Paralelni bežični DRRU-R428 OpenRAN mrežni softver korisnički priručnik

DRRU-R428 OpenRAN mrežni softver

DRRU-R428 Korisničko uputstvo

Sadržaj

DODATNA SNAGA
Izlazna snaga 62.06dBm

1. Podešavanje radija …………………………………………………………………………………………………………………………………………………………………………………………… 3 1.1. Radio interfejs …………………………………………………………………………………………………………………………………………………………………………………………………..3 1.2. Tipična veza………………………………………………………………………………………………………………………………………………………………………………….5 2. Radio prijava ……………………………………………………………………………………………………………………………………………………………………………………………. 6 2.1. Omogući GUI sa stražnjim vratima………………………………………………………………………………………………………………………………………………………………………6 2.2. OMT prijava ………………………………………………………………………………………………………………………………………………………………………………………………………….. 7 2.3. Prijava na konzolu ………………………………………………………………………………………………………………………………………………………………………………………… 7 3. Nadogradnja ………………………………………………………………………………………………………………………………………………………………………………………………. 8 3.1. Provjera verzije firmvera……………………………………………………………………………………………………………………………………………………………………………..8 3.2. Nadogradnja s novim opterećenjem………………………………………………………………………………………………………………………………………………………………………9 3.3. Učitavanje konfiguracije (ako je potrebno) ……………………………………………………………………………………………………………………………………………………. 10 4. Konfiguracija nosioca …………………………………………………………………………………………………………………………………………………………………… 11 4.1. Faktor konverzije snage ………………………………………………………………………………………………………………………………………………………………….. 11 4.2. eAxC konfiguracija ……………………………………………………………………………………………………………………………………………………………………………….. 11 4.3. Širina pojasa i središnja frekvencija ……………………………………………………………………………………………………………………………………………………… 13 4.4. Omogućavanje operatera 14 4.5. DU MAC adresa………………………………………………………………………………………………………………………………………………………………………………………………14 4.6. CUS-Plane VLAN ID…………………………………………………………………………………………………………………………………………………………………………………………….. 15 4.7. Pristup registru ………………………………………………………………………………………………………………………………………………………………………………………………… 15 4.8. Razmatranja dvostrukog nosioca …………………………………………………………………………………………………………………………………………………… 16 5. Monitor statusa ………………………………………………………………………………………………………………………………………………………………………………………..18 5.1. PTP Status Monitor ……………………………………………………………………………………………………………………………………………………………………………………………. 18 5.2. Monitor napajanja………………………………………………………………………………………………………………………………………………………………………………………………….18 5.3. Brojači ……………………………………………………………………………………………………………………………………………………………………………………………………………. 19 6. Alati za održavanje …………………………………………………………………………………………………………………………………………………………………..20 6.1. Oprema za ručno resetovanje……………………………………………………………………………………………………………………………………………………………………. 20 6.2. MPLANE Timeout Reset …………………………………………………………………………………………………………………………………………………………………………………………… 20

© CrossFire X2RU Korisnički priručnik | 2 od 21

1. Radio Setup
1.1. Radio Interface
Nađite tabelu 3-1 za definicije interfejsa prikazane na slici ispod:
6

DODATNA SNAGA
Izlazna snaga 62.06dBm

7

1

2

3

4

5
8 9 10 11

12

© CrossFire X2RU Korisnički priručnik | 3 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm

Broj indeksa

Port Name

Tabela 1-1 Opis definicije interfejsa

1

CH1

Dupleks DL/UL RF port 1

2

CH2

Dupleks DL/UL RF port 2

3

CH3

Dupleks DL/UL RF port 3

4

CH4

Dupleks DL/UL RF port 4

5

ALARM

Port za eksterni alarm

6

POWER

Interfejs utičnice za napajanje

7

RET

Rezervirano

8

GND

Uzemljenje

9

DEBUG

Interfejs za održavanje

10

OPS

OP port za prethodnu jedinicu

11

OPM

OP port rezerviran za Cascade

12

LED

LED indikator OP & sistema

* Molimo koristite 10G port i SFP+ modul

Napomene Povežite na antenu
GUI: https://10.7.3.200 default Povežite se na DU/PTP prekidač

