INTERFACE003 – Y-Connect Module
વિશિષ્ટતાઓ અને સ્થાપન સૂચનાઓ

INTERFACE003 Y કનેક્ટ મોડ્યુલ

FALL SAFE 50 7003 G1 પર્સનલ પ્રોટેક્શન ઇક્વિપમેન્ટ - આઇકન 12 ચેતવણી
વ્યક્તિઓને ગંભીર ઈજા કે મૃત્યુનું જોખમ ઘટાડવા માટે:

  1. બધી ઇન્સ્ટોલેશન સૂચનાઓ વાંચો અને અનુસરો.
  2. Always shut OFF the main power before performing any electrical intervention.
  3. Photoelectric cells must be installed facing each other across the door’s path within 6” (15 cm) of the plane of the door and the beam no more than 5-3/4” (14,6 cm) above the floor.

ઘટકો અને વિશિષ્ટતાઓ

INTERFACE003 is a Y-Connect signal merging unit which allows for the connection of any two (2) Independent External Entrapment Protection Devices onto the MONITORED inputs of the operator’s Electronic Control Board BOARD070M. With INTERFACE003 properly installed, the operator receives an obstruction signal when either or both of the devices sense an obstruction. When no obstruction is present, INTERFACE003 passes the standard dynamic signal to the operator. Refer to the Connections section on p.2 for further instructions.

ટેકનિકલ વિશિષ્ટતાઓ

રક્ષણ વર્ગ નેમા 4
હાઉસિંગ સામગ્રી ABS/PA6 GF30; TPE
હાઉસિંગ પરિમાણો 3” L x 1-9/16” W x 1/2” H
ઓપરેશન તાપમાન -13 ° F થી 167 ° F (-25 ° C થી 75 ° C)
પુરવઠો ભાગtage 24 VAC/DC
પાવર વપરાશ < 15 mA
પ્રતિભાવ સમય 33 ms obstruction time with secondary device

Manaras INTERFACE003 Y Connect Module - Fig 1

Manaras INTERFACE003 Y Connect Module - Fig 2

એલઇડી સ્થિતિ વર્ણન
પીળો
લીલો
Manaras INTERFACE003 Y Connect Module - Symbol 1 પાવર ચાલુ
No Signal / Obstruction
પીળો
લીલો
Manaras INTERFACE003 Y Connect Module - Symbol 2 પાવર ચાલુ
સામાન્ય કામગીરી
પીળો
લીલો
Manaras INTERFACE003 Y Connect Module - Symbol 3 પાવર બંધ
પાવર બંધ

Manaras INTERFACE003 Y Connect Module - Fig 3

જોડાણો

Connect ANY TWO (2) independent UL 325 listed Monitored Entrapment Protection Devices simultaneously to the specific MONIT Terminals #15 and #16 on the Electronic Control Board BOARD 070M. Compatible devices include:

  • Photo Electric Cells: PHOTO061/065/070
  • Non-Contact Sensing Edges: PHOTO068A/068C
  • Electric Sensing Edges: SENSEDGE007UM/018UM/044UM
  • Light Curtains: LIGHTCURTAIN001/002

નોંધ:

  • Never install TWO sets of photo electric cells within 45” of each other.
  • To limit the cross talk between two sets of photo electric cells, alternate the position of the Transmitter and Receiver, such that, on the same side of the door there is a Transmitter from set #1 and a Receiver from set #2.
  • An additional interface module may be required (INTERFACE002) when an electric sensing edge is used as one of the two Monitored Entrapment Protection Devices.

Manaras INTERFACE003 Y Connect Module - Fig 4

વધુ માહિતી માટે, કૃપા કરીને મુલાકાત લો www.devancocanada.com અથવા ટોલ ફ્રી પર કૉલ કરો 855-931-3334

દસ્તાવેજો / સંસાધનો

Manaras INTERFACE003 Y Connect Module [પીડીએફ] સ્થાપન માર્ગદર્શિકા
INTERFACE003, INTERFACE003 Y Connect Module, INTERFACE003, Y Connect Module, Connect Module