà a cunnessione è ùn attiva micca u mecanismu di reset automaticu di 24 ore.
2) Se u buttone di reset MPLONE Timeout hè disattivatu U dispusitivu ùn detecta micca a cunnessione à a piattaforma CMS è ùn resette micca u dispusitivu. Per quessa, se u dispusitivu hè esse debugged, vi sò cunsigliatu di disattivà u switch.
© CrossFire X2RU User Manual | 20 di 21
POTENZA EXTRA
62.06dBm di putenza di uscita
Avvisu FCC: Stu dispusitivu deve esse installatu prufessiunale.
Per piacè fate attenzione chì cambiamenti o mudificazione chì ùn sò micca appruvati espressamente da a parte rispunsevuli di a conformità puderanu annullà l'autorità di l'utilizatore per operà l'equipaggiu. Stu dispusitivu hè conforme à a Parte 15 di e regule FCC. U funziunamentu hè sottumessu à e duie cundizioni seguenti: (1) Stu dispusitivu ùn pò micca causà interferenze dannusu, è (2) Stu dispusitivu deve accettà ogni interferenza ricevuta, cumpresa l'interferenza chì pò causà operazione indesiderata. Stu equipamentu hè conforme à i limiti di esposizione à a radiazione FCC stabiliti per un ambiente senza cuntrollu. Stu equipamentu deve esse stallatu è operatu cù una distanza minima di 358.5 cm trà u radiatore è u vostru corpu.
NOTA: Solu a persona autorizata pò entre in l'area induve l'antenna hè stallata. È a persona hè sanu sanu di u putenziale di l'esposizione è pò esercitarà u cuntrollu di a so esposizione abbandunendu l'area o per qualchì altru mezzu adattatu. A cuscenza di u putenziale di l'esposizione RF in un locu di travagliu o un ambiente simile pò esse furnita per via di furmazione specifica cum'è parte di un prugramma di sicurezza RF.
© CrossFire X2RU User Manual | 21 di 21
Documenti / Risorse
![]() |
Parallel Wireless DRRU-R428 OpenRAN Network Software [pdfManuale d'usu R42841, 2AI7FR42841, DRRU-R428 OpenRAN Network Software, DRRU-R428, OpenRAN Network Software, Network Software, Software |