Pogledajte Status indikatora i indikaciju u tabeli ispod:

Optički indikator Zelena Crvena N/A

Tabela 1-2 OPS/OPM OPTIČKI INDIKATOR Opis Normalno Optička veza nije sinhronizirana. Optički modul nije priključen

Indikator statusa treperi Zeleno Stalno Zeleno Treperi crveno Stalno Crveno Treperi Narandžasto Stalno Narandžasto

Opis

Tabela 1-3 INDIKATOR RADA SISTEMA

Element radi bez alarma

Softver je pao, ali će se automatski ponovo pokrenuti za 3 minute

Element radi ali sa alarmom

Softver je pao (sa alarmom), ali će se automatski ponovo pokrenuti za 3 minute

Softver se nadograđuje

Element se pokreće

© CrossFire X2RU Korisnički priručnik | 4 od 21

1.2. Tipična veza
Slika ispod prikazuje tipično povezivanje X2RU u ORAN aplikaciji.

DU

X2RU

DODATNA SNAGA
Izlazna snaga 62.06dBm
4×4 MIMO antenski sistem

GPS antena

Veliki majstor

PTP prekidač

Napomena: Molimo koristite 10G port i SFP+ modul za DU i X2RU.

Tip FTLX8573D3BTL

SFP+ preporuka:

Debug PC
Status Validated

© CrossFire X2RU Korisnički priručnik | 5 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm
2. Radio Prijava
Trenutno X2RU koristi lokalni Ethernet port za otklanjanje grešaka za radio O&M. Koristi fiksnu IP adresu 10.7.3.200. Da biste se prijavili na radio, potvrdite da je IP adresa računara dostupna za radio. Slika ispod prikazuje bivšegample.
2.1. Omogućite GUI sa stražnjim vratima
Za najnoviju verziju, GUI će biti onemogućen iz sigurnosnih razloga, sve konfiguracije će biti potisnute iz M-Planea. U ovom slučaju, vrlo je nezgodno za radio IOT i otklanjanje grešaka. Stražnja vrata se mogu koristiti za omogućavanje GUI, molimo slijedite dolje navedene korake za ovu funkciju:
Korak #1 – Otvorite Windows komandnu konzolu i koristite naredbu: ssh dasUser@10.7.3.200
Korak #2 – Unesite lozinku: CF!DasUser@sw1
Korak #3 – Koristite komandu blow u konzoli: dodirnite /tmp/boa.txt
Korak #4 – Pričekajte 3 minute da dobijete GUI ovlaštenje
© CrossFire X2RU Korisnički priručnik | 6 od 21

2.2. OMT Login
Unesite https://10.7.3.200 u internet pretraživač da posetite web GUI.

DODATNA SNAGA
Izlazna snaga 62.06dBm

Na stranici za prijavu koristite akreditive prikazane ispod: Korisnik
Lozinka

admin admin

2.3. Prijava na konzolu
U trenutnoj integraciji stage, ponekad bi bio potreban pristup konzoli za otklanjanje grešaka ili nadgledanje radija. Koristite bilo koji SSH alat za prijavu na radio konzolu putem dasUser@10.7.3.200.
Lozinka: CF!DasUser@sw1 Prijava može biti odbijena po prvi put, pokušajte ponovo sa akreditivom.

