INTERFACE003 – Y-Connect Module
Specifications and Installation Instructions

INTERFACE003 Y Connect Module

FALL SAFE 50 7003 G1 Personal Protection Equipment - icon 12 WARNING
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS:

  1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
  2. Always shut OFF the main power before performing any electrical intervention.
  3. Photoelectric cells must be installed facing each other across the door’s path within 6” (15 cm) of the plane of the door and the beam no more than 5-3/4” (14,6 cm) above the floor.

Components and Specifications

INTERFACE003 is a Y-Connect signal merging unit which allows for the connection of any two (2) Independent External Entrapment Protection Devices onto the MONITORED inputs of the operator’s Electronic Control Board BOARD070M. With INTERFACE003 properly installed, the operator receives an obstruction signal when either or both of the devices sense an obstruction. When no obstruction is present, INTERFACE003 passes the standard dynamic signal to the operator. Refer to the Connections section on p.2 for further instructions.

Technical Specifications

Protection Class Nema 4
Housing Material ABS/PA6 GF30; TPE
Housing Dimensions 3” L x 1-9/16” W x 1/2” H
Operation Temperature -13 °F to 167 °F (-25 °C to 75°C)
Supply Voltage 24 VAC/DC
Power Consumption < 15 mA
Response Time 33 ms obstruction time with secondary device

Manaras INTERFACE003 Y Connect Module - Fig 1

Manaras INTERFACE003 Y Connect Module - Fig 2

LED Status Description
YELLOW
GREEN
Manaras INTERFACE003 Y Connect Module - Symbol 1 Power ON
No Signal / Obstruction
YELLOW
GREEN
Manaras INTERFACE003 Y Connect Module - Symbol 2 Power ON
Normal Operation
YELLOW
GREEN
Manaras INTERFACE003 Y Connect Module - Symbol 3 Power OFF
Power OFF

Manaras INTERFACE003 Y Connect Module - Fig 3

Connections

Connect ANY TWO (2) independent UL 325 listed Monitored Entrapment Protection Devices simultaneously to the specific MONIT Terminals #15 and #16 on the Electronic Control Board BOARD 070M. Compatible devices include:

  • Photo Electric Cells: PHOTO061/065/070
  • Non-Contact Sensing Edges: PHOTO068A/068C
  • Electric Sensing Edges: SENSEDGE007UM/018UM/044UM
  • Light Curtains: LIGHTCURTAIN001/002

Note:

  • Never install TWO sets of photo electric cells within 45” of each other.
  • To limit the cross talk between two sets of photo electric cells, alternate the position of the Transmitter and Receiver, such that, on the same side of the door there is a Transmitter from set #1 and a Receiver from set #2.
  • An additional interface module may be required (INTERFACE002) when an electric sensing edge is used as one of the two Monitored Entrapment Protection Devices.

Manaras INTERFACE003 Y Connect Module - Fig 4

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334