Ruijie-netwerke RG-S6510-reeks datasentrumtoegangskakelaar-instruksiehandleiding

RG-S6510-reeks datasentrumtoegangskakelaar

Spesifikasies:

Hardeware spesifikasies:

  • Ports Expansion Module Slots:
    • RG-S6510-48VS8CQ:
      • Two power module slots, supporting 1+1 redundancy
      • Four fan module slots, supporting 3+1 redundancy
    • RG-S6510-32CQ:
      • 32 x 100GE QSFP28 ports
      • Two power module slots, supporting 1+1 redundancy
      • Five fan module slots, supporting 4+1 redundancy

Stelsel spesifikasies:

  • Bestuurshawe
  • Skakelkapasiteit
  • Pakkie-aanstuurkoers
  • 802.1Q VLAN

Produkgebruiksinstruksies:

1. Data Center Virtualization:

The RG-S6510 series switches support VXLAN to meet data center
overlay networking requirements.

2. Data Center Overlay Networking:

The switches enable the creation of new subnets based on overlay
technology without changing physical topology.

3. DataCenter Layer-2 Network Expansion:

The switch implements RDMA-based Lossless Ethernet for low-delay
forwarding and optimized service performance.

4. Hardware-based Traffic Visualization:

The switch visualizes end-to-end traffic for monitoring
forwarding paths and session delays.

5. Flexible and Complete Security Policies:

The switch supports various security mechanisms for enhanced
betroubaarheid.

6. All-Round Management Performance:

The switch supports multiple management ports and SNMP traffic
analysis for network optimization.

Gereelde Vrae (Gereelde Vrae):

Q: What is the data speed supported by the RG-S6510 series
skakelaars?

A: The switches support data speeds of up to 25 Gbps/100
Gbps.

Q: What network architecture design requirements do the
switches meet?

A: The switches meet the Spine-Leaf network architecture design
vereistes.

Q: What link reliability mechanisms are integrated into the
skakelaars?

A: The switches integrate mechanisms like REUP, quick link
switching, GR, and BFD to enhance network reliability.

"`

Ruijie RG-S6510-reeks skakelaar-datablad

INHOUD
verbyview……………………………………………………………………………………………………………………………………..2 Voorkoms …………………………………………………………………………………………………………………………………………2 Produkhoogtepunte ………………………………………………………………………………………………………………………………2 Spesifikasies ………………………………………………………………………………………………………………………………5 Konfigurasiegids…………………………………………………………………………………………………………………………..9 Bestelinligting…………………………………………………………………………………………………………………………………….9

Kontak ons
Tel: +852-63593631 (Hong Kong) E-pos: sales@network-switch.com (Verkoopsnavrae) ccie-support@network-switch.com (CCIE Tegniese Ondersteuning)

Netwerkskakelaar.com

1

VERBYVIEW
The RG-S6510 series switches are new-generation switches released by Ruijie Networks for cloud data centers and high-end campuses. They are highlighted by their high performance, high density, and the data speed of up to 25 Gbps/100 Gbps. They meet the Spine-Leaf network architecture design requirements.
VOORKOMS

RG-S6510-48VS8CQ Isometric View

RG-S6510-48VS8CQ Isometric View

RG-S6510-32CQ Isometric View

Produk hoogtepunte
Nie-blokkerende datasentrumnetwerke en kragtige bufferkapasiteit
The whole series of switches oriented towards next- generation data centers and cloud computing are line-rate products. They are in line with the development trend of East-West traffic of data centers and apply to heavy-traffic next-generation data centers. They meet the Spine-Leaf network architecture design requirements. The RG-S6510 series switches provide 48 × 25GE ports and 8 × 100GE ports or 32 × 100GE ports. All the ports can forward data at the line rate. The 100GE ports are backward compatible with 40GE ports. To meet the requirements for non-blocking transmission of heavy-traffic data in data centers, the switch offers powerful buffer capacity and uses the advanced buffer scheduling mechanism, to ensure that the buffer capacity of the switch is effectively leveraged.