© CrossFire X2RU Korisnički priručnik | 7 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm
3. Nadogradnja
3.1. Provjera verzije firmvera
Informacije o verziji firmvera nalaze se na stranici Održavanje -> Inženjering i podešavanja > LAN povezivanje, možete pratiti crveni indikator prikazan na slikama ispod. 1) Uzmite sljedeći firmver program kao nprample, broj verzije je prikazan na sljedećoj slici:
Verzija softvera 2) Dekomprimirajte paket firmverskog programa da biste vidjeli brojeve verzija i CRC drugih programa, kao što su ARM, PA i SETUP_NETCONF.
M-plane App CRC provjera ARM CRC provjera
Verzija Netconf implementacije Verzija FPGA
FileVerzija sistema
3) Broj verzije i CRC (~) u gore navedenom firmver programu mogu odgovarati prikazu u OMT-u jedan po jedan, kao što je prikazano na sljedećim slikama:
© CrossFire X2RU Korisnički priručnik | 8 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm
Zatim kliknite na dugme „Upitaj sve“ prikazano na slici sa plavom oznakom. CRC informacije za firmver koji se trenutno koristi pojavit će se u polju označenom crvenom bojom. Napomena da se na sljedećoj slici prikazuju informacije o firmveru trenutnog uređaja. Možete uporediti informacije o firmveru sa softverskim paketom kako biste provjerili je li firmver ažuriran ili potvrdili rezultat nadogradnje.
3.2. Nadogradite s novim opterećenjem
Kliknite na dugme Upgrade prikazano na glavnoj stranici ispod.

Nakon što uđete na stranicu za nadogradnju, kliknite na dugme “Učitaj” prikazano ispod; a file će biti zatraženo, odaberite paket za nadogradnju radija. Nakon što je paket odabran i učitan, odaberite firmver za nadogradnju u skladu sa korakom i kliknite na „prisilna nadogradnja“ da nadogradite firmver.
Pojavit će se upozorenje kao što je prikazano ispod, kliknite na dugme OK.
Zatim će se tražiti lozinka za “Force Upgrade”, unesite “iDas” i potvrdite.
© CrossFire X2RU Korisnički priručnik | 9 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm Kada vidite dole prikazanu poruku, nadogradnja je završena i radio će se ponovo pokrenuti. Pričekajte dok se radio ne pokrene s novim firmverom.
3.3. Učitaj konfiguraciju (ako je potrebno)
Kliknite na dugme Konfiguracija –> Učitaj konfiguraciju prikazanu na glavnoj stranici ispod; Kliknite na dugme za otpremanje da biste učitali konfiguraciju file;
Ako se učitavaju SSSSSSSSSSSSSSSSISS, bit će prozorski prozor.
© CrossFire X2RU Korisnički priručnik | 10 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm

4. Konfiguracija operatera

4.1. Faktor konverzije snage

Očekivana DL digitalna IQ ulazna snaga do RU u dBFS za maksimalnu nominalnu izlaznu snagu TX na priključku za antenu. RE ave Power (dBFS)-13.7

4.2. eAxC konfiguracija

eAxC konfiguracija je unaprijed definirana kao što je prikazano ispod:
Sta-LLRE-C00-P00-0 (RXA0P00C00)
Sta-LLRE-C00-P00-1 (PRACHA0P00C00)
Sta-LLRE-C00-P01-0 (RXA0P01C00)
Sta-LLRE-C00-P01-1 (PRACHA0P01C00)
Sta-LLRE-C00-P02-0 (RXA0P02C00)
Sta-LLRE-C00-P02-1 (PRACHA0P02C00)
Sta-LLRE-C00-P03-0 (RXA0P03C00)
Sta-LLRE-C00-P03-1 (PRACHA0P03C00)
Sta-LLRE-C01-P00-0 (RXA0P00C01)
Sta-LLRE-C01-P00-1 (PRACHA0P00C01)
Sta-LLRE-C01-P01-0 (RXA0P01C01)
Sta-LLRE-C01-P01-1 (PRACHA0P01C01)
Sta-LLRE-C01-P02-0 (RXA0P02C01)
Sta-LLRE-C01-P02-1 (PRACHA0P02C01)
Sta-LLRE-C01-P03-0 (RXA0P03C01)
Sta-LLRE-C01-P03-1 (PRACHA0P03C01)

