Dostopno stikalo za podatkovne centre serije RG-S6510
“
Tehnični podatki:
Specifikacije strojne opreme:
- Ports Expansion Module Slots:
- RG-S6510-48VS8CQ:
- Two power module slots, supporting 1+1 redundancy
- Four fan module slots, supporting 3+1 redundancy
- RG-S6510-32CQ:
- 32 x 100GE QSFP28 ports
- Two power module slots, supporting 1+1 redundancy
- Five fan module slots, supporting 4+1 redundancy
- RG-S6510-48VS8CQ:
Specifikacije sistema:
- Pristanišče za upravljanje
- Preklopna zmogljivost
- Hitrost posredovanja paketov
- VLAN 802.1Q
Navodila za uporabo izdelka:
1. Data Center Virtualization:
The RG-S6510 series switches support VXLAN to meet data center
overlay networking requirements.
2. Data Center Overlay Networking:
The switches enable the creation of new subnets based on overlay
technology without changing physical topology.
3. DataCenter Layer-2 Network Expansion:
The switch implements RDMA-based Lossless Ethernet for low-delay
forwarding and optimized service performance.
4. Hardware-based Traffic Visualization:
The switch visualizes end-to-end traffic for monitoring
forwarding paths and session delays.
5. Flexible and Complete Security Policies:
The switch supports various security mechanisms for enhanced
zanesljivost.
6. All-Round Management Performance:
The switch supports multiple management ports and SNMP traffic
analysis for network optimization.
Pogosto zastavljena vprašanja (FAQ):
Q: What is the data speed supported by the RG-S6510 series
stikala?
A: The switches support data speeds of up to 25 Gbps/100
Gbps.
Q: What network architecture design requirements do the
switches meet?
A: The switches meet the Spine-Leaf network architecture design
zahteve.
Q: What link reliability mechanisms are integrated into the
stikala?
A: The switches integrate mechanisms like REUP, quick link
switching, GR, and BFD to enhance network reliability.
“`
Tehnični list stikal Ruijie RG-S6510 serije
VSEBINA
konecview…… ...
Kontaktirajte nas
Tel.: +852-63593631 (Hong Kong) E-pošta: sales@network-switch.com (prodajna povpraševanja) ccie-support@network-switch.com (tehnična podpora CCIE)
Network-switch.com
1
KONECVIEW
The RG-S6510 series switches are new-generation switches released by Ruijie Networks for cloud data centers and high-end campuses. They are highlighted by their high performance, high density, and the data speed of up to 25 Gbps/100 Gbps. They meet the Spine-Leaf network architecture design requirements.
VIDEZ
RG-S6510-48VS8CQ Isometric View
RG-S6510-48VS8CQ Isometric View
RG-S6510-32CQ Isometric View
Poudarki izdelka
Neblokirajoča omrežja podatkovnih centrov in zmogljiva medpomnilniška zmogljivost
The whole series of switches oriented towards next- generation data centers and cloud computing are line-rate products. They are in line with the development trend of East-West traffic of data centers and apply to heavy-traffic next-generation data centers. They meet the Spine-Leaf network architecture design requirements. The RG-S6510 series switches provide 48 × 25GE ports and 8 × 100GE ports or 32 × 100GE ports. All the ports can forward data at the line rate. The 100GE ports are backward compatible with 40GE ports. To meet the requirements for non-blocking transmission of heavy-traffic data in data centers, the switch offers powerful buffer capacity and uses the advanced buffer scheduling mechanism, to ensure that the buffer capacity of the switch is effectively leveraged.
Network-switch.com
2
Virtualizacija podatkovnih centrov
The RG-S6510 series switches adopt the virtual switching unit (VSU) 2.0 technology to virtualize multiple physical devices into one logical device, which reduces network nodes and enhances network reliability. These physical switches can be operated and managed in a unified manner. The switch can implement fast link switching within 50 ms to 200 ms in the case of a link failure, thereby ensuring the uninterrupted transmission of key services. The inter-device link aggregation feature implements dual active uplinks for data through access servers and switches..
Data Center Overlay Networking
The RG-S6510 series switches support VXLAN to meet the data center overlay networking requirements. This addresses the difficulty to expand traditional data center networks due to VLAN limit. The basic network built by the RG-S6510 series switches can be divided into new subnets based on the overlay technology, without changing the physical topology or considering the restrictions on IP addresses and broadcast domains of physical networks.