Netwerkskakelaar.com

2

Datasentrum-virtualisering
The RG-S6510 series switches adopt the virtual switching unit (VSU) 2.0 technology to virtualize multiple physical devices into one logical device, which reduces network nodes and enhances network reliability. These physical switches can be operated and managed in a unified manner. The switch can implement fast link switching within 50 ms to 200 ms in the case of a link failure, thereby ensuring the uninterrupted transmission of key services. The inter-device link aggregation feature implements dual active uplinks for data through access servers and switches..
Data Center Overlay Networking
The RG-S6510 series switches support VXLAN to meet the data center overlay networking requirements. This addresses the difficulty to expand traditional data center networks due to VLAN limit. The basic network built by the RG-S6510 series switches can be divided into new subnets based on the overlay technology, without changing the physical topology or considering the restrictions on IP addresses and broadcast domains of physical networks.
DataCenter Layer-2 Network Expansion
The VXLAN technology encapsulates layer-2 packets into User Datagram Protocol (UDP) packets, which enables the establishment of a logically layer-2 network on the layer-3 network. The RG-S6510 series switches support the EVPN protocol to automatically discover and authenticate virtual tunnel endpoints (VTEPs), thereby reducing flooding on the VXLAN data plane and preventing VXLAN from relying on deployed underlying multicast services. This simplifies VXLAN deployment and improves the large layer-2 network building efficiency to better meet the requirements of deploying a large layer-2 network in data centers.
RDMA-gebaseerde verlieslose Ethernet
Die skakelaar implementeer lae-vertraging aanstuur van die verlieslose Ethernet gebaseer op die Remote Direct Memory Access (RDMA) en optimaliseer diensaanstuurprestasie. Dit verminder die bedryfskoste per bit van die hele netwerk aansienlik en verbeter die mededingende voordeel van produkte.
Hardeware-gebaseerde Verkeersvisualisering
Die skyfie-hardeware stel die skakelaar in staat om die end-tot-end verkeer van komplekse netwerke wat verskeie paaie en nodusse behels, te visualiseer. Dan kan gebruikers fokus op die monitering van die aanstuurpad en vertraging van elke sessie, wat die probleemoplossingsdoeltreffendheid dramaties verhoog.

Netwerkskakelaar.com

3

Carrier-Class Reliability Protection The RG-S6510 series switches are equipped with built- in redundant power supply modules and modular fan assemblies. All power supply modules and fan modules can be hot-swapped without affecting the normal running of the device. The switch provides fault detection and alarm functions for power supply modules and fan modules. It automatically adjusts the fan speed based on temperature changes, to better adapt to the environment in data centers. The switch also supports device-level and link-level reliability protection as well as overcurrent protection, overvoltage protection, and overheating protection.
In addition, the switch integrates various link reliability mechanisms, such as Rapid Ethernet Uplink Protection Protocol (REUP), quick link switching, graceful restart (GR), and bidirectional forwarding detection (BFD). When multiple services and heavy traffic are carried over the network, these mechanisms can reduce the impact of exceptions on network services and enhance overall reliability.
IPv4/IPv6 Dual-Stack Protocols and Multilayer Switching The hardware of the RG-S6510 series switches supports IPv4 and IPv6 protocol stacks and multilayer line-rate switching. The hardware differentiates and processes IPv4 and IPv6 packets. The switch also integrates multiple tunneling technologies such as manually configured tunnels, automatic tunnels, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunnels. Users can flexibly work out IPv6 inter-network communication solutions by using this switch based on IPv6 network planning and network conditions. The RG-S6510 series switches support numerous IPv4 routing protocols, including static routing, Routing Information Protocol (RIP), Open Shortest Path First (OSPF), Intermediate System to Intermediate System (IS- IS), and Border Gateway Protocol version 4 (BGP4). Users can select required routing protocols based on network environments, to flexibly build networks. The RG-S6510 series switches also support abundant IPv6 routing protocols, including static routing, Routing Information Protocol next generation (RIPng), OSPFv3, and BGP4+. Appropriate routing protocols can be selected to upgrade an existing network to an IPv6 network or build a new IPv6 network.