LLRE-C00-P00-0(RXA0P00C00) EAXCID=0000 0000 0000 0000
LLRE-C00-P00-1(PRACHA0P00C00) EAXCID=0000 0000 0000 1000
LLRE-C00-P01-0(RXA0P01C00) EAXCID=0000 0000 0000 0001
LLRE-C00-P01-1(PRACHA0P01C00) EAXCID=0000 0000 0000 1001
LLRE-C00-P02-0(RXA0P02C00) EAXCID=0000 0000 0000 0010
LLRE-C00-P02-1(PRACHA0P02C00) EAXCID=0000 0000 0000 1010
LLRE-C00-P03-0(RXA0P03C00) EAXCID=0000 0000 0000 0011
LLRE-C00-P03-1(PRACHA0P03C00) EAXCID=0000 0000 0000 1011
LLRE-C01-P00-0(RXA0P00C01) EAXCID=0000 0000 0001 0000
LLRE-C01-P00-1(PRACHA0P00C01) EAXCID=0000 0000 0001 1000
LLRE-C01-P01-0(RXA0P01C01) EAXCID=0000 0000 0001 0001
LLRE-C01-P01-1(PRACHA0P01C01) EAXCID=0000 0000 0001 1001
LLRE-C01-P02-0(RXA0P02C01) EAXCID=0000 0000 0001 0010
LLRE-C01-P02-1(PRACHA0P02C01) EAXCID=0000 0000 0001 1010
LLRE-C01-P03-0(RXA0P03C01) EAXCID=0000 0000 0001 0011
LLRE-C01-P03-1(PRACHA0P03C01) EAXCID=0000 0000 0001 1011

LLRL0 (RXA0P00C00)
LLRL1 (PRACHA0P00C00)
LLRL2 (RXA0P01C00)
LLRL3 (PRACHA0P01C00)
LLRL4 (RXA0P02C00)
LLRL5 (PRACHA0P02C00)
LLRL6 (RXA0P03C00)
LLRL7 (PRACHA0P03C00)
LLRL8 (RXA0P00C01)
LLRL9 (PRACHA0P00C01)
LLRL10 (RXA0P01C01)
LLRL11 (PRACHA0P01C01)
LLRL12 (RXA0P02C01)
LLRL13 (PRACHA0P02C01)
LLRL14 (RXA0P03C01)
LLRL15 (PRACHA0P03C01)

RXArray0 (RXArray0)

Itef-interfejs FH port (ETH1)
Sta-LLRE-C02-P00-0 (RXA0P00C02)
Sta-LLRE-C02-P00-1 (PRACHA0P00C02)
Sta-LLRE-C02-P01-0 (RXA0P01C02)
Sta-LLRE-C02-P01-1 (PRACHA0P01C02)
Sta-LLRE-C02-P02-0 (RXA0P02C02)
Sta-LLRE-C02-P02-1 (PRACHA0P02C02)
Sta-LLRE-C02-P03-0 (RXA0P03C02)
Sta-LLRE-C02-P03-1 (PRACHA0P03C02)
Sta-LLRE-C03-P00-0 (RXA0P00C03)
Sta-LLRE-C03-P00-1 (PRACHA0P00C03)
Sta-LLRE-C03-P01-0 (RXA0P01C03)
Sta-LLRE-C03-P01-1 (PRACHA0P01C03)
Sta-LLRE-C03-P02-0 (RXA0P02C03)
Sta-LLRE-C03-P02-1 (PRACHA0P02C03)
Sta-LLRE-C03-P03-0 (RXA0P03C03)
Sta-LLRE-C03-P03-1 (PRACHA0P03C03)

