INTERFACE003 – Y-Connect Module
Malangizo ndi Kuyika Malangizo

INTERFACE003 Y Lumikizani Module

FALL SAFE 50 7003 G1 Personal Protection Equipment - chithunzi 12 CHENJEZO
KUCHEPETSA KUCHITIKA KWA WOvulala KAPENA KUIFA KWA ANTHU:

  1. WERENGANI NDIKUTSATIRA MALANGIZO ONSE OYANG'ANIRA.
  2. Always shut OFF the main power before performing any electrical intervention.
  3. Photoelectric cells must be installed facing each other across the door’s path within 6” (15 cm) of the plane of the door and the beam no more than 5-3/4” (14,6 cm) above the floor.

Zigawo ndi Mafotokozedwe

INTERFACE003 is a Y-Connect signal merging unit which allows for the connection of any two (2) Independent External Entrapment Protection Devices onto the MONITORED inputs of the operator’s Electronic Control Board BOARD070M. With INTERFACE003 properly installed, the operator receives an obstruction signal when either or both of the devices sense an obstruction. When no obstruction is present, INTERFACE003 passes the standard dynamic signal to the operator. Refer to the Connections section on p.2 for further instructions.

Mfundo Zaukadaulo

Gulu la Chitetezo Nema 4
Zida Zanyumba ABS/PA6 GF30; TPE
Makulidwe a Nyumba 3” L x 1-9/16” W x 1/2” H
Kutentha kwa Ntchito -13 ° F mpaka 167 ° F (-25 ° C mpaka 75 ° C)
Wonjezerani Voltage 24 VAC / DC
Kugwiritsa Ntchito Mphamvu <15 mA
Nthawi Yoyankha 33 ms obstruction time with secondary device

Manaras INTERFACE003 Y Connect Module - Fig 1

Manaras INTERFACE003 Y Connect Module - Fig 2

LED Mkhalidwe Kufotokozera
CHIYELO
ZOGIRIRA
Manaras INTERFACE003 Y Connect Module - Symbol 1 Yatsani
No Signal / Obstruction
CHIYELO
ZOGIRIRA
Manaras INTERFACE003 Y Connect Module - Symbol 2 Yatsani
Normal Operation
CHIYELO
ZOGIRIRA
Manaras INTERFACE003 Y Connect Module - Symbol 3 ZIMALITSA
ZIMALITSA

Manaras INTERFACE003 Y Connect Module - Fig 3

Kulumikizana

Connect ANY TWO (2) independent UL 325 listed Monitored Entrapment Protection Devices simultaneously to the specific MONIT Terminals #15 and #16 on the Electronic Control Board BOARD 070M. Compatible devices include:

  • Photo Electric Cells: PHOTO061/065/070
  • Non-Contact Sensing Edges: PHOTO068A/068C
  • Electric Sensing Edges: SENSEDGE007UM/018UM/044UM
  • Light Curtains: LIGHTCURTAIN001/002

Zindikirani:

  • Never install TWO sets of photo electric cells within 45” of each other.
  • To limit the cross talk between two sets of photo electric cells, alternate the position of the Transmitter and Receiver, such that, on the same side of the door there is a Transmitter from set #1 and a Receiver from set #2.
  • An additional interface module may be required (INTERFACE002) when an electric sensing edge is used as one of the two Monitored Entrapment Protection Devices.

Manaras INTERFACE003 Y Connect Module - Fig 4

Kuti mudziwe zambiri, chonde pitani www.devancocanada.com kapena imbani foni yaulere pa 855-931-3334

Zolemba / Zothandizira

Manaras INTERFACE003 Y Connect Module [pdf] Kukhazikitsa Guide
INTERFACE003, INTERFACE003 Y Connect Module, INTERFACE003, Y Connect Module, Connect Module

Maumboni

Siyani ndemanga

Imelo yanu sisindikizidwa. Minda yofunikira yalembedwa *