Netwerkskakelaar.com

4

Buigsame en volledige sekuriteitsbeleide
Die RG-S6510-reeks skakelaars verdedig effektief teen en beheer virusverspreiding en hacker-aanvalle deur verskeie inherente meganismes te gebruik, soos anti-DoS-aanval, anti-IP-skandering, geldigheidskontrole van ARP-pakkette op poorte en verskeie hardeware ACL-beleide. Die hardeware-gebaseerde IPv6 ACL kan maklik die toegang van IPv6-gebruikers by die netwerkgrens beheer, selfs al is daar IPv6-gebruikers op 'n IPv4-netwerk. Die skakelaar ondersteun die naasbestaan van IPv4- en IPv6-gebruikers en kan toegangsregte van IPv6-gebruikers beheer, byvoorbeeld.ample, wat toegang tot sensitiewe hulpbronne op die netwerk beperk. Die telnet-toegangsbeheer gebaseer op bron-IP-adresse kan verhoed dat onwettige gebruikers en hackers die skakelaar kwaadwillig aanval en beheer, wat netwerkbestuursekuriteit verbeter. Die Secure Shell (SSH) en Simple Network Management Protocol weergawe 3 (SNMPv3) kan bestuursinligting in die telnet- en SNMP-prosesse enkripteer, waardeur die inligtingsekuriteit van die skakelaar verseker word en hackers verhoed word om die skakelaar aan te val en te beheer. Die skakelaar verwerp netwerktoegang van onwettige gebruikers en stel wettige gebruikers in staat om netwerke behoorlik te gebruik deur multi-elementbinding, poortsekuriteit, tydgebaseerde ACL en datastroomgebaseerde tempolimiet te gebruik. Dit kan gebruikerstoegang tot ondernemingsnetwerke streng beheer en campons netwerke en beperk die kommunikasie van ongemagtigde gebruikers.
Algehele Bestuursprestasie
The switch supports various management ports, such as the console port, management port, and USB port, and supports the SNMP traffic analysis report to help users optimize the network structure and adjust resource deployment in a timely manner.

Tegniese spesifikasies
Hardeware spesifikasies
Stelsel spesifikasies
Stelsel spesifikasies

RG-S6510-48VS8CQ

Poortuitbreidingsmodule-gleuwe

48 x 25GE SFP28 ports and 8 × 100GE QSFP28 ports
Two power module slots, supporting 1+1 redundancy Four fan module slots, supporting 3+1 redundancy

RG-S6510-32CQ
32 x 100GE QSFP28 ports
Two power module slots, supporting 1+1 redundancy Five fan module slots, supporting 4+1 redundancy

Netwerkskakelaar.com

5

System Specifications Management Port Switching Capacity Packet Forwarding Rate 802.1Q VLAN

RG-S6510-48VS8CQ

RG-S6510-32CQ

One management port, one console port, and one USB port, compliant with the USB2.0 standard

4.0 Tbps

6.4 eetlepels

2000 Mpps

2030 Mpps

4094

Afmetings
Dimensions and Weight Dimensions (W × D × H)
Gewig

RG-S6510-48VS8CQ

RG-S6510-32CQ

442 mm x 387 mm x 44 mm (17.40 duim x 15.24 duim x 1.73 duim, 1 RU)
About 8.2 kg (18.08 lbs., including two power supply modules and four fan modules)

442 mm x 560 mm x 44 mm (17.40 duim x 22.05 duim x 1.73 duim, 1 RU)
About 11.43 kg (25.20 lbs., including two power supply modules and five fan modules)

Kragvoorsiening en verbruik

Kragvoorsiening en verbruik

RG-S6510-48VS8CQ

RG-S6510-32CQ

AC High-voltage DC Low-voltage DC
Maksimum kragverbruik

Gegradeerde voltage: 110 V WS/220 V WS

Gegradeerde voltage range: 100 V AC to 240 V AC (50 Hz to 60 Hz)

Maks. Voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz)