Procesni element (PE0)
LLRE-C02-P00-0(RXA0P00C02) EAXCID=0000 0000 0002 0000
LLRE-C02-P00-1(PRACHA0P00C02) EAXCID=0000 0000 0002 1000
LLRE-C02-P01-0(RXA0P01C02) EAXCID=0000 0000 0002 0001
LLRE-C02-P01-1(PRACHA0P01C02) EAXCID=0000 0000 0002 1001
LLRE-C02-P02-0(RXA0P02C02) EAXCID=0000 0000 0002 0010
LLRE-C02-P02-1(PRACHA0P02C02) EAXCID=0000 0000 0002 1010
LLRE-C02-P03-0(RXA0P03C02) EAXCID=0000 0000 0002 0011
LLRE-C02-P03-1(PRACHA0P03C02) EAXCID=0000 0000 0002 1011
LLRE-C03-P00-0(RXA0P00C03) EAXCID=0000 0000 0003 0000
LLRE-C03-P00-1(PRACHA0P00C03) EAXCID=0000 0000 0003 1000
LLRE-C03-P01-0(RXA0P01C03) EAXCID=0000 0000 0003 0001
LLRE-C03-P01-1(PRACHA0P01C03) EAXCID=0000 0000 0003 1001
LLRE-C03-P02-0(RXA0P02C03) EAXCID=0000 0000 0003 0010
LLRE-C03-P02-1(PRACHA0P02C03) EAXCID=0000 0000 0003 1010
LLRE-C03-P03-0(RXA0P03C03) EAXCID=0000 0000 0003 0011
LLRE-C03-P03-1(PRACHA0P03C03) EAXCID=0000 0000 0003 1011

LLRL0 (RXA0P00C02)
LLRL1 (PRACHA0P00C02)
LLRL2 (RXA0P01C02)
LLRL3 (PRACHA0P01C02)
LLRL4 (RXA0P02C02)
LLRL5 (PRACHA0P02C02)
LLRL6 (RXA0P03C02)
LLRL7 (PRACHA0P03C02)
LLRL8 (RXA0P00C03)
LLRL9 (PRACHA0P00C03)
LLRL10 (RXA0P01C03)
LLRL11 (PRACHA0P01C03)
LLRL12 (RXA0P02C03)
LLRL13 (PRACHA0P02C03)
LLRL14 (RXA0P03C03)
LLRL15 (PRACHA0P03C03)

RX-Arra y-Carrier0 (RXA0CC00)
RX-Arra y-Carrier1 (RXA0CC01)
RX-Arra y-Carrier2 (RXA0CC02)
RX-Arra y-Carrier1 (RXA0CC03)

© CrossFire X2RU Korisnički priručnik | 11 od 21

TXArray0 (TXArray0)

Sta-LLTE-C00-P00-0 (TXA0P00C00)
Sta-LLTE-C00-P01-0 (TXA0P01C00)
Sta-LLTE-C00-P02-0 (TXA0P02C00)
Sta-LLTE-C00-P03-0 (TXA0P03C00)
Sta-LLTE-C01-P00-0 (TXA0P00C01)
Sta-LLTE-C01-P01-0 (TXA0P01C01)
Sta-LLTE-C01-P02-0 (TXA0P02C01)
Sta-LLTE-C01-P03-0 (TXA0P03C01)
Itef-interfejs FH port (ETH1)

LLTE-C00-P00-0(TXA0P00C00) EAXCID=0000 0000 0000 0000
LLTE-C00-P01-0(TXA0P01C00) EAXCID=0000 0000 0000 0001
LLTE-C00-P02-0(TXA0P02C00) EAXCID=0000 0000 0000 0010
LLTE-C00-P03-0(TXA0P03C00) EAXCID=0000 0000 0000 0011
LLTE-C01-P00-0(TXA0P01C00) EAXCID=0000 0000 0001 0000
LLTE-C01-P01-0(TXA0P01C01) EAXCID=0000 0000 0001 0001
LLTE-C01-P02-0(TXA0P02C01) EAXCID=0000 0000 0001 0010
LLTE-C01-P03-0(TXA0P03C01) EAXCID=0000 0000 0001 0011
Procesni element (PE0)

DODATNA SNAGA
Izlazna snaga 62.06dBm
LLTL0 (TXA0P00C00)