DataCenter Layer-2 Network Expansion
The VXLAN technology encapsulates layer-2 packets into User Datagram Protocol (UDP) packets, which enables the establishment of a logically layer-2 network on the layer-3 network. The RG-S6510 series switches support the EVPN protocol to automatically discover and authenticate virtual tunnel endpoints (VTEPs), thereby reducing flooding on the VXLAN data plane and preventing VXLAN from relying on deployed underlying multicast services. This simplifies VXLAN deployment and improves the large layer-2 network building efficiency to better meet the requirements of deploying a large layer-2 network in data centers.
Brezizgubni Ethernet na osnovi RDMA
Stikalo omogoča posredovanje brezizgubnega Etherneta z nizko zakasnitvijo na podlagi oddaljenega neposrednega dostopa do pomnilnika (RDMA) in optimizira delovanje posredovanja storitev. To močno zmanjša obratovalne stroške na bit celotnega omrežja in poveča konkurenčno prednost izdelkov.
Vizualizacija prometa s strojno opremo
Strojna oprema čipa omogoča stikalu vizualizacijo prometa od konca do konca v kompleksnih omrežjih, ki vključujejo več poti in vozlišč. Uporabniki se lahko nato osredotočijo na spremljanje poti posredovanja in zakasnitve posamezne seje, kar dramatično poveča učinkovitost odpravljanja težav.
Network-switch.com
3
Carrier-Class Reliability Protection The RG-S6510 series switches are equipped with built- in redundant power supply modules and modular fan assemblies. All power supply modules and fan modules can be hot-swapped without affecting the normal running of the device. The switch provides fault detection and alarm functions for power supply modules and fan modules. It automatically adjusts the fan speed based on temperature changes, to better adapt to the environment in data centers. The switch also supports device-level and link-level reliability protection as well as overcurrent protection, overvoltage protection, and overheating protection.
In addition, the switch integrates various link reliability mechanisms, such as Rapid Ethernet Uplink Protection Protocol (REUP), quick link switching, graceful restart (GR), and bidirectional forwarding detection (BFD). When multiple services and heavy traffic are carried over the network, these mechanisms can reduce the impact of exceptions on network services and enhance overall reliability.
IPv4/IPv6 Dual-Stack Protocols and Multilayer Switching The hardware of the RG-S6510 series switches supports IPv4 and IPv6 protocol stacks and multilayer line-rate switching. The hardware differentiates and processes IPv4 and IPv6 packets. The switch also integrates multiple tunneling technologies such as manually configured tunnels, automatic tunnels, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunnels. Users can flexibly work out IPv6 inter-network communication solutions by using this switch based on IPv6 network planning and network conditions. The RG-S6510 series switches support numerous IPv4 routing protocols, including static routing, Routing Information Protocol (RIP), Open Shortest Path First (OSPF), Intermediate System to Intermediate System (IS- IS), and Border Gateway Protocol version 4 (BGP4). Users can select required routing protocols based on network environments, to flexibly build networks. The RG-S6510 series switches also support abundant IPv6 routing protocols, including static routing, Routing Information Protocol next generation (RIPng), OSPFv3, and BGP4+. Appropriate routing protocols can be selected to upgrade an existing network to an IPv6 network or build a new IPv6 network.
Network-switch.com
4
Prilagodljive in celovite varnostne politike
Stikala serije RG-S6510 učinkovito branijo pred širjenjem virusov in hekerskimi napadi ter jih nadzorujejo z uporabo več inherentnih mehanizmov, kot so napadi proti DoS, skeniranje IP-jev, preverjanje veljavnosti ARP paketov na vratih in več pravilnikov strojne kontrole dostopa (ACL). Strojna kontrola dostopa IPv6 lahko enostavno nadzoruje dostop uporabnikov IPv6 na meji omrežja, tudi če so uporabniki IPv6 prisotni v omrežju IPv4. Stikalo podpira sobivanje uporabnikov IPv4 in IPv6 ter lahko nadzoruje dovoljenja za dostop uporabnikov IPv6, npr.ampomejuje dostop do občutljivih virov v omrežju. Nadzor dostopa Telnet na podlagi izvornih IP naslovov lahko prepreči zlonamerne napade in nadzor stikala s strani nezakonitih uporabnikov in hekerjev, s čimer se izboljša varnost upravljanja omrežja. Varna lupina (SSH) in protokol Simple Network Management Protocol različice 3 (SNMPv3) lahko šifrirata upravljalne podatke v procesih Telnet in SNMP, s čimer zagotovita varnost informacij stikala in preprečita hekerjem napad in nadzor stikala. Stikalo zavrača dostop do omrežja nezakonitih uporabnikov in omogoča zakonitim uporabnikom pravilno uporabo omrežij z uporabo večelementnega vezanja, varnosti vrat, časovno omejenega ACL in omejitve hitrosti pretoka podatkov. Strogo lahko nadzoruje dostop uporabnikov do poslovnih omrežij in ...ampameriških omrežjih in omejiti komunikacijo nepooblaščenih uporabnikov.