Gegradeerde invoerstroombereik: 3.5 A tot 7.2 A

Invoer voltage range: 192 V DC to 288 V DC

Insetstroom: 3.6 A

Invoer voltage range: ­36 V DC to ­72 V

DC

NVT

Gegradeerde invoer voltage: ­48 V DC

Rated input current: 23 A Max: 300 W

Max: 450 W

Tipies: 172 W

Tipies: 270 W

Static: 98 W

Static: 150 W

Omgewing en betroubaarheid
Omgewing en betroubaarheid

RG-S6510-48VS8CQ

Bedryfstemperatuur

0°C tot 45°C (32°F tot 113°F)

RG-S6510-32CQ 0°C to 40°C (32ºF to 104ºF)

Netwerkskakelaar.com

6

Omgewing en betroubaarheid

RG-S6510-48VS8CQ

Storage temperature Operating Humidity Storage humidity
Werkshoogte

-40 °C to 70 °C (-40 °F to 158 °F) 10%RH to 90% RH (Non-condensing)
5% tot 95% RH (nie-kondenserend)
Bedryfshoogte: tot 5000 m (16,404.20 5000 vt.) Bergingshoogte: tot 16,404.20 m (XNUMX XNUMX vt.)

RG-S6510-32CQ

Sagteware spesifikasies
Sagteware spesifikasies

RG-S6510-48VS8CQ

RG-S6510-32CQ

L2-protokolle

IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (QinQ and Selective QinQ), GVRP

L3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing (PBR), Route-policy, Equal-Cost Multi-Path Routing (ECMP), WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/ DM, MSDP, Any-RP

IPv6 Basic Protocols IPv6 Features Multicast

Buurontdekking, ICMPv6, Pad MTU-ontdekking, DNSv6, DHCPv6, ICMPv6, ICMPv6-herleiding, ACLv6, TCP/UDP vir IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB-ondersteuning vir SNMP, VRRP vir IPv6, IPv6 QoS
Statiese roetering, ECMP, PBR, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, handmatige tonnel, outomatiese tonnel, IPv4 oor IPv6-tonnel en ISATAP-tonnel
IGMPv1, v2, v3 IGMP Host Behavior Member Query and Response Querier Election IGMP ProxyMulticast Static Routing MSDPPIM-DMPIM-SM PIM-SSM Enabling PIM on Layer-3 SubinterfacePIM-SMv6 MLD v1 and v2MLD Proxy Enabling PIMv6 on Layer-3 Subinterface

Standard IP-based ACL Extended MAC/IP-based ACL Expert-level ACL ACL 80 IPv6

ACL ACL Logging ACL Counter (Ingress and egress counters are supported in interface or global configuration modes) ACL Re-marking Global ACL ACL-based

Redirection Displaying ACL Resources Processing First Packet of TCP Handshake

When Binding the ACL to Restrict SIP

Matching Against 5-Tuple of Pass-by VXLAN Inner IP Packets The expert-level ACL

ACL

supports matching the IP flag and DSCP fields of VXLAN inner packets Ingress/Egress

ACL's

When the same ACL is applied to different

physical interfaces or SVIs, resources can

be multiplexed

NVT

Netwerkskakelaar.com

7

Software Specifications Data Center Features

RG-S6510-48VS8CQ

RG-S6510-32CQ

VXLAN routing and VXLAN bridging
IPv6 VXLAN over IPv4 and EVPN VXLAN PFC, ECN, and RDMA M-LAG
*RoCE over VxLAN OpenFlow 1.3

Visualisering
QoS Virtualization Buffer Management HA Design
Sekuriteitskenmerke Bestuursmodus Ander Protokolle

gRPC sFLOW sampling INT
Mapping of IEEE 802.1p, DSCP, and ToS priorities ACL-based traffic classification Priority marking/remarking Multiple queue scheduling mechanisms, including SP, WRR, DRR, SP+WRR, and SP+DRR Congestion avoidance mechanisms such as WRED and tail discarding
Virtuele skakeleenheid
Bufferstatusmonitering en -bestuur, en identifisering van barsverkeer
GR vir RIP/OSPF/BGP, BFD, DLDP, REUP dubbelskakel-vinnige skakeling, RLDP-unidireksionele skakelopsporing, 1+1 kragredundansie en waaierredundansie, en warm ruiling vir alle kaarte en kragtoevoermodules
Network Foundation Protection Policy (NFPP), CPP, DDoS attack defense, illegitimate data packet detection, data encryption, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 ciphertext-based authentication for OSPF, RIPv2, and BGPv4 packets, telnet login and password mechanisms for restricted IP addresses, uRPF, broadcast packet suppression, DHCP Snooping, ARP spoofing prevention, ARP check, and hierarchical user management
SNMP v1/v2c/v3, Netconf, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP clock, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, Python, fan and power alarm, and temperature alarm DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP relay, ARP Proxy, and Syslog