LLTL1 (TXA0P01C00)
LLTL2 (TXA0P02C00)

TX-array-carrier0 (TXA0CC00)

LLTL3 (TXA0P03C00)

LLTL4 (TXA0P00C01)
LLTL5 (TXA0P01C01)
LLTL6 (TXA0P02C01)
LLTL7 (TXA0P03C01)

TX-array-carrier1 (TXA0CC01)

Sta-LLTE-C02-P00-0 (TXA0P00C02)
Sta-LLTE-C02-P01-0 (TXA0P01C02)

LLTE-C02-P00-0(TXA0P00C02) EAXCID=0000 0000 0002 0000
LLTE-C02-P01-0(TXA0P01C02) EAXCID=0000 0000 0002 0001

LLTL0 (TXA0P00C02)
LLTL1 (TXA0P01C02)

Sta-LLTE-C02-P02-0 (TXA0P02C02)
Sta-LLTE-C02-P03-0 (TXA0P03C02)

LLTE-C02-P02-0(TXA0P02C02) EAXCID=0000 0000 0002 0010
LLTE-C02-P03-0(TXA0P03C02) EAXCID=0000 0000 0002 0011

LLTL2 (TXA0P02C02)
LLTL3 (TXA0P03C02)

Sta-LLTE-C03-P00-0 (TXA0P00C03)
Sta-LLTE-C03-P01-0 (TXA0P01C03)

LLTE-C03-P00-0(TXA0P01C00) EAXCID=0000 0000 0003 0000
LLTE-C03-P01-0(TXA0P01C03) EAXCID=0000 0000 0003 0001

LLTL4 (TXA0P00C03)
LLTL5 (TXA0P01C03)

Sta-LLTE-C03-P02-0 (TXA0P02C03)

LLTE-C03-P02-0(TXA0P02C03) EAXCID=0000 0000 0003 0010

LLTL6 (TXA0P02C03)

Sta-LLTE-C03-P03-0 (TXA0P03C03)

LLTE-C03-P03-0(TXA0P03C03) EAXCID=0000 0000 0003 0011

LLTL7 (TXA0P03C03)

Iako još uvijek postoje neki parametri, trenutno je potrebno konfigurirati web OMT.

TX-array-carrier2 (TXA0CC02)
TX-array-carrier3 (TXA0CC03)

© CrossFire X2RU Korisnički priručnik | 12 od 21

4.3. Širina pojasa i središnja frekvencija
Konfiguraciju operatera možete pronaći na stranici “Postavke -> Informacije o operateru”.

DODATNA SNAGA
Izlazna snaga 62.06dBm

Možda ćete pronaći isti obrazac postavki operatera za C0, C1, C2 i C3, ovdje uzimamo C0 kao npr.ample. Frekvencija
Molimo koristite ARFCN nosioca umjesto središnje frekvencije za GUI. Nakon što je ARFCN podešen, informacije o frekvenciji mogu se potvrditi u odjeljku Informacije o nosiocu kao što je prikazano u poljima označenim brojevima i gornjoj slici. Bandwidth Bandwidth za odgovarajući nosilac, Bandwidth se može izabrati između 5M/10M/15M/20M. DL Gain Uređaj može podesiti izlaznu snagu uređaja za downlink konfigurisanjem parametra DL Gain. Ako se nosač ne koristi, postavite ovu vrijednost na -50. Algoritam proračuna:
Izlazna snaga antene = DL_Max_Power(C0) + DL_Max_Power(C1) + DL_Max_Power(C2) + DL_Max_Power(C3) ;
DL_Max_Power(Cn) = 46 dBm + (DL Gain(Cn) 58 dB) , (n = 0~1) ; Nazivna izlazna snaga antene = 46 dBm; Nazivno DL pojačanje = 58 dB;
© CrossFire X2RU Korisnički priručnik | 13 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm

