INTERFACE003 – Y-Connect Module
Specifikacije in navodila za namestitev

INTERFACE003 Y Connect Module

FALL SAFE 50 7003 G1 Osebna zaščitna oprema - ikona 12 OPOZORILO
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS:

  1. PREBERITE IN UPOŠTEVAJTE VSA NAVODILA ZA NAMESTITEV.
  2. Always shut OFF the main power before performing any electrical intervention.
  3. Photoelectric cells must be installed facing each other across the door’s path within 6” (15 cm) of the plane of the door and the beam no more than 5-3/4” (14,6 cm) above the floor.

Komponente in specifikacije

INTERFACE003 is a Y-Connect signal merging unit which allows for the connection of any two (2) Independent External Entrapment Protection Devices onto the MONITORED inputs of the operator’s Electronic Control Board BOARD070M. With INTERFACE003 properly installed, the operator receives an obstruction signal when either or both of the devices sense an obstruction. When no obstruction is present, INTERFACE003 passes the standard dynamic signal to the operator. Refer to the Connections section on p.2 for further instructions.

Tehnične specifikacije

Zaščitni razred Nema 4
Material ohišja ABS/PA6 GF30; TPE
Dimenzije ohišja 3” L x 1-9/16” W x 1/2” H
Delovna temperatura -13 ° F do 167 ° F (-25 ° C do 75 ° C)
Dobava Voltage 24 VAC/DC
Poraba energije < 15 mA
Odzivni čas 33 ms obstruction time with secondary device

Manaras INTERFACE003 Y Connect Module - Fig 1

Manaras INTERFACE003 Y Connect Module - Fig 2

LED Stanje Opis
RUMENA
ZELENA
Manaras INTERFACE003 Y Connect Module - Symbol 1 VKLOP
No Signal / Obstruction
RUMENA
ZELENA
Manaras INTERFACE003 Y Connect Module - Symbol 2 VKLOP
Normalno delovanje
RUMENA
ZELENA
Manaras INTERFACE003 Y Connect Module - Symbol 3 IZKLOP
IZKLOP

Manaras INTERFACE003 Y Connect Module - Fig 3

Povezave

Connect ANY TWO (2) independent UL 325 listed Monitored Entrapment Protection Devices simultaneously to the specific MONIT Terminals #15 and #16 on the Electronic Control Board BOARD 070M. Compatible devices include:

  • Photo Electric Cells: PHOTO061/065/070
  • Non-Contact Sensing Edges: PHOTO068A/068C
  • Electric Sensing Edges: SENSEDGE007UM/018UM/044UM
  • Light Curtains: LIGHTCURTAIN001/002

Opomba:

  • Never install TWO sets of photo electric cells within 45” of each other.
  • To limit the cross talk between two sets of photo electric cells, alternate the position of the Transmitter and Receiver, such that, on the same side of the door there is a Transmitter from set #1 and a Receiver from set #2.
  • An additional interface module may be required (INTERFACE002) when an electric sensing edge is used as one of the two Monitored Entrapment Protection Devices.

Manaras INTERFACE003 Y Connect Module - Fig 4

Za več informacij obiščite www.devancocanada.com ali pokličite brezplačno na 855-931-3334