Veiligheid en regulatoriese nakoming

Spesifikasie

RG-S6510-48VS8CQ

RG-S6510-32CQ

Veiligheid

IEC 62368-1 EN 62368-1 NM EN 62368-1 NM CEI 62368-1 EN IEC 62368-1 BS EN IEC 62368-1 UL 62368-1 CSA C22.2#62368-1 GB 4943.1

IEC 62368-1 EN 62368-1 EN IEC 62368-1 UL 62368-1 CAS C22.2#62368-1 GB 4943.1

Netwerkskakelaar.com

8

Spesifikasie

RG-S6510-48VS8CQ

RG-S6510-32CQ

Elektromagnetiese versoenbaarheid (EMC)
Omgewing

EN 55032 EN 55035 EN IEC 61000-3-2 EN IEC 61000-3-3 EN 61000-3-3 EN 300 386 ETSI EN 300 386 NM EN 55035 NM EN CEI61000-3-2 NM EN 61000-3-3 CNS 13438 ICES-003 Issue 7 ANSI C63.4-2014 FCC CFR Title 47, Part 15, Subpart B ANSI C63.4-2014 VCCI-CLSPR 32 GB/T 9254.1 2011/65/EU EN 50581 2012/19/EU EN 50419 (EC) No.1907/2006 GB/T 26572

EN 55032 EN 55035 EN 61000-3-2 EN 61000-3-3 EN IEC 61000-3-3 EN IEC 61000-3-2 EN 300 386 ETSI EN 300 386 CES-003 Issue 7 ANSI C63.4-2014 FCC CFR Title 47, Part 15,Subpart B VCCI-CISPR 32 GB/T 9254.1
2011/65/EU EN 50581 2012/19/EU EN 50419 (EC) No.1907/2006 GB/T 26572

Konfigurasiegids
Die konfigurasieprosedure vir die RG-S6510-reeks skakelaars is soos volg:
*Select the switch based on the port types and quantity required by the service. *Select the fan and power supply modules based on the switch model. *Select optical transceivers based on port requirements.

NETWERK-SKAKEL.COM BESTELLINGSINLIGTING

Onderstel
Product Model RG-S6510-48VS8CQ
RG-S6510-32CQ

Beskrywing
48 × 25GE ports and 8 × 100GE ports. Two power supply module slots and four fan module slots. The power module model is RG-PA550I-F, and the fan model is M6510-FAN-F.
Provides 32 × 100G ports. Two power supply module slots and five fan module slots. The power module model is RG-PA550I-F, and the fan model is M1HFAN I-F.

Netwerkskakelaar.com

9

Fan and Power Supply Modules

Product Model RG-PA550I-F

Description 550 W power supply module (AC and 240 V HVDC)

RG-PD800I-F M6510-FAN-F

800 W power supply module (48 V LVDC), applicable only to RG-S6510-48VS8CQ
Fan module of RG-S6510-48VS8CQ and RG-S6510-48VS8CQ-X, supporting 3+1 redundancy, hot swapping, and front-to-rear ventilation design.