CC Num 1 1 2 2 3 3 4 4

CC 0 DL pojačanje/dB 58 55 55 52 53 50 52 49

CC 1 DL pojačanje/dB -50 -50 55 52 53 50 52 49

CC 2 DL Pojačanje/dB -50 -50 -50 -50 53 50 52 49

CC 3 DL Pojačanje/dB -50 -50 -50 -50 -50 -50 52 49

Izlazna snaga antene /dBm 46 43 46 43 46 43 46 43

UL korekcija pojačanja Postavite je na 0 za ovu verziju. Trenutno se ne koristi. Molimo potvrdite status polja za potvrdu za parametre prije nego što se klikne na `Postavi', inače se neće primijeniti. Nakon što su informacije o operateru postavljene, potrebno je kliknuti na dugme za ažuriranje da biste primenili modifikaciju, nalazi se na dnu GUI. Dugme za ažuriranje će postati zeleno nakon klika, ako dugme postane crveno, znači da je otkrivena greška u postavkama operatera.

4.4. Carrier Enable

Nosioci se mogu omogućiti i zaključati unosom AKTIVNO ili NEAKTIVNO u polje prikazano iznad. Ako se nosač ne koristi, postavite ga na NEAKTIVNO. Potrebno je kliknuti na ažuriranje da bi se primijenilo nakon promjene ovih parametara.
4.5. DU MAC adresa
DU MAC adresa se može postaviti na stranici GUI Postavka ->LAN povezivanje.

© CrossFire X2RU Korisnički priručnik | 14 od 21

4.6. CUS-Plane VLAN ID
CUS-Plane VLAN ID se može postaviti na stranici GUI Postavka ->LAN povezivanje.

DODATNA SNAGA
Izlazna snaga 62.06dBm

4.7. Registrirajte pristup

Korak #1 Uđite u fabrički način rada (pogledajte odjeljak 4.6). Korak #2 Unesite stranicu “Digitalni modul -> Address Interface”. Korak #3 Odaberite `FPGA' za polje “Chip Select”. Korak #4 Unesite adresu registra, dužinu (uvijek postavljeno na 4) . Korak #5 Kliknite na `Upit' za trenutnu vrijednost prikazanu u polju Sadržaj i `Postavi' za primjenu nove vrijednosti nakon izmjene.
© CrossFire X2RU Korisnički priručnik | 15 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm

4.8. Dual Carrier razmatranja
Neka dodatna razmatranja su potrebna kada se koriste 2 nosioca: 1) Frekvencija Kada se koriste 2 nosioca, postavke frekvencije na GUI su nezavisne za dva nosioca. Ali posebna pažnja se mora posvetiti izbjegavanju preklapanja nosača.
Frekvencija(ARFCN1) Frekvencija(ARFCN0) >= (Bw0 + Bw1) /2

cc0

cc1

bw0

bw1

ARFCN 0

ARFCN 1

Za postavke frekvencije, pronađite parametre prikazane na snimku ispod:

© CrossFire X2RU Korisnički priručnik | 16 od 21

DODATNA SNAGA
62.06dBm Izlazna snaga 2) Postavke pojačanja Uređaj može definirati izlaznu snagu uređaja za downlink konfiguriranjem parametra DL Gain na OMT-u. Uzmite C0
prevoznik kao bivšiampOdgovarajući odnos između izlazne snage downlink-a i DL pojačanja je prikazan na sljedeći način: 46 dBm + ( DL pojačanje (C0) 58 dB ) = DL maksimalna snaga (C0)
Napomena: 58dB je nominalno pojačanje opreme, a 46dBm je nominalna izlazna snaga opreme u nastavku. Kada se koriste 2 nosača, za DL 2 nosioca će dijeliti nazivnu izlaznu snagu od 46dBm.
Ograničenje je: Max_Power(C0) + Max_Power(C1) <= 46 dbm
Možete promijeniti postavke DL pojačanja za nosioce 0 i 1 kako biste zadovoljili gornju jednačinu. Da biste postavili upit za DL Max Power, pronađite odjeljak ispod na stranici sa konfiguracijom operatera.
Sa ispravnim konfiguracijama, informacije o modulu će biti važeće u upitu nakon što se klikne na dugme „Ažuriraj“.
© CrossFire X2RU Korisnički priručnik | 17 od 21