Vsestranska uspešnost upravljanja
The switch supports various management ports, such as the console port, management port, and USB port, and supports the SNMP traffic analysis report to help users optimize the network structure and adjust resource deployment in a timely manner.
Tehnične specifikacije
Specifikacije strojne opreme
Sistemske specifikacije
Sistemske specifikacije
RG-S6510-48VS8CQ
Vrata Reže za razširitvene module
48 x 25GE SFP28 ports and 8 × 100GE QSFP28 ports
Two power module slots, supporting 1+1 redundancy Four fan module slots, supporting 3+1 redundancy
RG-S6510-32CQ
32 x 100GE QSFP28 ports
Two power module slots, supporting 1+1 redundancy Five fan module slots, supporting 4+1 redundancy
Network-switch.com
5
System Specifications Management Port Switching Capacity Packet Forwarding Rate 802.1Q VLAN
RG-S6510-48VS8CQ
RG-S6510-32CQ
One management port, one console port, and one USB port, compliant with the USB2.0 standard
4.0 Tbps
6.4 Tbps
2000 Mpps
2030 Mpps
4094
Dimenzije
Dimensions and Weight Dimensions (W × D × H)
Teža
RG-S6510-48VS8CQ
RG-S6510-32CQ
442 mm x 387 mm x 44 mm (17.40 palca x 15.24 palca x 1.73 palca, 1 RU)
About 8.2 kg (18.08 lbs., including two power supply modules and four fan modules)
442 mm x 560 mm x 44 mm (17.40 palca x 22.05 palca x 1.73 palca, 1 RU)
About 11.43 kg (25.20 lbs., including two power supply modules and five fan modules)
Napajanje in poraba
Napajanje in poraba
RG-S6510-48VS8CQ
RG-S6510-32CQ
AC High-voltage DC Low-voltage DC
Največja poraba energije
Nazivna voltage: 110 V AC/220 V AC
Nazivna voltage range: 100 V AC to 240 V AC (50 Hz to 60 Hz)
Največja glasnosttage range: 90 V AC to 264 V AC (47 Hz to 63 Hz)
Nazivno območje vhodnega toka: od 3.5 A do 7.2 A
Vhodna voltage range: 192 V DC to 288 V DC
Vhodni tok: 3.6 A
Vhodna voltage range: 36 V DC to 72 V
DC
N/A
Nazivna vhodna voltage: 48 V DC
Rated input current: 23 A Max: 300 W
Največ: 450 W
Običajno: 172 W
Običajno: 270 W
Static: 98 W
Static: 150 W
Okolje in zanesljivost
Okolje in zanesljivost
RG-S6510-48VS8CQ
Delovna temperatura
0 °C do 45 °C (32 °F do 113 °F)
RG-S6510-32CQ 0°C to 40°C (32ºF to 104ºF)
Network-switch.com
6
Okolje in zanesljivost
RG-S6510-48VS8CQ
Storage temperature Operating Humidity Storage humidity
Delovna višina
-40 °C to 70 °C (-40 °F to 158 °F) 10%RH to 90% RH (Non-condensing)
5 % do 95 % RH (brez kondenzacije)
Delovna nadmorska višina: do 5000 m (16,404.20 čevljev). Nadmorska višina shranjevanja: do 5000 m (16,404.20 čevljev).