100G BASE-reeks optiese modules
Produk Model

Beskrywing

100G-QSFP-SR-MM850 100G-QSFP-LR4-SM1310 100G-QSFP-iLR4-SM1310 100G-QSFP-ER4-SM1310 100G-AOC-10M 100G-AOC-5M

100G SR-module, QSFP28-vormfaktor, MPO, 850 nm, 100 m (328.08 vt.) oor MMF
100G LR4-module, QSFP28-vormfaktor, Dupleks LC, 1310 nm, 10 km (32,808.40 100 vt.) oor SMF 4G iLR28-module, QSFP1310-vormfaktor, Dupleks LC, 2 nm, 6,561.68 km (XNUMX XNUMX vt.) oor SMF
100G ER4-module, QSFP28-vormfaktor, Duplex LC, 1310 nm, 40 km (131,233.59 100 voet) oor SMF 28G QSFP10 AOC-kabel, 32.81 m (XNUMX voet)
100G QSFP28 AOC-kabel, 5 m (16.40 vt.)

40G BASE-reeks optiese modules
Produk Model

Beskrywing

40G-QSFP-SR-MM850 40G-QSFP-LR4-SM1310 40G-QSFP-LSR-MM850 40G-QSFP-iLR4-SM1310

40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF 40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF 40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF 40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF

40G-QSFP-LX4-SM1310 40G-AOC-30M 40G-AOC-5M

40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF 40G QSFP+ AOC cable, 30 m (98.43 ft.)
40G QSFP+ AOC cable, 5 m (16.40 ft.)

Netwerkskakelaar.com

10

25G BASE-reeks optiese modules
Produk Model

Beskrywing

VG-SFP-AOC5M VG-SFP-LR-SM1310 VG-SFP-SR-MM850

25G SFP28 AOC cable, 5 m (16.40 ft.) 25G LR module, SFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF 25G SR module, SFP28 form factor, Duplex LC, 850 nm, 100 m (328.08 ft.) over MMF

10G BASE-reeks optiese modules
Produk Model

Beskrywing

XG-LR-SM1310 XG-SR-MM850 XG-SFP-AOC1M XG-SFP-AOC3M

10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF 10G SFP+ AOC cable, 1 m (3.28 ft.) 10G SFP+ AOC cable, 3 m (9.84 ft.)

XG-SFP-AOC5M XG-SFP-SR-MM850 XG-SFP-LR-SM1310 XG-SFP-ER-SM1550 XG-SFP-ZR-SM1550

10G SFP+ AOC cable, 5 m (16.40 ft.) 10G SR module, SFP+ form factor, Duplex LC, 300 m (984.25 ft.) over MMF 10G LR module, SFP+ form factor, Duplex LC, 10 km ((32,808.40 ft.) over SMF 10G ER module, SFP+ form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF 10G ZR module, SFP+ form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

1000M BASE Series Optical Modules
Produk Model

Beskrywing

GE-SFP-LH40-SM1310-BIDI GE-SFP-LX20-SM1310-BIDI GE-SFP-LX20-SM1550-BIDI

1G LH module, SFP form factor, BIDI LC, 40 km (131,233.60 ft.) over SMF 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF 1G LX module, SFP form factor, BIDI LC, 20 km (65,616.80 ft.) over SMF

Netwerkskakelaar.com

11

MINI-GBIC-LH40-SM1310 MINI-GBIC-LX-SM1310 MINI-GBIC-SX-MM850 MINI-GBIC-ZX80-SM1550

1G LH module, SFP form factor, Duplex LC, 40 km (131,233.60 ft.) over SMF 1G LX module, SFP form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF 1G SR module, SFP form factor, Duplex LC, 550 m (1,804.46 ft.) over MMF 1G ZX module, SFP form factor, Duplex LC, 80 km (262,467.19 ft.) over SMF

1000M BASE Series Electrical Modules
Produk Model

Beskrywing

Mini-GBIC-GT(F) Mini-GBIC-GT

1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a 1G SFP copper module, SFP form factor, RJ45, 100 m (328.08 ft.) over Cat 5e/6/6a

Netwerkskakelaar.com

12

Dokumente / Hulpbronne

Ruijie-networks RG-S6510 Series Data Center Access Switch [pdf] Instruksiehandleiding
RG-S6510-48VS8CQ, RG-S6510-32CQ, RG-S6510 Series Data Center Access Switch, RG-S6510 Series, Data Center Access Switch, Center Access Switch, Access Switch

Verwysings

Los 'n opmerking

Jou e-posadres sal nie gepubliseer word nie. Vereiste velde is gemerk *