5. Status Monitor
5.1. PTP Status Monitor
1) PTP status

DODATNA SNAGA
Izlazna snaga 62.06dBm

PTP status se može pronaći na stranici Postavke -> Informacije o radio signalu, zeleno svjetlo označava dobar PTP status.
5.2. Monitor napajanja
1) Snaga antene Ulazno/izlazno napajanje antene može se naći na stranici “Postavke -> Informacije o radio signalu”.
2) Snaga u osnovnom pojasu antene Snaga u osnovnom pojasu antene Prenos/prijem na anteni može se provjeriti iz GUI na stranici Postavke -> Informacije o radio signalu. Snaga osnovnog pojasa je prikazana u dBm.

© CrossFire X2RU Korisnički priručnik | 18 od 21

3) Carrier Power Snaga Carrier-a se može naći na stranici “Postavke -> Informacije o streamu”.

DODATNA SNAGA
Izlazna snaga 62.06dBm

Slika iznad prikazuje snagu osnovnog pojasa UL/DL nosioca 0 u dBm.
5.3. Brojači
1) eCPRI brojači Broj U-ravni paketa i C-plane paketa može se pratiti na stranici GUI Održavanje -> Inženjering.

© CrossFire X2RU Korisnički priručnik | 19 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm
6. Alati za održavanje
6.1. Oprema za ručno resetovanje
Uređaj podržava ručno resetovanje na OMT-u, možete pronaći dugme za resetovanje hardvera na stranici GUI Održavanje -> Inženjering.
6.2. MPLANE Timeout Reset
1) Ako je dugme MPLANE Timeout Reset omogućeno U roku od 24 sata nakon pokretanja uređaja, ako CMS platforma nije uspješno povezana, uređaj će se aktivno resetirati u intervalu od sat vremena. Ako je CMS jednom uspješno povezan i nije izvršena operacija resetiranja, CMS prestaje da otkriva vezu i ne pokreće 24-satni mehanizam automatskog resetiranja.
2) Ako je dugme MPLANE Timeout Reset onemogućeno Uređaj ne detektuje vezu sa CMS platformom i ne resetuje uređaj. Stoga, ako se uređaj otklanja greške, savjetujemo vam da onemogućite prekidač.
© CrossFire X2RU Korisnički priručnik | 20 od 21

DODATNA SNAGA
Izlazna snaga 62.06dBm
FCC upozorenje: Ovaj uređaj mora biti profesionalno instaliran.
Imajte na umu da promjene ili modifikacije koje nije izričito odobrila strana odgovorna za usklađenost mogu poništiti korisnikovo ovlaštenje da koristi opremu. Ovaj uređaj je u skladu sa dijelom 15 FCC pravila. Rad je podložan sljedeća dva uslova: (1) Ovaj uređaj ne smije uzrokovati štetne smetnje i (2) Ovaj uređaj mora prihvatiti sve primljene smetnje, uključujući smetnje koje mogu uzrokovati neželjeni rad. Ova oprema je u skladu sa ograničenjima izloženosti zračenju FCC utvrđenim za nekontrolisano okruženje. Ovu opremu treba instalirati i koristiti na minimalnoj udaljenosti od 358.5 cm između radijatora i vašeg tijela.
NAPOMENA: Samo ovlaštena osoba može ući u prostor gdje je antena postavljena. I osoba je potpuno svjesna potencijala za izlaganje i može vršiti kontrolu nad svojom izloženošću napuštanjem područja ili na neki drugi odgovarajući način. Svest o potencijalnom izlaganju radiofrekventnim talasima na radnom mestu ili sličnom okruženju može se obezbediti kroz posebnu obuku kao deo programa bezbednosti RF.
© CrossFire X2RU Korisnički priručnik | 21 od 21