RG-S6510-32CQ
Specifikacije programske opreme
Specifikacije programske opreme
RG-S6510-48VS8CQ
RG-S6510-32CQ
Protokoli L2
IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and Selective QinQ), GVRP
L3 Protocols (IPv4)
BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/ DM, MSDP, Any-RP
IPv6 Basic Protocols IPv6 Features Multicast
Odkrivanje sosedov, ICMPv6, odkrivanje MTU poti, DNSv6, DHCPv6, ICMPv6, preusmeritev ICMPv6, ACLv6, TCP/UDP za IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, podpora za IPv6 MIB za SNMP, VRRP za IPv6, IPv6 QoS
Statično usmerjanje, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, ročni tunel, samodejni tunel, tunel IPv4 prek IPv6 in tunel ISATAP
IGMPv1, v2, v3 IGMP Host Behavior Member Query and Response Querier Election IGMP ProxyMulticast Static Routing MSDPPIM-DMPIM-SM PIM-SSM Enabling PIM on Layer-3 SubinterfacePIM-SMv6 MLD v1 and v2MLD Proxy Enabling PIMv6 on Layer-3 Subinterface
Standard IP-based ACL Extended MAC/IP-based ACL Expert-level ACL ACL 80 IPv6
ACL ACL Logging ACL Counter (Ingress and egress counters are supported in interface or global configuration modes) ACL Re-marking Global ACL ACL-based
Redirection Displaying ACL Resources Processing First Packet of TCP Handshake
When Binding the ACL to Restrict SIP
Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets The expert-level ACL
ACL
supports matching the IP flag and DSCP fields of VXLAN inner packets Ingress/Egress
ACL-ji
When the same ACL is applied to different
physical interfaces or SVIs, resources can
be multiplexed
N/A
Network-switch.com
7
Software Specifications Data Center Features
RG-S6510-48VS8CQ
RG-S6510-32CQ
VXLAN routing and VXLAN bridging
IPv6 VXLAN over IPv4 and EVPN VXLAN PFC, ECN, and RDMA M-LAG
*RoCE over VxLAN OpenFlow 1.3
Vizualizacija
QoS Virtualization Buffer Management HA Design
Varnostne funkcije Način upravljanja Drugi protokoli
gRPC sFLOW sampling INT
Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding
Virtualna preklopna enota
Spremljanje in upravljanje stanja medpomnilnika ter identifikacija nenadnega prometa
GR za RIP/OSPF/BGP, BFD, DLDP, hitro preklapljanje z dvojno povezavo REUP, zaznavanje enosmerne povezave RLDP, redundanco napajanja 1+1 in redundanco ventilatorjev ter vročo zamenjavo za vse kartice in napajalne module.
Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management
SNMP v1/v2c/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, Python, fan and power alarm, and temperature alarm DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog
Varnost in skladnost s predpisi
Specifikacija
RG-S6510-48VS8CQ
RG-S6510-32CQ
Varnost
IEC 62368-1 EN 62368-1 NM EN 62368-1 NM CEI 62368-1 EN IEC 62368-1 BS EN IEC 62368-1 UL 62368-1 CSA C22.2#62368-1 GB 4943.1
IEC 62368-1 EN 62368-1 EN IEC 62368-1 UL 62368-1 CAS C22.2#62368-1 GB 4943.1
Network-switch.com
8
Specifikacija
RG-S6510-48VS8CQ
RG-S6510-32CQ
Elektromagnetna združljivost (EMC)
okolje
EN 55032 EN 55035 EN IEC 61000-3-2 EN IEC 61000-3-3 EN 61000-3-3 EN 300 386 ETSI EN 300 386 NM EN 55035 NM EN CEI61000-3-2 NM EN 61000-3-3 CNS 13438 ICES-003 Issue 7 ANSI C63.4-2014 FCC CFR Title 47, Part 15, Subpart B ANSI C63.4-2014 VCCI-CLSPR 32 GB/T 9254.1 2011/65/EU EN 50581 2012/19/EU EN 50419 (EC) No.1907/2006 GB/T 26572
EN 55032 EN 55035 EN 61000-3-2 EN 61000-3-3 EN IEC 61000-3-3 EN IEC 61000-3-2 EN 300 386 ETSI EN 300 386 CES-003 Issue 7 ANSI C63.4-2014 FCC CFR Title 47, Part 15,Subpart B VCCI-CISPR 32 GB/T 9254.1
2011/65/EU EN 50581 2012/19/EU EN 50419 (ES) št. 1907/2006 GB/T 26572
Priročnik za konfiguracijo
Postopek konfiguracije stikal serije RG-S6510 je naslednji:
*Select the switch based on the port types and quantity required by the service. *Select the fan and power supply modules based on the switch model. *Select optical transceivers based on port requirements.
NETWORK-SWITCH.COM INFORMACIJE ZA NAROČANJE
Šasija
Product Model RG-S6510-48VS8CQ
RG-S6510-32CQ
Opis
48 × 25GE ports and 8 × 100GE ports. Two power supply module slots and four fan module slots. The power module model is RG-PA550I-F, and the fan model is M6510-FAN-F.
Provides 32 × 100G ports. Two power supply module slots and five fan module slots. The power module model is RG-PA550I-F, and the fan model is M1HFAN I-F.
Network-switch.com
9
Fan and Power Supply Modules
Product Model RG-PA550I-F
Description 550 W power supply module (AC and 240 V HVDC)
RG-PD800I-F M6510-FAN-F
800 W power supply module (48 V LVDC), applicable only to RG-S6510-48VS8CQ
Fan module of RG-S6510-48VS8CQ and RG-S6510-48VS8CQ-X, supporting 3+1 redundancy, hot swapping, and front-to-rear ventilation design.
Optični moduli serije 100G BASE
Model izdelka
Opis
100G-QSFP-SR-MM850 100G-QSFP-LR4-SM1310 100G-QSFP-iLR4-SM1310 100G-QSFP-ER4-SM1310 100G-AOC-10M 100G-AOC-5M
100G SR modul, faktor oblike QSFP28, MPO, 850 nm, 100 m (328.08 ft) preko MMF
Modul 100G LR4, oblika QSFP28, dupleksni LC, 1310 nm, 10 km (32,808.40 čevljev) prek SMF Modul 100G iLR4, oblika QSFP28, dupleksni LC, 1310 nm, 2 km (6,561.68 čevljev) prek SMF
Modul 100G ER4, faktor oblike QSFP28, dupleks LC, 1310 nm, 40 km (131,233.59 čevljev) prek kabla SMF 100G QSFP28 AOC, 10 m (32.81 čevljev)
Kabel 100G QSFP28 AOC, 5 m (16.40 čevljev)
Optični moduli serije 40G BASE
Model izdelka
Opis
40G-QSFP-SR-MM850 40G-QSFP-LR4-SM1310 40G-QSFP-LSR-MM850 40G-QSFP-iLR4-SM1310
40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF 40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF 40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF 40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF
40G-QSFP-LX4-SM1310 40G-AOC-30M 40G-AOC-5M
40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF 40G QSFP+ AOC cable, 30 m (98.43 ft.)
40G QSFP+ AOC cable, 5 m (16.40 ft.)
Network-switch.com
10
Optični moduli serije 25G BASE
Model izdelka
Opis
VG-SFP-AOC5M VG-SFP-LR-SM1310 VG-SFP-SR-MM850
25G SFP28 AOC cable, 5 m (16.40 ft.) 25G LR module, SFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF 25G SR module, SFP28 form factor, Duplex LC, 850 nm, 100 m (328.08 ft.) over MMF
Optični moduli serije 10G BASE
Model izdelka
Opis
XG-LR-SM1310 XG-SR-MM850 XG-SFP-AOC1M XG-SFP-AOC3M
10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF 10G SFP+ AOC cable, 1 m (3.28 ft.) 10G SFP+ AOC cable, 3 m (9.84 ft.)
XG-SFP-AOC5M XG-SFP-SR-MM850 XG-SFP-LR-SM1310 XG-SFP-ER-SM1550 XG-SFP-ZR-SM1550
10G SFP+ AOC cable, 5 m (16.40 ft.) 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF 10G ER module, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF 10G ZR module, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF
1000M BASE Series Optical Modules
Model izdelka
Opis
GE-SFP-LH40-SM1310-BIDI GE-SFP-LX20-SM1310-BIDI GE-SFP-LX20-SM1550-BIDI
1G LH module, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF
Network-switch.com
11
MINI-GBIC-LH40-SM1310 MINI-GBIC-LX-SM1310 MINI-GBIC-SX-MM850 MINI-GBIC-ZX80-SM1550
1G LH module, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF 1G LX module, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF 1G SR module, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF 1G ZX module, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF
1000M BASE Series Electrical Modules
Model izdelka
Opis
Mini-GBIC-GT(F) Mini-GBIC-GT
1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a 1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a
Network-switch.com
12
Dokumenti / Viri
![]() |
Ruijie-networks RG-S6510 Series Data Center Access Switch [pdf] Navodila za uporabo RG-S6510-48VS8CQ, RG-S6510-32CQ, RG-S6510 Series Data Center Access Switch, RG-S6510 Series, Data Center Access Switch, Center Access Switch, Access Switch |